| HART | PROFIBUS PA or Foundation Fieldbus |
Input | |
Measured variable | Gauge pressure |
Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure | Span | Max. perm. test pressure | Rated measuring range | Max. perm. test pressure |
| 0,01 ... 1 bar g (0.15 ... 14.5 psi g) | 6 bar g (87 psi g) | 1 bar g (14.5 psi g) | 6 bar g (87 psi g) |
| 0.04 ... 4 bar g (0.58 ... 58 psi g) | 10 bar g (145 psi g) | 4 bar g (58 psi g) | 10 bar g (145 psi g) |
| 0.16 ... 16 bar g (2.32 ... 232 psi g) | 32 bar g (464 psi g) | 16 bar g (232 psi g) | 32 bar g (464 psi g) |
| 0.6 ... 63 bar g (9.14 ... 914 psi g) | 100 bar g (1450 psi g) | 63 bar g (914 psi g) | 100 bar g (1450 psi g) |
| 1.6 ... 160 bar g (23.2 ... 2320 psi g) | 250 bar g (3626 psi g) | 160 bar g (2320 psi g) | 250 bar g (3626 psi g) |
| 4.0 ... 400 bar g (58 ... 5802 psi g) | 600 bar g (8700 psi g) | 400 bar g (5802 psi g) | 600 bar g (8700 psi g) |
| 7.0 ... 700 bar g (102 ... 10153 psi g) | 800 bar g (11603 psi g) | 700 bar g (10153 psi g) | 800 bar g (11603 psi g) |
Lower measuring limit | | |
- Measuring cell with silicone oil filling
| 30 mbar a (0.435 psi a) |
- Measuring cell with inert filling liquid
| 30 mbar a (0.435 psi a) |
Upper measuring limit | 100 % of max. span (for oxygen version and inert filling liquid; max. 160 bar g (2320 psi g)) |
Output | | |
Output signal | 4 ... 20 mA | Digital PROFIBUS PA or Foundation Fieldbus signal |
- Lower limit (infinitely adjustable)
| 3.55 mA, factory preset to 3.84 mA | - |
- Upper limit (infinitely adjustable)
| 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA | - |
Load | |
- Without HART communication
| RB ? (UH - 10.5 V)/0.023 A in ?, UH : Power supply in V | - |
| RB = 230 ... 500 ? (SIMATIC PDM) or RB = 230 ... 1100 ? (HART Communicator) | - |
Physical bus | - | IEC 61158-2 |
Protection against polarity reversal | Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. |
Measuring accuracy | Acc. to EN 60770-1 |
Reference conditions (All error data refer always refer to the set span) | Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span) |
Error in measurement and fixed-point setting (including hysteresis and repeatability) | |
| | ? 0,075 % |
| ? (0.0029 · r + 0.071)% | |
| ? (0.0045 · r + 0.071)% | |
| ? (0.005 · r + 0.05)% | |
Long-term drift (temperature change ±30 °C (±54 °F)) | ? (0.25 · r)% every 5 years | ? 0.25 % every 5 years |
Influence of ambient temperature | |
- at -10 ... +60 °C (14 ... 140 °F)
| ? (0.08 · r + 0.1)% (at 700 bar: ? (0.1 · r + 0.2)% | ? 0,3 % |
- at -40 ... -10 °C and +60 ... +85 °C
(-40 ... +14 °F and 140 ... 185 °F)
| ? (0.1·r + 0.15) %/10 K | ? 0.25 %/10 K |
Measured Value Resolution | - | 3 · 10-5 of nominal measuring range |
Rated conditions | |
Degree of protection (to EN 60529) | IP65 |
Temperature of medium | |
- Measuring cell with silicone oil filling
| -40 ... +100 °C (-40 ... +212 °F) |
- Measuring cell with inert filling liquid
| -20 ... +100 °C (-4 ... +212 °F) |
- In conjunction with dust explosion protection
| -20 ... +60 °C (-4 ... +140 °F) |
Ambient conditions | |
| |
| -30 ... +85 °C (-22 ... +185 °F) |
| -50 ... +85 °C (-58 ... +185 °F) |
| |
| Permissible |
- Electromagnetic Compatibility
| |
| Acc. to EN 50081-1 |
| Acc. to EN 61326 and NAMUR NE 21 |
Design | |
Weight (without options) | ? 1.5 kg (? 3.3 lb) |
Enclosure material | Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, mat. No. 1.4408 |
Wetted parts materials | |
| Stainless steel, mat. No. 1.4404/316L or Hastelloy C4, mat. No. 2.4610 |
| Stainless steel, mat. No. 1.4404/316L |
| Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819 |
Measuring cell filling | Silicone oil or inert filling liquid (max. 160 bar (2320 psi g) with oxygen measurement) |
Process connection | Connection shank G?B to DIN EN 837-1, female thread ? -14 NPT or oval flange (PN 160 (MWP 2320 psi g)) to DIN 19213 with mounting thread M10 or 7/16-20 UNF to EN 61518 |
Material of mounting bracket | |
Steel | Sheet-steel, Mat. No. 1.0330, chrome-plated |
Stainless steel | Stainless steel, mat. No. 1.4301 (SS 304) |
Power supply UH | | Supplied through bus |
Terminal voltage on transmitter | 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode | - |
Separate 24 V power supply necessary | - | No |
Bus voltage | |
| - | 9 ...32 V |
- With intrinsically-safe operation
| - | 9 ...24 V |
Current consumption | |
| - | 12.5 mA |
- Startup current ? basic current
| - | Yes |
- Max. current in event of fault
| - | 15.5 mA |
Fault disconnection electronics (FDE) available | - | Yes |
Certificates and approvals | | |
Classification according to PED 97/23/EC | For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) |
Explosion protection | |
| PTB 99 ATEX 2122 |
| Ex II 1/2 G EEx ia/ib IIB/IIC T6 |
- Permissible ambient temperature
| -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 |
| To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 ? | FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W |
- Effective internal inductance/capacitance
| Li = 0.4 mH, Ci = 6 nF | Li = 7 ?H, Ci = 1.1 nF |
| PTB 99 ATEX 1160 |
| Ex II 1/2 G EEx d IIC T4/T6 |
- Permissible ambient temperature
| -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 |
| To circuits with values: UH = 10.5 ... 45 V DC | To circuits with values: UH = 9 ... 32 V DC |
- Dust explosion protection for zone 20
| PTB 01 ATEX 2055 |
| Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C |
- Permissible ambient temperature
| -40 ... +85 °C (-40 ... +185 °F) |
| 120 °C (248 °F) |
| To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 ? | FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W |
- Effective internal inductance/capacitance
| Li = 0.4 mH, Ci = 6 nF | Li = 7 ?H, Ci = 1.1 nF |
- Dust explosion protection for zone 21/22
| PTB 01 ATEX 2055 |
| Ex II 2 D IP65 T 120 °C |
| To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W | To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W |
- Type of protection "n" (zone 2)
| TUV 01 ATEX 1696 X | Planned |
| Ex II 3 G EEx nA L IIC T4/T5/T6 | - |
- Explosion protection acc. to FM
| Certificate of Compliance 3008490 |
- Identification (XP/DIP) or (IS); (NI)
| CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III |
- Explosion protection to CSA
| Certificate of Compliance 1153651 |
- Identification (XP/DIP) or (IS)
| CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III |