Recommended line-side system components Appropriate line-side power components are assigned depending on the power rating of the Power Modules, Basic Line Modules, Smart Line Modules or Active Line Modules
Further information about the line contactors, switch disconnectors, fuses and circuit breakers is provided in the Catalogs IC 10 and LV 10.1.
Assignment of line-side power components to air-cooled and liquid-cooled Power Modules, chassis format Type rating at 400 V
Rated input current
Suitable for Power Modules, chassis format
Main contactor
Switch disconnector without handle and shaft
Switch disconnector with handle and shaft
Air-cooled
Liquid-cooled
kW
A
A
6SL3310-... 6SL3315-... 1) 2)
Order No.
Order No.
Order No.
Line voltage 380 ... 480 V 3 AC
110
229
230
1TE32-1AA3
3RT1064-6AP36
3KL5530-1AB01
3KL5530-1GB01
132
284
285
1TE32-6AA3
3RT1065-6AP36
3KL5730-1AB01
3KL5730-1GB01
160
338
340
1TE33-1AA3
3RT1066-6AP36
–
200
395
–
1TE33-8AA3
3RT1075-6AP36
–
250
509
540
1TE35-0AA3
3RT1076-6AP36
3KL6130-1AB02
3KL6130-1GB02
1) 6SL3310-… is the air-cooled version.
2) 6SL3315-… is the liquid-cooled version.
Type rating at 400 V
Rated input current
Suitable for Power Modules, chassis format
Cable protection fuse
Cable protection fuse incl. semiconductor protection
Air-cooled
Liquid-cooled
Rated current
Rated current
kW
A
A
6SL3310-... 6SL3315-... 1) 2)
Order No.
A
Order No.
A
Line voltage 380 ... 480 V 3 AC
110
229
230
1TE32-1AA3
3NA3144
250
3NE1230-2
315
132
284
285
1TE32-6AA3
3NA3250
300
3NE1331-2
350
160
338
340
1TE33-1AA3
3NA3254
355
3NE1333-2
450
200
395
–
1TE33-8AA3
3NA3260
400
250
509
540
1TE35-0AA3
3NA3372
630
3NE1230?2 or 3NE1436?2
2 ? 315/630
1) 6SL3310-… is the air-cooled version.
2) 6SL3315-… is the liquid-cooled version.
Assignment of line-side power components to air-cooled and liquid-cooled Basic Line Modules, chassis format Rated power at 400 V or 690 V
Rated input current
Suitable for Basic Line Module
Main contactor
Fixed-mounted circuit breaker
Switch disconnector without handle and shaft
Switch disconnector with handle and shaft
kW
A
Order No.
Order No.
Order No.
Order No.
Line voltage 380 ... 480 V 3 AC
200
365
6SL3330-1TE34-2AA3 1)
3RT1075-...
–
3KL6130-1AB02
3KL6130-1GB02
250
460
6SL3330-1TE35-3AA3 1)
3RT1076-...
–
3KL6130-1AB02
3KL6130-1GB02
360
610
6SL3335-1TE37-4AA3 2)
3RT1076-...
–
3KL6130-1AB02
3KL6130-1GB02
400
710
6SL3330-1TE38-2AA3 1)
3RT1066-...
(3 units)
–
3KL6230-1AB02
3KL6230-1GB02
560
1010
6SL3330-1TE41-2AA3 1)
–
3WL1112-2BB34-4AN2-Z C22
–
–
600
1000
6SL3335-1TE41-2AA3 2)
–
3WL1112-2BB34-4AN2-Z C22
–
–
710
1265
6SL3330-1TE41-5AA3 1)
–
3WL1116-2BB34-4AN2-Z C22
–
–
830
1420
6SL3335-1TE41-7AA3 2)
–
3WL1116-2BB34-4AN2-Z C22
–
–
Line voltage 500 ... 690 V 3 AC
250
260
6SL3330-1TG33-0AA3 1)
3RT1066-...
–
3KL5730-1AB01
3KL5730-1GB01
355
375
6SL3330-1TG34-3AA3 1)
3RT1075-…
–
3KL6130-1AB02
3KL6130-1GB02
340
6SL3335-1TG34-2AA3 2)
560
575
6SL3330-1TG36-8AA3 1)
3RT1076-…
–
3KL6130-1AB02
3KL6130-1GB02
630
600
6SL3335-1TG37-3AA3 2)
3RT1076-…
–
3KL6130-1AB02
3KL6130-1GB02
900
925
6SL3330-1TG41-1AA3 1)
–
3WL1210-4BB34-4AN2-Z C22
–
–
1100
1180
6SL3330-1TG41-4AA3 1)
–
3WL1212-4BB34-4AN2-Z C22
–
–
1070
6SL3335-1TG41-3AA3 2)
1370
1350
6SL3335-1TG41-7AA3 2)
–
3WL1216-4BB34-4AN2-Z C22
–
–
1) 6SL3330-… is the air-cooled version.
2) 6SL3335-… is the liquid-cooled version.
Rated power at 400 V or 690 V
Rated input current
Suitable for Basic Line Module
Cable protection fuse
Cable protection fuse
incl. semiconductor protection
Rated current
Rated current
kW
A
Order No.
A
Order No.
A
Line voltage 380 ... 480 V 3 AC
200
365
6SL3330-1TE34-2AA3 1)
3NA3365
500
3NE1333?2
450
250
460
6SL3330-1TE35-3AA3 1)
3NA3372
630
3NE1334?2
500
360
610
6SL3335-1TE37-4AA3 2)
3NA3352
(2 units)
2 ? 315
3NE1333-2
(2 units)
2 ? 450
400
710
6SL3330-1TE38-2AA3 1)
3NA3475
800
3NE1438-2 3)
800
560
1010
6SL3330-1TE41-2AA3 1)
3NA3482
1250
3NE1435-2
(2 units)
2 ? 560
600
1000
6SL3335-1TE41-2AA3 2)
3NA3365
(2 units)
2 ? 500
3NE1435-2
(2 units)
2 ? 560
710
1265
6SL3330-1TE41-5AA3 1)
3NA3475
(2 units)
2 ? 800
3NE1437-2
(2 units)
2 ? 710
830
1420
6SL3335-1TE41-7AA3 2)
3NA3365
(3 units)
3 ? 500
3NE1438-2
(2 units)
2 ? 800
Line voltage 500 ... 690 V 3 AC
250
260
6SL3330-1TG33?0AA3 1)
3NA3252-6
315
3NE1230-2
315
355
375
6SL3330-1TG34?3AA3 1)
3NA3365-6
500
3NE1333-2 3)
450
340
6SL3335-1TG34?2AA3 2)
3NA3354-6
355
560
575
6SL3330-1TG36?8AA3 1)
3NA3252-6
(2 units)
2 ? 315
3NE1436-2 3)
630
630
600
6SL3335-1TG37-3AA3 2)
3NA3250-6
(2 units)
2 ? 300
3NE1331-2
(2 units)
2 ? 350
900
925
6SL3330-1TG41-1AA3 1)
3NA3365-6
(2 units)
2 ? 500
3NE1334-2
(2 units)
2 ? 500
1100
1180
6SL3330-1TG41-4AA3 1)
3NA3365-6
(3 units)
3 ? 500
3NE1436-2 3)
(2 units)
2 ? 630
1070
6SL3335-1TG41?3AA3 2)
3NA3360-6
(3 units)
3 ? 400
3NE1447-2
(2 units)
2 ? 670
1370
1350
6SL3335-1TG41?7AA3 2)
3NA3365-6
(3 units)
3 ? 500
3NE1435-2
(3 units)
3 ? 560
1) 6SL3330-… is the air-cooled version.
2) 6SL3335-… is the liquid-cooled version.
3) No semiconductor protection.
Assignment of line-side power components to Smart Line Modules, chassis format Rated power at 400 V or 690 V
Rated input current
Suitable for Smart Line Module
Main contactor
Fixed-mounted circuit breaker
Switch disconnector without handle and shaft
Switch disconnector with handle and shaft
kW
A
6SL3330-...
Order No.
Order No.
Order No.
Order No.
Line voltage 380 ... 480 V 3 AC
250
463
6TE35-5AA3
3RT1476-6AP36
–
3KL6130-1AB02
3KL6130-1GB02
355
614
6TE37-3AA3
3RT1476-6AP36
–
3KL6230-1AB02
3KL6230-1GB02
500
883
6TE41-1AA3
–
3WL1210-4CB34-4AN2-Z C22
–
–
630
1093
6TE41-3AA3
–
3WL1212-4CB34-4AN2-Z C22
–
–
800
1430
6TE41-7AA3
–
3WL1216-4CB34-4AN2-Z C22
–
–
Line voltage 500 ... 690 V 3 AC
450
463
6TG35-5AA3
3RT1466-6AP36
–
3KL6130-1AB02
3KL6130-1GB02
710
757
6TG38-8AA3
3RT1466-6AP36
(3 units)
–
3KL6230-1AB02
3KL6230-1GB02
1000
1009
6TG41-2AA3
–
3WL1212-4CB34-4AN2-Z C22
–
–
1400
1430
6TG41-7AA3
–
3WL1216-4CB34-4AN2-Z C22
–
–
Rated power at 400 V or 690 V
Rated input current
Suitable for Smart Line Module
Cable protection fuse
Cable protection fuse incl. semiconductor protection
Rated current
Rated current
kW
A
6SL3330-...
Order No.
A
Order No.
A
Line voltage 380 ... 480 V 3 AC
250
463
6TE35-5AA3
3NA3365
500
3NE1435-2
560
355
614
6TE37-3AA3
3NA3372
630
3NE1437-2
710
500
883
6TE41-1AA3
3NA3480
1000
3NE1334-2
(2 units)
2 ? 500
630
1093
6TE41-3AA3
3NA3482
1250
3NE1436-2
(2 units)
2 ? 630
800
1430
6TE41-7AA3
3NA3475
(2 units)
2 ? 800
3NE1448-2
(2 units)
2 ? 850
Line voltage 500 ... 690 V 3 AC
450
463
6TG35-5AA3
3NA3365-6
500
3NE1435-2
560
710
757
6TG38-8AA3
3NA3360-6
(2 units)
2 ? 400
3NE1448-2
850
1000
1009
6TG41-2AA3
3NA3354-6
(3 units)
3 ? 355
3NE1435-2
(2 units)
2 ? 560
1400
1430
6TG41-7AA3
3NA3365-6
(3 units)
3 ? 500
3NE1448-2
(2 units)
2 ? 850
Assignment of line-side power components to air-cooled and liquid-cooled Active Line Modules or Active Interface Modules, chassis format Rated power at 400 V or 690 V
Rated input current
Suitable for Active Interface Module
Suitable for Active Line Module
Bypass contactor
kW
A
6SL3300-...
Order No.
Line voltage 380 ... 480 V 3 AC
132
210
7TE32-6AA0
6SL3330-7TE32-1AA3
Included in Active Interface Module
160
260
7TE32-6AA0
6SL3330-7TE32-6AA3
Included in Active Interface Module
235
380
7TE33-8AA0
6SL3330-7TE33-8AA3
Included in Active Interface Module
300
490
7TE35-0AA0
6SL3330-7TE35-0AA3 6SL3335-7TE35-0AA3
Included in Active Interface Module
380
605
7TE38-4AA0
6SL3330-7TE36-1AA3
3RT1476-6AP36
500
840
7TE38-4AA0
6SL3330-7TE38-4AA3 6SL3335-7TE38-4AA3
3WL1110-2BB34-4AN2-Z C22
630
985
7TE41-4AA0
6SL3330-7TE41-0AA3
3WL1112-2BB34-4AN2-Z C22
900
1405
7TE41-4AA0
6SL3330-7TE41-4AA3
3WL1116-2BB34-4AN2-Z C22
Line voltage 500 ... 690 V 3 AC
560
575
7TG35-8AA0
6SL3330-7TG35-8AA3 6SL3335-7TG35-8AA3
3RT1476-6AP36
800
735
7TG37-4AA0
6SL3330-7TG37-4AA3
3RT1476-6AP36
(3 units)
1100
1025
7TG41-3AA0
6SL3330-7TG41-0AA3
3WL1212-4BB34-4AN2-Z C22
1400
1270
7TG41-3AA0
6SL3330-7TG41-3AA3 6SL3335-7TG41-3AA3
3WL1216-4BB34-4AN2-Z C22
Rated power at 400 V or 690 V
Rated input current
Suitable for Active Interface Module
Suitable for Active Line Module
Switch disconnector without handle and shaft
Switch disconnector with handle and shaft
Cable protection fuse
Cable protection fuse incl. semiconductor protection
Rated current
Rated current
kW
A
6SL3300-...
6SL3330-... 6SL3335-...
Order No.
Order No.
Order No.
A
Order No.
A
Line voltage 380 ... 480 V 3 AC
132
210
7TE32-6AA0
7TE32-1AA3
3KL5530-1AB01
3KL5530-1GB01
3NA3252
315
3NE1230-2
315
160
260
7TE32-6AA0
7TE32-6AA3
3KL5730-1AB01
3KL5730-1GB01
3NA3254
355
3NE1331-2
350
235
380
7TE33-8AA0
7TE33-8AA3
3KL5730-1AB01
3KL5730-1GB01
3NA3365
500
3NE1334-2
500
300
490
7TE35-0AA0
7TE35-0AA3 7TE35-0AA3 1)
3KL6130-1AB02
3KL6130-1GB02
3NA3372
630
3NE1436-2
630
380
605
7TE38-4AA0
7TE36-1AA3
3KL6230-1AB02
3KL6230-1GB02
3NA3475
800
3NE1438-2
800
500
840
7TE38-4AA0
7TE38-4AA3 7TE38-4AA3 1)
–
–
3NA3362
(2 units)
2 ? 425
3NE1334-2
(2 units)
2 ? 500
630
985
7TE41-4AA0
7TE41-0AA3
–
–
3NA3365
(2 units)
2 ? 500
3NE1436-2
(2 units)
2 ? 630
900
1405
7TE41-4AA0
7TE41-4AA3
–
–
3NA3365
(3 units)
3 ? 500
3NE1448-2
(3 units)
2 ? 850
Line voltage 500 ... 690 V 3 AC
560
575
7TG35-8AA0
7TG35-8AA3 7TG35-8AA3 1)
3KL6130-1AB02
3KL6130-1GB02
3NA3352-6
(2 units)
2 ? 315
3NE1447-2
670
800
735
7TG37-4AA0
7TG37-4AA3
3KL6230-1AB02
3KL6230-1GB02
3NA3360-6
(2 units)
2 ? 400
3NE1448-2
850
1100
1025
7TG41-3AA0
7TG41-0AA3
–
–
3NA3354-6
(3 units)
3 ? 355
3NE1436-2
(2 units)
2 ? 630
1400
1270
7TG41-3AA0
7TG41-3AA3 7TG41-3AA3 1)
–
–
3NA3365-6
(3 units)
3 ? 500
3NE1438-2
(2 units)
2 ? 800
1) Liquid-cooled version, 6SL3335-…