Requirements for pipes | |
Size | FUS060: DN 100 … DN 3000 (4” … 120”) FUS080: DN 100 … DN 1200 (4” … 48”) |
Line pressure | max. 40 bar (580 psi) |
Media temperature | |
| -10 … +200 °C (14 … 392 °F) |
- ATEX Ex d version (FUS060)
| -20 … +180 °C (-4 … +356 °F) |
- ATEX Ex i version (FUS060)
| -10 … +190 °C (14 … 374 °F) |
Ambient temperature sensor | |
- Standard and Ex-i version
| -20 … +60 °C (-4 … +140 °F) |
| -20 … +180 °C (-4 … +356 °F) |
Transducer enclosure/approvals/certificates | |
Standard version | IP67 (NEMA 6)/IP68 (NEMA 6P) |
Ex approval | System ATEX approval for SONO 3200 Ex i transducers together with transmitter FUS060-Ex: ATEX II 2 G Ex dem [ia/Ib] IIC T6/T4/T3 Gb or |
ATEX II 2G Ex d T3-T6 Gb with SONO 3200 Ex d transducers (for standard FUS060 transmitter, installed outside of Ex zone) |
Material certificates | EN 10204-3.1 material certificate on transducer mounting parts |
Transducer materials | |
Terminal housing | Standard version: PA 6.6, 100 °C (212 °F) or stainless steel AISI 316, 200 °C (392 °F) |
Transducer body | Standard version: Stainless steel AISI 316, 200 °C (392 °F) |
Materials of existing pipeline | |
Steel | Transducer holder: EN 10273 or EN 10216 (P235GH) |
| | Mounting plates 1): EN 10273 or EN 10216 (P235GH) |
Concrete | Transducer holder: Stainless steel AISI 316 or similar |
| | Mounting plates 1): (not included) |
Stainless steel | Transducer holder: Stainless steel AISI 316 or similar |
| | Mounting plates 1): Stainless steel AISI 316 or similar |
Pipe wall thickness | |
Steel pipe (AISI 316 and St. 37.2 or corresponding material) | Transducer and holder available in length L = 160, allowing a pipe wall thickness up to 20 mm (0.79”) |
Concrete pipe | Transducer and holder available in length L = 230, allowing a pipe wall thickness up to 200 mm (7.9”) and pipe sizes ? DN 600. |
Dimension of the package box | 856 x 390 x 344 mm (33.7“ x 15.4“ x 13.5“) |
(L x W x H) |
Weight example of a package | approx. 53 kg (116.8 lb) |
(standard 2-path with FUS060) |
Certificates and approvals | |
Conformity certificate | The devices are supplied as standard with a Siemens Certificate of Conformity on a DVD. |
Material certificate | Material certificate for the transducer parts according to EN 10204-3.1 is optionally available. |
Approvals | No custody transfer approvals |