Article?No.
|
6EP1?935-6MC01
|
6EP1?935-6MD31
|
6EP1?935-6MD11
|
6EP1?935-6ME21
|
6EP1?935-6MF01
|
Product
|
SITOP?Battery?module
|
SITOP?Battery?module
|
SITOP?Battery?module
|
SITOP?Battery?module
|
SITOP?Battery?module
|
Product?type
|
Battery?module?1.2?Ah
|
Battery?module?2.5?Ah
|
Battery?module?3.2?Ah
|
Battery?module?7?Ah
|
Battery?module?12?Ah
|
Charging?current?charging?voltage
|
|
|
|
|
|
End?of?charging?voltage?for?DC
|
|
|
|
|
|
|
|
29 V
|
|
|
|
|
|
28.6 V
|
|
|
|
|
27.8 V
|
28.3 V
|
27.8 V
|
27.8 V
|
27.8 V
|
|
27.3 V
|
27.9 V
|
27.3 V
|
27.3 V
|
27.3 V
|
|
26.8 V
|
27.5 V
|
26.8 V
|
26.8 V
|
26.8 V
|
|
26.6 V
|
27.2 V
|
26.6 V
|
26.6 V
|
26.6 V
|
|
26.3 V
|
26.8 V
|
26.3 V
|
26.3 V
|
26.3 V
|
|
|
26.4 V
|
|
|
|
Charging?current?maximum
|
0.3 A
|
5 A
|
0.8 A
|
1.75 A
|
3 A
|
Safety
|
|
|
|
|
|
Short-circuit?protection
|
Battery?fuse?7.5?A/32?V?(solid-state?circuitry?blade-type?fuse?+?support)
|
Battery?fuse?15?A/32?V?(solid-state?circuitry?blade-type?fuse?+?support)
|
Battery?fuse?15?A/32?V?(solid-state?circuitry?blade-type?fuse?+?support)
|
Battery?fuse?20?A/32?V?(solid-state?circuitry?blade-type?fuse?+?support)
|
Battery?fuse?20?A/32?V?(solid-state?circuitry?blade-type?fuse?+?support)
|
Design?of?the?overload?protection
|
Valve?control
|
Valve?control
|
Valve?control
|
Valve?control
|
Valve?control
|
Safety
|
|
|
|
|
|
Protection?class
|
Class?III
|
Class?III
|
Class?III
|
Class?III
|
Class?III
|
CE?mark
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
UL/cUL?(CSA)?approval
|
cURus-Recognized?(UL?1778,?CSA?C22.2?No.?107.1),?File?E219627
|
cURus-Recognized?(UL?1778,?CSA?C22.2?No.?107.1),?File?E219627
|
cURus-Recognized?(UL?1778,?CSA?C22.2?No.?107.1),?File?E219627
|
cURus-Recognized?(UL?1778,?CSA?C22.2?No.?107.1),?File?E219627
|
cURus-Recognized?(UL?1778,?CSA?C22.2?No.?107.1),?File?E219627
|
Degree?of?protection?(EN?60529)
|
IP00
|
IP00
|
IP00
|
IP00
|
IP00
|
Operating?data
|
|
|
|
|
|
|
For?storage,?mounting?and?operation?of?lead-acid?batteries,?the?relevant?DIN/VDE?regulations?or?country-specific?regulations?(e.g.?VDE?0510?Part?2/EN?50272-2)?must?be?observed.?You?must?ensure?that?the?battery?site?is?sufficiently?ventilated.?Possible?sources?of?ignition?must?be?at?least?50?cm?away.
|
For?storage,?mounting?and?operation?of?lead-acid?batteries,?the?relevant?DIN/VDE?regulations?or?country-specific?regulations?(e.g.?VDE?0510?Part?2/EN?50272-2)?must?be?observed.?You?must?ensure?that?the?battery?site?is?sufficiently?ventilated.?Possible?sources?of?ignition?must?be?at?least?50?cm?away.
|
For?storage,?mounting?and?operation?of?lead-acid?batteries,?the?relevant?DIN/VDE?regulations?or?country-specific?regulations?(e.g.?VDE?0510?Part?2/EN?50272-2)?must?be?observed.?You?must?ensure?that?the?battery?site?is?sufficiently?ventilated.?Possible?sources?of?ignition?must?be?at?least?50?cm?away.
|
For?storage,?mounting?and?operation?of?lead-acid?batteries,?the?relevant?DIN/VDE?regulations?or?country-specific?regulations?(e.g.?VDE?0510?Part?2/EN?50272-2)?must?be?observed.?You?must?ensure?that?the?battery?site?is?sufficiently?ventilated.?Possible?sources?of?ignition?must?be?at?least?50?cm?away.
|
For?storage,?mounting?and?operation?of?lead-acid?batteries,?the?relevant?DIN/VDE?regulations?or?country-specific?regulations?(e.g.?VDE?0510?Part?2/EN?50272-2)?must?be?observed.?You?must?ensure?that?the?battery?site?is?sufficiently?ventilated.?Possible?sources?of?ignition?must?be?at?least?50?cm?away.
|
Ambient?temperature
|
|
|
|
|
|
|
-15 … +50 °C
|
-40 … +60 °C
|
-15 … +50 °C
|
-15 … +50 °C
|
-15 … +50 °C
|
|
-20 … +50 °C
|
-40 … +60 °C
|
-20 … +50 °C
|
-20 … +50 °C
|
-20 … +50 °C
|
|
-20 … +50 °C
|
-40 … +60 °C
|
-20 … +50 °C
|
-20 … +50 °C
|
-20 … +50 °C
|
Relative,?temporary?capacity?loss?at?20?°C?in?a?month?typical
|
3 %
|
3 %
|
3 %
|
3 %
|
3 %
|
Service?life
|
|
|
|
|
|
Service?life?of?lead-acid?battery
|
|
|
|
|
|
|
capacity?falls?to?50?%?of?original?capacity
|
capacity?falls?to?50?%?of?original?capacity
|
capacity?falls?to?50?%?of?original?capacity
|
capacity?falls?to?50?%?of?original?capacity
|
capacity?falls?to?50?%?of?original?capacity
|
|
4 a
|
10 a
|
4 a
|
4 a
|
4 a
|
|
2 a
|
7 a
|
2 a
|
2 a
|
2 a
|
|
1 a
|
3 a
|
1 a
|
1 a
|
1 a
|
|
0.5 a
|
1.5 a
|
0.5 a
|
0.5 a
|
0.5 a
|
|
|
1 a
|
|
|
|
Ambient?temperature?during?storage?note
|
Along?with?the?storage?and?operating?temperature,?other?factors?such?as?the?duration?of?the?storage?period?and?the?charge?status?during?storage?have?a?decisive?influence?on?the?possible?useful?life.?Batteries?should?therefore?be?stored?as?briefly?as?possible,?always?fully?charged,?and?within?the?temperature?range?0?to?+20?°C.
|
Along?with?the?storage?and?operating?temperature,?other?factors?such?as?the?duration?of?the?storage?period?and?the?charge?status?during?storage?have?a?decisive?influence?on?the?possible?useful?life.?Batteries?should?therefore?be?stored?as?briefly?as?possible,?always?fully?charged,?and?within?the?temperature?range?0?to?+20?°C.
|
Along?with?the?storage?and?operating?temperature,?other?factors?such?as?the?duration?of?the?storage?period?and?the?charge?status?during?storage?have?a?decisive?influence?on?the?possible?useful?life.?Batteries?should?therefore?be?stored?as?briefly?as?possible,?always?fully?charged,?and?within?the?temperature?range?0?to?+20?°C.
|
Along?with?the?storage?and?operating?temperature,?other?factors?such?as?the?duration?of?the?storage?period?and?the?charge?status?during?storage?have?a?decisive?influence?on?the?possible?useful?life.?Batteries?should?therefore?be?stored?as?briefly?as?possible,?always?fully?charged,?and?within?the?temperature?range?0?to?+20?°C.
|
Along?with?the?storage?and?operating?temperature,?other?factors?such?as?the?duration?of?the?storage?period?and?the?charge?status?during?storage?have?a?decisive?influence?on?the?possible?useful?life.?Batteries?should?therefore?be?stored?as?briefly?as?possible,?always?fully?charged,?and?within?the?temperature?range?0?to?+20?°C.
|
Mechanics
|
|
|
|
|
|
Connection?technology
|
spring-loaded?terminals
|
spring-loaded?terminals
|
spring-loaded?terminals
|
spring-loaded?terminals
|
spring-loaded?terminals
|
Design?of?the?electrical?connection?for?power?supply?unit
|
1?screw?terminal?each?for?0.08?...?2.5?mm??for?+?BATT?and?-?BATT
|
1?screw?terminal?each?for?0.08?...?2.5?mm??for?+?BATT?and?-?BATT
|
1?screw?terminal?each?for?0.08?...?2.5?mm??for?+?BATT?and?-?BATT
|
1?screw?terminal?each?for?0.08?...?4?mm??for?+?BATT?and?-?BATT
|
1?screw?terminal?each?for?0.08?...?4?mm??for?+?BATT?and?-?BATT
|
Product?component?belonging?to
|
Accessories?pack?with?solid-state?circuitry?fuse?7.5?A
|
Accessories?pack?with?solid-state?circuitry?fuse?15?A
|
Accessories?pack?with?solid-state?circuitry?fuse?15?A
|
Accessories?pack?with?solid-state?circuitry?fuse?20?A?and?30?A
|
Accessories?pack?with?solid-state?circuitry?fuse?20?A?and?30?A
|
Width?of?the?housing
|
96 mm
|
265 mm
|
190 mm
|
186 mm
|
253 mm
|
Height?of?the?housing
|
106 mm
|
151 mm
|
151 mm
|
168 mm
|
168 mm
|
Depth?of?the?housing
|
108 mm
|
91 mm
|
82 mm
|
121 mm
|
121 mm
|
Installation?width
|
116 mm
|
285 mm
|
210 mm
|
206 mm
|
273 mm
|
Installation?height
|
126 mm
|
171 mm
|
171 mm
|
188 mm
|
188 mm
|
Weight,?approx.
|
1.8 kg
|
3.8 kg
|
3.2 kg
|
6 kg
|
9 kg
|
Installation
|
snaps?onto?DIN?rail?EN?60715?35x7.5/15?or?keyhole?mounting?for?hooking?in?to?M4?screws
|
snaps?onto?DIN?rail?EN?60715?35x15?or?keyhole?mounting?for?hooking?in?to?M4?screws
|
snaps?onto?DIN?rail?EN?60715?35x7.5/15?or?keyhole?mounting?for?hooking?in?to?M4?screws
|
can?be?screwed?onto?flat?surface?(keyhole?mounting?for?hooking?in?to?M4?screws)
|
can?be?screwed?onto?flat?surface?(keyhole?mounting?for?hooking?in?to?M4?screws)
|
Number?of?cells
|
12
|
12
|
12
|
12
|
12
|
Other?information
|
Specifications?at?rated?input?voltage?and?ambient?temperature?+25?°C?(unless?otherwise?specified)
|
Specifications?at?rated?input?voltage?and?ambient?temperature?+25?°C?(unless?otherwise?specified)
|
Specifications?at?rated?input?voltage?and?ambient?temperature?+25?°C?(unless?otherwise?specified)
|
Specifications?at?rated?input?voltage?and?ambient?temperature?+25?°C?(unless?otherwise?specified)
|
Specifications?at?rated?input?voltage?and?ambient?temperature?+25?°C?(unless?otherwise?specified)
|