HART
|
PROFIBUS PA or Foundation Fieldbus
|
Input
|
|
Measured variable
|
Gauge pressure
|
Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure
|
Span
|
Max. perm. test pressure
|
Rated measuring range
|
Max. perm. test pressure
|
|
0,01 ... 1 bar g (0.15 ... 14.5 psi g)
|
6 bar g (87 psi g)
|
1 bar g (14.5 psi g)
|
6 bar g (87 psi g)
|
|
0.04 ... 4 bar g (0.58 ... 58 psi g)
|
10 bar g (145 psi g)
|
4 bar g (58 psi g)
|
10 bar g (145 psi g)
|
|
0.16 ... 16 bar g (2.32 ... 232 psi g)
|
32 bar g (464 psi g)
|
16 bar g (232 psi g)
|
32 bar g (464 psi g)
|
|
0.6 ... 63 bar g (9.14 ... 914 psi g)
|
100 bar g (1450 psi g)
|
63 bar g (914 psi g)
|
100 bar g (1450 psi g)
|
|
1.6 ... 160 bar g (23.2 ... 2320 psi g)
|
250 bar g (3626 psi g)
|
160 bar g (2320 psi g)
|
250 bar g (3626 psi g)
|
|
4.0 ... 400 bar g (58 ... 5802 psi g)
|
600 bar g (8700 psi g)
|
400 bar g (5802 psi g)
|
600 bar g (8700 psi g)
|
|
7.0 ... 700 bar g (102 ... 10153 psi g)
|
800 bar g (11603 psi g)
|
700 bar g (10153 psi g)
|
800 bar g (11603 psi g)
|
Lower measuring limit
|
|
|
- Measuring cell with silicone oil filling
|
30 mbar a (0.435 psi a)
|
- Measuring cell with inert filling liquid
|
30 mbar a (0.435 psi a)
|
Upper measuring limit
|
100 % of max. span (for oxygen version and inert filling liquid; max. 160 bar g (2320 psi g))
|
Output
|
|
|
Output signal
|
4 ... 20 mA
|
Digital PROFIBUS PA or Foundation Fieldbus signal
|
- Lower limit (infinitely adjustable)
|
3.55 mA, factory preset to 3.84 mA
|
-
|
- Upper limit (infinitely adjustable)
|
23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA
|
-
|
Load
|
|
- Without HART communication
|
R
B ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V
|
-
|
|
R
B = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator)
|
-
|
Physical bus
|
-
|
IEC 61158-2
|
Protection against polarity reversal
|
Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage.
|
Measuring accuracy
|
Acc. to EN 60770-1
|
Reference conditions (All error data refer always refer to the set span)
|
Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span)
|
Error in measurement and fixed-point setting (including hysteresis and repeatability)
|
|
|
|
≤ 0,075 %
|
|
≤ (0.0029 · r + 0.071)%
|
|
|
≤ (0.0045 · r + 0.071)%
|
|
|
≤ (0.005 · r + 0.05)%
|
|
Long-term drift (temperature change ±30 °C (±54 °F))
|
≤ (0.25 · r)% every 5 years
|
≤ 0.25 % every 5 years
|
Influence of ambient temperature
|
|
- at -10 ... +60 °C (14 ... 140 °F)
|
≤ (0.08 · r + 0.1)% (at 700 bar: ≤ (0.1 · r + 0.2)%
|
≤ 0,3 %
|
- at -40 ... -10 °C and +60 ... +85 °C
(-40 ... +14 °F and 140 ... 185 °F)
|
≤ (0.1·r + 0.15) %/10 K
|
≤ 0.25 %/10 K
|
Measured Value Resolution
|
-
|
3 · 10-5 of nominal measuring range
|
Rated conditions
|
|
Degree of protection (to EN 60529)
|
IP65
|
Temperature of medium
|
|
- Measuring cell with silicone oil filling
|
-40 ... +100 °C (-40 ... +212 °F)
|
- Measuring cell with inert filling liquid
|
-20 ... +100 °C (-4 ... +212 °F)
|
- In conjunction with dust explosion protection
|
-20 ... +60 °C (-4 ... +140 °F)
|
Ambient conditions
|
|
|
|
|
-30 ... +85 °C (-22 ... +185 °F)
|
|
-50 ... +85 °C (-58 ... +185 °F)
|
|
|
|
Permissible
|
- Electromagnetic Compatibility
|
|
|
Acc. to EN 50081-1
|
|
Acc. to EN 61326 and NAMUR NE 21
|
Design
|
|
Weight (without options)
|
≈ 1.5 kg (≈ 3.3 lb)
|
Enclosure material
|
Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, mat. No. 1.4408
|
Wetted parts materials
|
|
|
Stainless steel, mat. No. 1.4404/316L or Hastelloy C4, mat. No. 2.4610
|
|
Stainless steel, mat. No. 1.4404/316L
|
|
Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819
|
Measuring cell filling
|
Silicone oil or inert filling liquid (max. 160 bar (2320 psi g) with oxygen measurement)
|
Process connection
|
Connection shank G½B to DIN EN 837-1, female thread ½ -14 NPT or oval flange (PN 160 (MWP 2320 psi g)) to DIN 19213 with mounting thread M10 or 7/16-20 UNF to EN 61518
|
Material of mounting bracket
|
|
Steel
|
Sheet-steel, Mat. No. 1.0330, chrome-plated
|
Stainless steel
|
Stainless steel, mat. No. 1.4301 (SS 304)
|
Power supply
U
H
|
|
Supplied through bus
|
Terminal voltage on transmitter
|
10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode
|
-
|
Separate 24 V power supply necessary
|
-
|
No
|
Bus voltage
|
|
|
-
|
9 ...32 V
|
- With intrinsically-safe operation
|
-
|
9 ...24 V
|
Current consumption
|
|
|
-
|
12.5 mA
|
- Startup current ≤ basic current
|
-
|
Yes
|
- Max. current in event of fault
|
-
|
15.5 mA
|
Fault disconnection electronics (FDE) available
|
-
|
Yes
|
Certificates and approvals
|
|
|
Classification according to PED 97/23/EC
|
For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice)
|
Explosion protection
|
|
|
PTB 99 ATEX 2122
|
|
Ex II 1/2 G EEx ia/ib IIB/IIC T6
|
- Permissible ambient temperature
|
-40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6
|
|
To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω
|
FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W
Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W
|
- Effective internal inductance/capacitance
|
L
i = 0.4 mH, Ci = 6 nF
|
L
i = 7 μH, Ci = 1.1 nF
|
|
PTB 99 ATEX 1160
|
|
Ex II 1/2 G EEx d IIC T4/T6
|
- Permissible ambient temperature
|
-40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6
|
|
To circuits with values: UH = 10.5 ... 45 V DC
|
To circuits with values: UH = 9 ... 32 V DC
|
- Dust explosion protection for zone 20
|
PTB 01 ATEX 2055
|
|
Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C
|
- Permissible ambient temperature
|
-40 ... +85 °C (-40 ... +185 °F)
|
|
120 °C (248 °F)
|
|
To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω
|
FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W
Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W
|
- Effective internal inductance/capacitance
|
L
i = 0.4 mH, Ci = 6 nF
|
L
i = 7 μH, Ci = 1.1 nF
|
- Dust explosion protection for zone 21/22
|
PTB 01 ATEX 2055
|
|
Ex II 2 D IP65 T 120 °C
|
|
To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W
|
To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W
|
- Type of protection "n" (zone 2)
|
TÜV 01 ATEX 1696 X
|
Planned
|
|
Ex II 3 G EEx nA L IIC T4/T5/T6
|
-
|
- Explosion protection acc. to FM
|
Certificate of Compliance 3008490
|
- Identification (XP/DIP) or (IS); (NI)
|
CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III
|
- Explosion protection to CSA
|
Certificate of Compliance 1153651
|
- Identification (XP/DIP) or (IS)
|
CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III
|