Drive system
|
SINAMICS S120
|
|
Electronics power supply
|
24 V DC, -15%/+20%
|
|
Vibratory load
|
|
- Transport 1) acc. to EN 60721-3-2
|
|
- All units and components except for chassis format
|
Class 2M3
|
|
|
Class 2M2
|
- Operation
Test values acc. to EN 60068?2?6
|
Test Fc
|
|
|
10 ... 58 Hz: Constant deflection, 0.075 mm (0.003 in)
58 ... 150 Hz: Constant acceleration = 9.81 m/s2 (3.2 ft/s2) (1 ? g)
|
|
Shock load
|
|
- Transport1) acc. to EN 60721-3-2
|
|
- All units and components except for chassis format
|
Class 2M3
|
|
|
Class 2M2
|
- Operation
Test values acc. to EN 60068?2?27
|
Test Ea
|
- Booksize and blocksize formats FSA to FSB
|
147 m/s2 (482 ft/s2) (15 ? g)/11 ms
|
- Blocksize format FSC to FSF
|
49 m/s2 (161 ft/s2) (5 ? g)/30 ms
|
|
|
98 m/s2 (321 ft/s2) (10 ? g)/20 ms
|
|
Ambient conditions
|
|
- Protection class according to EN 61800?5?1
|
Class I (with protective conductor system) and Class III (PELV)
|
|
|
DIN VDE 0106 Part 100 and BGV A 3 when used properly
|
|
|
Internal/external air cooling, power units with increased air cooling by means of built-in fan
|
|
Permissible ambient/coolant temperature (air) during operation
|
|
- For line-side components, Power Modules, Line Modules and Motor Modules
|
0 ... 40 °C (32 ... 104 °F) without derating, > 40 ... 55 °C (104 ... 131 °F), see derating characteristics
|
- For Control Units, supplementary system components, DC link components and Sensor Modules
|
0 … 55 °C (32 … 131 °F) up to 2000 m (6562 ft) above sea level
|
|
Climatic ambient conditions
|
|
- Storage1) acc. to EN 60721?3?1
|
Class 1K4 Temperature -25 ... +70 °C (-13 ... +158 °F)
|
- Transport1) acc. to EN 60721-3-2
|
Class 2K4 Temperature -40 … +70 °C (-40 ... +158 °F) Max. air humidity 95 % at 40 °C (104 °F)
|
- Operation according to EN 60721?3?3
|
Class 3K3 Temperature 0 ... 55 °C (32 ... 131 °F) Condensation, splashwater and ice formation are not permitted (EN 60204, Part 1)
|
|
Environmental class/harmful chemical substances
|
|
- Storage1) acc. to EN 60721?3?1
|
Class 1C2
|
- Transport1) acc. to EN 60721-3-2
|
Class 2C2
|
- Operation according to EN 60721?3?3
|
Class 3C2
|
|
Organic/biological influences
|
|
- Storage1) acc. to EN 60721?3?1
|
Class 1B1
|
- Transport1) acc. to EN 60721-3-2
|
Class 2B1
|
- Operation according to EN 60721?3?3
|
Class 3B1
|
|
Degree of contamination
According to EN 61800?5?1
|
2
|