product brand name | | SIPLUS |
Product designation | | HCS3200 fan, IP65, 9 output channels, fan output | HCS3200, IP65, 9 output channels |
General technical data: | | | |
Control version / of heat emitters | | Half-wave control |
Type of load | | Ohmic load |
Equipment marking / acc. to DIN EN 81346-2 | | Q |
Degree of pollution | | 2 |
Certificates/ approvals: | | | |
Certificate of suitability | | CE | CE, UL |
Power supply: | | | |
Type of voltage / of the supply voltage | | AC |
Supply voltage / with AC / Rated value | V | 400 |
Relative negative tolerance / of the supply voltage | % | 10 |
Relative positive tolerance / of the supply voltage | % | 10 |
Supply voltage frequency | | | |
| Hz | 50 |
| Hz | 60 |
Relative symmetrical tolerance / of the supply voltage frequency | % | 5 |
Switching capacity current / per phase / maximum | A | 63 |
Maximum short-circuit current breaking capacity (Icu) / at 400 V / Rated value | kA | 25 |
Design of the electrical isolation | | Optocoupler between main circuit and PELV |
Power capacity / maximum permissible | kW | 25.2 |
Type of electrical connection / for supply voltage | | Connector, 4-pole + PE | Connector, 2-pole + PE |
Type of connectable conductor cross-section | | | |
| | 3x (6 ... 25 mm?) and 1x PE (6 ... 16 mm?) | 2x (6 ... 25 mm?) and 1x PE (6 ... 16 mm?) |
| | 3x (8 ... 4) | 2x (8 ... 4) |
Power Electronics: | | | |
Number of outputs / for heating power | | 9 |
Number of heat emitters / per output / maximum | | 1 |
Output voltage / at output / for heating power | V | 400 |
Power capacity / per output | W | 200 ... 4 000 |
Output current / at output / for heating power / Rated value | A | 10 |
Design of short-circuit protection / for heating power / per output | | Fuse 16 A | Fuse 15 A |
Galvanic isolation / between the outputs | | No |
Number of outputs / for fan | | 1 | 0 |
Output voltage / at output / for fan | V | 230 | |
Power capacity / for fan / per output | W | 60 ... 500 | - |
Design of short-circuit protection / at output / for fan | | Safety fuse 4 A | |
Type of electrical connection / at output / for heating and fan | | Connector, 20-pole + PE |
Type of connectable conductor cross-section | | | |
| | 20x (1.5 ... 4 mm?), 1x PE (1.5 ... 16 mm?) | 18x (1.5 ... 4 mm?), 1x PE (1.5 ... 16 mm?) |
| | 20x (18 ... 12) | 18x (18 ... 12) |
Product function / voltage detection | | Yes |
Communication: | | | |
Protocol / is supported / PROFIBUS DP protocol | | Yes |
Design of the interface | | PROFIBUS DP |
Transfer rate / with PROFIBUS DP / maximum | Mbit/s | 12 |
Type of electrical connection / of the PROFIBUS interface | | ECOFAST |
Power supply: | | | |
Design of the power supply | | External |
Type of voltage | | DC |
Supply voltage / for electronics | V | 24 |
Relative symmetrical tolerance / of the input voltage | % | 20 |
Consumed current / for electronics / maximum | A | 0.25 |
Protective and monitoring functions: | | | |
Number of status displays | | 2 |
Display version / as status display by LED | | LED green = status indicator, LED red = fault indicator |
Product function / Temperature monitoring | | Yes |
Type of the temperature monitoring | | NTC thermistor |
Diagnostics function / Tripped fuse | | Yes |
Diagnostics function / Cable break | | Yes |
Diagnostics function / Heat emitter failure | | Yes |
Mechanical data: | | | |
mounting position | | vertical |
Mounting type | | screw fixing |
Type of ventilation | | Self-ventilation |
Shock resistance | | | |
| | 15g / 11 ms / 3 shocks / axis |
| | 25 g / 6 ms / 1000 shocks / axis |
Vibration resistance | | | |
| | 10 ... 58 Hz / 0.15 mm, 58 ... 150 Hz / 1g |
| | 5 ... 9 Hz / 3.5 mm, 9 ... 500 Hz / 1g |
Protection class IP | | IP65 |
Width | mm | 300 |
Height | mm | 380 |
Depth | mm | 200 |
Electromagnetic compatibility: | | | |
Conducted interference / due to burst / acc. to IEC 61000-4-4 | | 2 kV power supply lines / 1 kV signal lines |
Conducted interference / due to surge / acc. to IEC 61000-4-5 | | On supply lines: 1 kV symmetrical, 2 kV asymmetrical, (24 V DC supply only with external protective measure) for PROFIBUS cable : asymmetrical 1 kV |
Conducted interference / due to high-frequency radiation / acc. to IEC 61000-4-6 | | 10 V (0.15 ... 80 MHz) |
Electrostatic discharge / acc. to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / acc. to IEC 61000-4-3 | | 10 V/m (80 ... 1000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz) |
EMC emitted interference | | in accordance with IEC 61000-6-4:2007 + A1:2011 |
Overvoltage category | | III |
Ambient conditions: | | | |
Ambient temperature | | | |
| °C | 0 ... 50 |
| °C | -40 ... +70 |
| °C | -40 ... +70 |
Air pressure | | | |
| hPa | 860 ... 1 080 |
| hPa | 660 ... 1 080 |
Installation altitude / at height above sea level / maximum | m | 2 000 |
Relative humidity | | | |
| % | 95 |
| % | 50 |