Measuring principle
|
Radar level measurement
|
Frequency
|
K-band (25.0 GHz)
|
Minimum measuring range
|
50 mm (2 inch) from end of antenna
|
Maximum measuring range
|
20 m (66 ft)
|
Output
|
|
HART
|
Version 5.1
|
|
4 ... 20 mA
|
|
± 0.02 mA
|
|
- Programmable as high low or hold (loss of echo)
- NE 43 programmable
|
PROFIBUS PA
|
Profile 3.01
|
|
2 Analog Input (AI)
|
FOUNDATION Fieldbus
|
H1
|
|
Basic or LAS
|
|
ITK 5.2.0
|
|
2 Analog Input (AI)
|
Performance (according to reference conditions IEC60770-1)
|
|
Maximum measured error
|
- > 500 mm from sensor reference point: 3 mm (0.118 inch)
- < 500 mm from sensor reference point: 25 mm (1 inch)
|
Influence of ambient temperature
|
< 0.003 %/K
|
Rated operating conditions
|
|
Installation conditions
|
|
Location
|
Indoor/outdoor
|
Ambient conditions (enclosure)
|
|
Ambient temperature
|
-40 ... +80 °C (-40 ... +176 °F)
|
Installation category
|
I
|
Pollution degree
|
4
|
Medium conditions
|
|
Dielectric constant ?r
|
? 1.6 (antenna dependent)
|
Process temperature
|
-40 ... +170 °C (-40 ... +338 °F) at process connection
|
Process pressure
|
See Pressure/Temperature curves for more information
|
Design
|
|
Enclosure
|
|
|
Aluminum, polyester powder coated
|
|
2 x M20x1.5 or 2 x ?" NPT
|
Degree of protection
|
Type 4X/NEMA 4X, Type 6/NEMA 6, IP67, IP68
|
Weight (dependent on process connection)
|
- Approx. 4.7 kg (10.4 lb) for 2" ISO 2852 (smallest size)
- Approx. 7.9 kg (17.4 lb) for DN 100 DIN 11864-2 (largest size)
|
Display (local)
|
Graphic local user interface including quick start wizard and echo profile display
|
Antenna
|
|
|
Stainless steel 316L (1.4435 or 1.4404) and TFM 1600 PTFE Lens (lens is the only wetted part)
|
|
0.8 ?m
|
Process connections
|
|
Hygienic/Sanitary connections
|
- 2", 3" & 4" Sanitary Clamp according to ISO 2852
- DN 50, DN 80 & DN 100 Aseptic/Hygienic threaded to DIN 11864-1 [Form A]
- DN 50, DN 80 & DN 100 Aseptic/Hygienic flanged to DIN 11864-2 [Form A]
- DN 50, DN 80 & DN 100 Aseptic/Hygienic Clamp according to DIN 11864-3 [Form A]
- DN 50, DN 80 & DN 100 Hygienic Union according to DIN 11851
- Type F (50 mm) & Type N (68 mm) Tuchenhagen Varivent
|
Power supply
|
|
4 ... 20 mA/HART
|
Nominal 24 V DC (max. 30 V DC) with max. 550 ?
|
PROFIBUS PA
|
|
FOUNDATION Fieldbus
|
|
Certificates and approvals
|
|
General
|
CSAUS/C, CE, FM, NE 21, RCM
|
Radio
|
FCC, Industry Canada and Europe ETSI EN 302-372, RCM
|
Hazardous
|
|
|
INMETRO Ex d ia mb IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da
|
- Increased Safety (Brazil)
|
INMETRO Ex e ia mb IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da
|
- Intrinsically Safe (Brazil)
|
INMETRO Ex ia IIC T4 Ga, Ex ia ta IIIC T100 °C Da
|
- Explosion Proof (Canada/USA)
|
CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T4
|
- Intrinsically Safe (Canada/USA)
|
CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T4
|
- Non-incendive (Canada/USA)
|
CSA/FM Class I, Div. 2, Groups A, B, C, D T5
|
- Flame Proof/Increased Safety (China)
|
NEPSI Ex d ia mb IIC T4 Ga/Gb, Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP A20 TA90 ?C
|
- Intrinsically Safe (China)
|
NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA90 ?C
|
|
NEPSI Ex nA IIC T4 Gc
|
- Intrinsically Safe (Europe)
|
ATEX II 1G Ex ia IIC T4 Ga ATEX II 1D Ex ia ta IIIC T100 °C Da
|
|
ATEX II 3G Ex nA IIC T4 Gc
|
- Flame Proof (International/Europe)
|
IECEx/ATEX II 1/2 GD, 1D, 2D Ex d mb ia IIC T4 Ga/Gb, Ex ia ta IIC T100 °C Da
|
- Increased Safety (International/Europe)
|
IECEx/ATEX II 1/2 GD, 1D, 2D, Ex e mb ia IIC T4 Ga/Gb, Ex ia ta IIIC T100 °C Da
|
- Intrinsically Safe (International)
|
IECEx/ATEX II 1 G Ex ia IIC T4 Ga, IECEX/ATEX II 1D Ex ia ta IIIC T100 °C Da
|
|
GOST-R Ex d
|
- Increased Safety (Russia)
|
GOST-R Ex e
|
- Intrinsically Safe (Russia)
|
GOST-R Ex ia
|
Hygienic/Sanitary
|
EHEDG EL Class I
EHEDG EL Aseptic Class I
|
Programming
|
|
Intrinsically Safe Siemens handheld programmer
|
Infrared receiver
|
- Approvals for handheld programmer
|
IS model:
ATEX II 1 GD Ex ia IIC T4 Ga
Ex ia D 20 T135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1.,
Groups A, B, C, D, E, F, G, T6
Ta = 50 °C
IECEx SIR 09.0073
|
Handheld communicator
|
HART communicator 375/475
|
PC
|
- SIMATIC PDM
- Emerson AMS
- SITRANS DTM (for connection into FDT, such as PACTware or Fieldcare)
|
Display (local)
|
Graphic local user interface including quick start wizard and echo profile displays
|