Options for special environments
In the chemical industry, a wide range of different environmental conditions occur. Through a series of options, the motors can be adapted to the conditions at the installation site.
|
Order code
|
Characteristics
|
|
K26
|
Outdoor use: Exposure to the weather admissible, minimal chemical pollution (SO2), direct solar radiation;
Special finish in RAL 7030 stone gray (corrosivity category C2)
|
|
E83
|
Outdoor use: Municipal and industrial atmospheres, moderate chemical pollution (SO2), minimal salinity, direct exposure to weather; special finish (corrosivity category C3)
|
|
E82
|
Outdoor use: Industrial areas and coastal areas with moderate salinity, direct exposure to weather, frequent condensation, special finish (corrosivity category C4)
|
|
E81
|
Outdoor use: Coastal and offshore areas with a high level of pollution and almost continuous condensation or industrial areas with high levels of humidity or corrosive atmospheres; special finish (corrosivity category C5?M/C5?I)
|
|
M06
|
Special case: Sulfurous atmosphere; special finish (corrosivity category C3)
|
Further options for the chemical industry
Additional options are listed below that are typically required for applications in the chemical industry.
|
Order code
|
Characteristics
|
|
M72
|
Design for Zone 2 for mains-fed operation Ex nA II T3 according to IEC/EN 60079?15
|
|
M73
|
Design for Zone 2 for converter-fed operation, with derating Ex nA II T3 according to IEC/EN 60079-15
|
|
M35
|
Design for Zone 22 for non-conductive dust (IP55) for mains-fed operation
|
|
M39
|
Design for Zone 22 for non-conductive dust (IP55) for converter-fed operation, derating
|
|
K56
|
IP56 degree of protection (non-heavy-sea)
|
|
K50
|
IP65 degree of protection
|
|
M27
|
Rust-resistant screws
|
|
K35
|
Metal external fan
|
|
|