Mode of operation
|
|
|
Measuring principle
|
Magnetic
|
|
Typical application
|
Monitoring loss of motion in tail pulley, screw flights, bucket elevators
|
|
Features
|
- Rugged corrosion resistant aluminum body
- Low voltage operation
- Large dynamic range
- Threaded body for finite adjustment
|
|
Output
|
NPN open collector
|
|
Performance
|
|
|
Repeatability
|
± 1 %
|
|
Dead band
|
± 0.25 %
|
|
Dynamic Range
|
0 ... 7 200 PPM
|
|
Ambient Temperature Range
|
-40 ... +60 °C (-40 ... +140 °F)
|
|
Design
|
|
|
Enclosure rating
|
Type 4X/NEMA 4X/IP67
|
|
Power Supply
|
21 ... 28 V DC, 40 mA max.
|
|
Certificates and approvals
|
CE, RCM
|
|
|