Current demand (X524 at 24 V DC) without DRIVE-CliQ supply | 0.2 A |
- Conductor cross-section, max.
| 2.5 mm2 |
| 20 A |
Max. current demand ext. 24 V for supplying the digital outputs and 24 V sensor supply (X514 at 24 V DC) | 4 A |
- Conductor cross-section, max.
| 2.5 mm2 |
| 20 A |
I/O devices | |
- Number of fail-safe digital in
| 10 |
- Number of fail-safe digital outputs
| 4 |
| 3, of which 2 can be internally shut down to dynamize fail-safe digital inputs, current carrying capacity of input is 0.5 A |
| Plug-in screw-type terminals |
- Conductor cross-section, max.
| 1.5 mm2 |
Digital inputs According to IEC 61131-2 Type 1, with electrical isolation | |
| -3 … +30 V |
- Low level
(an open digital input is interpreted as "low")
| -3 … +5 V |
| 15 … 30 V |
- Current consumption at 24 V DC, typ.
| > 2 mA |
- Delay time of digital inputs, approx. 1)
| |
| 30 ?s |
| 60 ?s |
| Low level (for inputs that can be inverted: without inversion) |
Digital outputs Continuously short-circuit proof | |
| 24 V DC |
- Load current per fail-safe digital output, max. 2)
| 0.5 A |
- Delay times (resistive load) 1)
| |
| 300 ?s |
| 350 ?s |
| Output switched off |
Scanning cycle tSI for fail-safe digital inputs or fail-safe digital outputs | 4 ... 25 ms (adjustable) |
PE connection | M4 screw |
Dimensions | |
| 50 mm |
| 150 mm |
| 111 mm |
Weight, approx. | 0.9 kg |
Conformity | CE |
Approvals, according to | cULus |
Safety Integrated | Safety Integrity Level 2 (SIL2) acc. to IEC 61508, Performance Level d (PLd) acc. to ISO 13849-1 and Control Category 3 acc. to EN SO 13849-1 (previously EN 954-1) |