Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2015
архивный
(4872) 700-366
skenergo@mail.ru

?

 

6ES7?315-7TJ10-0AB0

General?information

 

Hardware?product?version

01

Firmware?version

CPU:?V3.2;?integrated?technology?V4.1.5

Supply?voltage

 

24?V?DC

Yes

permissible?range,?lower?limit?(DC)

19.2 V

permissible?range,?upper?limit?(DC)

28.8 V

External?protection?for?supply?cables?(recommendation)

2?A?min.

Load?voltage?L+

 

  • Rated?value?(DC)

24 V

  • Reverse?polarity?protection

Yes

Digital?outputs

 

  • Load?voltage?L+

 

    • Rated?value?(DC)

24 V;?(2L+)

    • Reverse?polarity?protection

No;?(2L+)

Input?current

 

Current?consumption?(rated?value)

1 050 mA

Current?consumption?(in?no-load?operation),?typ.

230 mA

Inrush?current,?typ.

6.5 A

I?t

1 A?·s

Power?losses

 

Power?loss,?typ.

7.5 W

Memory

 

Type?of?memory

other

Work?memory

 

  • Integrated

384 kbyte

  • expandable

No

  • Size?of?retentive?memory?for?retentive?data?blocks

128 kbyte

Load?memory

 

  • pluggable?(MMC)

Yes

  • pluggable?(MMC),?max.

8 Mbyte

  • Data?management?on?MMC?(after?last?programming),?min.

10 a

Backup

 

  • present

Yes;?Guaranteed?by?MMC?(maintenance-free)

  • without?battery

Yes;?Program?and?data

CPU?processing?times

 

for?bit?operations,?typ.

0.05 µs

for?word?operations,?typ.

0.09 µs

for?fixed?point?arithmetic,?typ.

0.12 µs

for?floating?point?arithmetic,?typ.

0.45 µs

CPU-blocks

 

Number?of?blocks?(total)

1 024;?(DBs,?FCs,?FBs);?the?maximum?number?of?loadable?blocks?can?be?reduced?by?the?MMC?used.

DB

 

  • Number,?max.

1 024;?Number?range:?1?to?16000

  • Size,?max.

64 kbyte

FB

 

  • Number,?max.

1 024;?Number?range:?0?to?7999

  • Size,?max.

64 kbyte

FC

 

  • Number,?max.

1 024;?Number?range:?0?to?7999

  • Size,?max.

64 kbyte

OB

 

  • Description

see?instruction?list

  • Size,?max.

64 kbyte

  • Number?of?free?cycle?OBs

1;?OB?1

  • Number?of?time?alarm?OBs

1;?OB?10

  • Number?of?delay?alarm?OBs

2;?OB?20,?21

  • Number?of?time?interrupt?OBs

4;?OB?32,?33,?34,?35

  • Number?of?process?alarm?OBs

1;?OB?40

  • Number?of?DPV1?alarm?OBs

3;?OB?55,?56,?57

  • Number?isochronous?mode?OBs

1;?OB?61?-?isochronous?mode?is?possible?either?on?DP?or?PROFINET?IO?(not?simultaneously)

  • Number?of?technology?synchronous?alarm?OBs

1;?OB?65

  • Number?of?startup?OBs

1;?OB?100

  • Number?of?asynchronous?error?OBs

6;?OB?80,?82,?83,?85,?86,?87?(OB83?only?for?PROFINET?IO)

  • Number?of?synchronous?error?OBs

2;?OB?121,?122

Nesting?depth

 

  • per?priority?class

16

  • additional?within?an?error?OB

4

Counters,?timers?and?their?retentivity

 

S7?counter

 

  • Number

256

  • Retentivity

 

    • can?be?set

Yes

    • lower?limit

0

    • upper?limit

255

    • preset

Z?0?to?Z?7

  • Counting?range

 

    • can?be?set

Yes

    • lower?limit

0

    • upper?limit

999

IEC?counter

 

  • present

Yes

  • Type

SFB

  • Number

Unlimited?(limited?only?by?RAM?capacity)

S7?times

 

  • Number

256

  • Retentivity

 

    • can?be?set

Yes

    • lower?limit

0

    • upper?limit

255

    • preset

No?retentivity

  • Time?range

 

    • lower?limit

10 ms

    • upper?limit

9 990 s

IEC?timer

 

  • present

Yes

  • Type

SFB

  • Number

Unlimited?(limited?only?by?RAM?capacity)

Data?areas?and?their?retentivity

 

retentive?data?area,?total

All,?128?KB?max.

Flag

 

  • Number,?max.

2 048 byte

  • Retentivity?available

Yes;?MB?0?to?MB?2047

  • Retentivity?preset

MB?0?to?MB?15

  • Number?of?clock?memories

8;?1?memory?byte

Data?blocks

 

  • Number,?max.

1 024;?Number?range:?1?to?16000

  • Size,?max.

64 kbyte

  • Retentivity?adjustable

Yes;?via?non-retain?property?on?DB

  • Retentivity?preset

Yes

Local?data

 

  • per?priority?class,?max.

32 768 byte;?Max.?2048?bytes?per?block

Address?area

 

I/O?address?area

 

  • Inputs

2 048 byte

  • Outputs

2 048 byte

  • of?which,?distributed

 

    • Inputs

2 048 byte

    • Outputs

2 048 byte

Process?image

 

  • Inputs

2 048 byte

  • Outputs

2 048 byte

  • Inputs,?adjustable

2 048 byte

  • Outputs,?adjustable

2 048 byte

  • Inputs,?default

128 byte

  • Outputs,?default

128 byte

  • Default?addresses?of?the?integrated?channels

 

    • Digital?inputs

66

    • Digital?outputs

66

Subprocess?images

 

  • Number?of?subprocess?images,?max.

1;?With?PROFINET?IO,?the?length?of?the?user?data?is?limited?to?1600?bytes

Digital?channels

 

  • Inputs

16 384

  • Outputs

16 384

  • Inputs,?of?which?central

256

  • Outputs,?of?which?central

256

Analog?channels

 

  • Inputs

1 024

  • Outputs

1 024

  • Inputs,?of?which?central

64

  • Outputs,?of?which?central

64

Hardware?configuration

 

Expansion?devices,?max.

0

Number?of?DP?masters

 

  • Integrated

2;?1?DP?and?1?DP?(drive)

  • Via?CP

2;?for?DP

Number?of?operable?FMs?and?CPs?(recommended)

 

  • FM

8

  • CP,?point-to-point

8

  • CP,?LAN

8

Rack

 

  • Racks,?max.

1

  • Modules?per?rack,?max.

8

Time?of?day

 

Clock

 

  • Hardware?clock?(real-time?clock)

Yes

  • battery-backed?and?synchronizable

Yes

  • Deviation?per?day,?max.

10 s;?Typ.:?2?s

  • Backup?time

6 wk;?At?40?°C?ambient?temperature

  • Behavior?of?the?clock?following?POWER-ON

Clock?continues?running?after?POWER?OFF

  • Behavior?of?the?clock?following?expiry?of?backup?period

Clock?continues?to?run?with?the?time?at?which?the?power?failure?occurred

Operating?hours?counter

 

  • Number

1

  • Number/Number?range

0

  • Range?of?values

0?to?2^31?hours?(when?using?SFC?101)

  • Granularity

1?hour

  • retentive

Yes;?Must?be?restarted?at?each?restart

Clock?synchronization

 

  • supported

Yes

  • to?MPI,?master

Yes

  • to?MPI,?slave

Yes

  • to?DP,?master

Yes

  • to?DP,?slave

Yes;?Only?time-of-day?slave

  • in?AS,?master

Yes

  • in?AS,?slave

Yes

  • on?Ethernet?via?NTP

Yes;?As?client

Digital?inputs

 

Number?of?digital?inputs

4

  • of?which,?inputs?usable?for?technological?functions

4

Input?characteristic?curve?in?accordance?with?IEC?61131,?type?1

Yes

Number?of?simultaneously?controllable?inputs

 

  • horizontal?installation

 

    • up?to?40?°C,?max.

4

    • up?to?60?°C,?max.

4

  • vertical?installation

 

    • up?to?40?°C,?max.

4

Input?voltage

 

  • Rated?value?(DC)

24 V

  • for?signal?"0"

-3?to?+5V

  • for?signal?"1"

15?to?30?V

Input?current

 

  • for?signal?"1",?typ.

7 mA

Input?delay?(for?rated?value?of?input?voltage)

 

  • for?counter/technological?functions

 

    • at?"0"?to?"1",?max.

10 µs;?Typical

    • at?"1"?to?"0",?max.

10 µs;?Typical

Cable?length

 

  • Cable?length,?shielded,?max.

1 000 m

Digital?outputs

 

Number?of?digital?outputs

8

  • of?which?high-speed?outputs

8

Functions

For?technology?functions,?e.g.?high-speed?cam?switch?signals

short-circuit?protection

Yes

  • Response?threshold,?typ.

1,0?A

Limitation?of?inductive?shutdown?voltage?to

48?V

Controlling?a?digital?input

No

Switching?capacity?of?the?outputs

 

  • Lamp?load,?max.

5 W

Load?resistance?range

 

  • lower?limit

48 ?

  • upper?limit

4 k?

Output?voltage

 

  • for?signal?"0",?max.

3 V;?(2L+)

  • for?signal?"1",?min.

Rated?voltage?-2.5?V

Output?current

 

  • for?signal?"1"?rated?value

0.5 A

  • for?signal?"1"?permissible?range?for?0?to?60?°C,?min.

5 mA

  • for?signal?"1"?permissible?range?for?0?to?60?°C,?max.

0.6 A

  • for?signal?"0"?residual?current,?max.

0.3 mA

Parallel?switching?of?2?outputs

 

  • for?increased?power

No

  • for?redundant?control?of?a?load

No

Switching?frequency

 

  • with?resistive?load,?max.

100 Hz

  • with?inductive?load,?max.

0.2 Hz;?to?IEC?947-5-1,?DC-13

  • on?lamp?load,?max.

100 Hz

Aggregate?current?of?outputs?(per?group)

 

  • horizontal?installation

 

    • up?to?40?°C,?max.

4 A

    • up?to?60?°C,?max.

3 A

  • all?other?mounting?positions

 

    • up?to?40?°C,?max.

4 A

Integrated?high-speed?cams

 

  • Switching?accuracy,?(+/-)

70?µs

Cable?length

 

  • Cable?length,?shielded,?max.

1 000 m

Analog?inputs

 

Number?of?analog?inputs

0

Analog?outputs

 

Number?of?analog?outputs

0

Encoder

 

Connectable?encoders

 

  • 2-wire?sensor

No

Interfaces

 

Number?of?RS?422?interfaces

0

Number?of?other?interfaces

0

1st?interface

 

Interface?type

Integrated?RS?485?interface

Physics

RS?485

Isolated

Yes

Power?supply?to?interface?(15?to?30?V?DC),?max.

200 mA

Functionality

 

  • MPI

Yes

  • DP?master

Yes

  • DP?slave

Yes

  • Point-to-point?connection

No

MPI

 

  • Transmission?rate,?max.

12 Mbit/s

  • Services

 

    • PG/OP?communication

Yes

    • Routing

Yes

    • Global?data?communication

Yes

    • S7?basic?communication

Yes

    • S7?communication

Yes

    • S7?communication,?as?client

No;?but?via?CP?and?loadable?FB

    • S7?communication,?as?server

Yes

DP?master

 

  • Transmission?rate,?max.

12 Mbit/s

  • Number?of?DP?slaves,?max.

124

  • Services

 

    • PG/OP?communication

Yes

    • Routing

Yes

    • Global?data?communication

No

    • S7?basic?communication

Yes;?I?blocks?only

    • S7?communication

Yes

    • S7?communication,?as?client

No

    • S7?communication,?as?server

Yes

    • Equidistance?mode?support

Yes

    • Isochronous?mode

Yes;?OB?61;?isochronous?mode?can?only?be?used?alternatively?on?PROFIBUS?DP?or?PROFINET?IO

    • SYNC/FREEZE

Yes

    • Activation/deactivation?of?DP?slaves

Yes

    • Number?of?DP?slaves?that?can?be?simultaneously?activated/deactivated,?max.

8

    • Direct?data?exchange?(slave-to-slave?communication)

Yes;?As?subscriber

    • DPV1

Yes

  • Address?area

 

    • Inputs,?max.

2 kbyte

    • Outputs,?max.

2 kbyte

  • User?data?per?DP?slave

 

    • Inputs,?max.

244 byte

    • Outputs,?max.

244 byte

DP?slave

 

  • Transmission?rate,?max.

12 Mbit/s

  • Automatic?baud?rate?search

Yes;?only?with?passive?interface

  • Address?area,?max.

32

  • User?data?per?address?area,?max.

32 byte

  • Services

 

    • PG/OP?communication

Yes

    • Routing

Yes;?Only?with?active?interface

    • Global?data?communication

No

    • S7?basic?communication

No

    • S7?communication

Yes

    • S7?communication,?as?client

No

    • S7?communication,?as?server

Yes;?Connection?configured?on?one?side?only

    • Direct?data?exchange?(slave-to-slave?communication)

Yes

    • DPV1

No

  • Transfer?memory

 

    • Inputs

244 byte

    • Outputs

244 byte

2nd?interface

 

Interface?type

Integrated?RS?485?interface

Physics

RS?485

Isolated

Yes

Power?supply?to?interface?(15?to?30?V?DC),?max.

200 mA

Functionality

 

  • MPI

No

  • DP?master

Yes;?DP(DRIVE)-Master

  • DP?slave

No

  • Point-to-point?connection

No

DP?master

 

  • Transmission?rate,?max.

12 Mbit/s

  • Number?of?DP?slaves,?max.

64

  • Services

 

    • PG/OP?communication

No

    • Routing

No

    • Global?data?communication

No

    • S7?basic?communication

No

    • S7?communication

No

    • Equidistance?mode?support

Yes

    • Isochronous?mode

Yes

    • SYNC/FREEZE

No

    • Activation/deactivation?of?DP?slaves

Yes

    • DPV1

No

  • Address?area

 

    • Inputs,?max.

1 024 byte

    • Outputs,?max.

1 024 byte

  • User?data?per?DP?slave

 

    • Inputs,?max.

244 byte

    • Outputs,?max.

244 byte

DP?slave

 

  • GSD?file

http://support.automation.siemens.com?in?Product?Support?area

  • Transmission?rate,?max.

12 Mbit/s

3rd?interface

 

Interface?type

PROFINET

Physics

Ethernet?RJ45

Isolated

Yes

Integrated?switch

Yes

Number?of?ports

2

Automatic?detection?of?transmission?speed

Yes;?10/100?Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Change?of?IP?address?at?runtime,?supported

Yes

Media?redundancy

 

  • supported

Yes

  • Switchover?time?on?line?break,?typically

200 ms;?PROFINET?MRP

  • Number?of?stations?in?the?ring,?max.

50

Functionality

 

  • MPI

No

  • DP?master

No

  • DP?slave

No

  • PROFINET?IO?Controller

Yes;?Also?simultaneously?with?IO-Device?functionality

  • PROFINET?IO?Device

Yes;?Also?simultaneously?with?IO?Controller?functionality

  • Open?IE?communication

Yes;?Via?TCP/IP,?ISO?on?TCP,?and?UDP

  • Web?server

Yes

    • Number?of?HTTP?clients

5

PROFINET?IO?Controller

 

  • Transmission?rate,?max.

100 Mbit/s

  • Number?of?connectable?IO?devices,?max.

128

  • Max.?number?of?connectable?IO?devices?for?RT

128

    • of?which?in?line,?max.

128

  • Number?of?IO?Devices?with?IRT?and?the?option?"high?performance",?max.

64

    • of?which?in?line,?max.

64

  • Shared?device,?supported

Yes

  • Prioritized?startup?supported

Yes

    • Number?of?IO?Devices,?max.

32

  • Activation/deactivation?of?IO?Devices

Yes

    • Maximum?number?of?IO?devices?that?can?be?activated/deactivated?at?the?same?time.

8

  • IO?Devices?changing?during?operation?(partner?ports),?supported

Yes

    • Max.?number?of?IO?devices?per?tool

8

  • Device?replacement?without?swap?medium

Yes

  • Send?cycles

250?µs,?500?µs,?1?ms,?2?ms,?4?ms

  • Updating?time

250?µs?to?512?ms?(depending?on?the?operating?mode,?see?Manual?"S7-300?CPU?31xC?and?CPU?31x,?Technical?Data"?for?more?details)

  • Services

 

    • PG/OP?communication

Yes

    • Routing

Yes

    • S7?communication

Yes;?With?loadable?FBs,?max.?configurable?connections:?14,?max.?number?of?instances:?32

    • Isochronous?mode

Yes;?OB?61;?isochronous?mode?can?only?be?used?alternatively?on?PROFIBUS?DP?or?PROFINET?IO

    • Open?IE?communication

Yes;?Via?TCP/IP,?ISO?on?TCP,?and?UDP

  • Address?area

 

    • Inputs,?max.

2 kbyte

    • Outputs,?max.

2 kbyte

    • User?data?consistency,?max.

1 024 byte

PROFINET?IO?Device

 

  • Services

 

    • PG/OP?communication

Yes

    • Routing

Yes

    • S7?communication

Yes;?With?loadable?FBs,?max.?configurable?connections:?14,?max.?number?of?instances:?32

    • Isochronous?mode

No

    • Open?IE?communication

Yes;?Via?TCP/IP,?ISO?on?TCP,?and?UDP

    • IRT

Yes

    • PROFIenergy,?supported

Yes;?With?SFB?73?/?74?prepared?for?loadable?PROFIenergy?standard?FB?for?I-Device

    • Shared?device

Yes

    • Number?of?IO?controllers?with?shared?device,?max.

2

  • Transfer?memory

 

    • Inputs,?max.

1 440 byte;?Per?IO?Controller?with?shared?device

    • Outputs,?max.

1 440 byte;?Per?IO?Controller?with?shared?device

  • Submodules

 

    • Number,?max.

64

    • User?data?per?submodule,?max.

1 024 byte

Open?IE?communication

 

  • Open?IE?communication,?supported

Yes

  • Number?of?connections,?max.

8

  • Local?port?numbers?used?at?the?system?end

0,?20,?21,?23,?25,?80,?102,?135,?161,?443,?8080,?34962,?34963,?34964,?65532,?65533,?65534,?65535

  • Keep-alive?function,?supported

Yes

Isochronous?mode

 

Isochronous?operation?(application?synchronized?up?to?terminal)

Yes;?Via?PROFIBUS?DP?or?PROFINET?interface

Communication?functions

 

PG/OP?communication

Yes

Data?record?routing

Yes

Global?data?communication

 

  • supported

Yes

  • Number?of?GD?loops,?max.

8

  • Number?of?GD?packets,?max.

8

  • Number?of?GD?packets,?transmitter,?max.

8

  • Number?of?GD?packets,?receiver,?max.

8

  • Size?of?GD?packets,?max.

22 byte

  • Size?of?GD?packet?(of?which?consistent),?max.

22 byte

S7?basic?communication

 

  • supported

Yes

  • User?data?per?job,?max.

76 byte

  • User?data?per?job?(of?which?consistent),?max.

76 byte;?76?bytes?(with?X_SEND?or?X_RCV);?64?bytes?(with?X_PUT?or?X_GET?as?server)

S7?communication

 

  • supported

Yes

  • as?server

Yes

  • As?client

Yes;?via?integrated?PROFINET?interface?and?loadable?FB?or?via?CP?and?loadable?FB

  • User?data?per?job,?max.

See?online?help?of?STEP?7?(shared?parameters?of?the?SFBs/FBs?and?of?the?SFCs/FCs?of?S7?Communication)

S5-compatible?communication

 

  • supported

Yes;?via?CP?and?loadable?FC

Open?IE?communication

 

  • TCP/IP

Yes;?via?integrated?PROFINET?interface?and?loadable?FBs

    • Number?of?connections,?max.

8

    • Data?length?for?connection?type?01H,?max.

1 460 byte

    • Data?length?for?connection?type?11H,?max.

32 768 byte

    • Several?passive?connections?per?port,?supported

Yes

  • ISO-on-TCP?(RFC1006)

Yes;?via?integrated?PROFINET?interface?and?loadable?FBs

    • Number?of?connections,?max.

8

    • Data?length,?max.

32 768 byte

  • UDP

Yes;?via?integrated?PROFINET?interface?and?loadable?FBs

    • Number?of?connections,?max.

8

    • Data?length,?max.

1 472 byte

Web?server

 

  • supported

Yes

  • Number?of?HTTP?clients

5

  • User-defined?websites

Yes

Number?of?connections

 

  • overall

16

  • usable?for?PG?communication

15

    • reserved?for?PG?communication

1

    • Adjustable?for?PG?communication,?min.

1

    • Adjustable?for?PG?communication,?max.

15

  • usable?for?OP?communication

15

    • reserved?for?OP?communication

1

    • adjustable?for?OP?communication,?min.

1

    • adjustable?for?OP?communication,?max.

15

  • usable?for?S7?basic?communication

14

    • Reserved?for?S7?basic?communication

0

    • adjustable?for?S7?basic?communication,?min.

0

    • adjustable?for?S7?basic?communication,?max.

14

  • usable?for?S7?communication

14

    • reserved?for?S7?communication

0

    • Adjustable?for?S7?communication,?min.

0

    • Adjustable?for?S7?communication,?max.

14

  • Max.?total?number?of?instances

32

  • usable?for?routing

X1?as?MPI:?max.?10;?X1?as?DP?master:?max.?24;?X1?as?DP?slave?(active):?max.?14;?X2?as?PROFINET:?24?max.

S7?message?functions

 

Number?of?login?stations?for?message?functions,?max.

16;?Depending?on?the?configured?connections?for?PG/OP?and?S7?basic?communication

Process?diagnostic?messages

Yes

simultaneously?active?Alarm-S?blocks,?max.

300

Test?commissioning?functions

 

Status?block

Yes;?Up?to?2?simultaneously

Single?step

Yes

Number?of?breakpoints

4;?without?continuation

Status/control

 

  • Status/control?variable

Yes

  • Variables

Inputs,?outputs,?memory?bits,?DB,?times,?counters

  • Number?of?variables,?max.

30

  • of?which?status?variables,?max.

30

  • of?which?control?variables,?max.

14

Forcing

 

  • Forcing

Yes

  • Force,?variables

Inputs,?outputs

  • Number?of?variables,?max.

10

Diagnostic?buffer

 

  • present

Yes

  • Number?of?entries,?max.

500

    • can?be?set

No

    • Of?which?powerfail-proof

100;?Only?the?last?100?entries?are?retained

  • Number?of?entries?readable?in?RUN,?max.

499

    • can?be?set

Yes;?From?10?to?499

    • preset

10

Service?data

 

  • Can?be?read?out

Yes

Interrupts/diagnostics/status?information

 

Alarms

 

  • Alarms

No

Diagnostic?messages

 

  • Diagnostic?functions

No

Diagnostics?indication?LED

 

  • Status?indicator?digital?output?(green)

Yes

  • Status?indicator?digital?input?(green)

Yes

Galvanic?isolation

 

Galvanic?isolation?digital?inputs

 

  • between?the?channels?and?the?backplane?bus

Yes

Galvanic?isolation?digital?outputs

 

  • between?the?channels?and?the?backplane?bus

Yes

Permissible?potential?difference

 

between?different?circuits

75?VDC?/?60?VAC

Isolation

 

Isolation?checked?with

500?V?DC

Ambient?conditions

 

Operating?temperature

 

  • Min.

0 °C

  • max.

60 °C

Configuration

 

Configuration?software

 

  • STEP?7

Yes

programming

 

  • Command?set

see?instruction?list

  • Nesting?levels

8

  • System?functions?(SFC)

see?instruction?list

  • System?function?blocks?(SFB)

see?instruction?list

  • Programming?language

 

    • LAD

Yes

    • FBD

Yes

    • STL

Yes

    • SCL

Yes

    • CFC

Yes

    • GRAPH

Yes

    • HiGraph®

Yes

Know-how?protection

 

  • User?program?protection/password?protection

Yes

  • Block?encryption

Yes;?With?S7?block?Privacy

Dimensions

 

Width

120 mm

Height

125 mm

Depth

130 mm

Weights

 

Weight,?approx.

640 g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2015
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Промышленные системы автоматизации SIMATIC Программируемые контроллеры Логические модули LOGO! SIMATIC S7 S7-1200 S7-1500 S7-300/ S7-300F/ SIPLUS S7-300 Демонстрационные модели Центральные процессоры CPU стандартного исполнения CPU компактного исполнения F-CPU T-CPU CPU 315T-3 PN/DP CPU 317T-3 PN/DP CPU 317TF-3 PN/DP CPU 318-2 DP Сигнальные модули Функциональные модули Модули специального назначения Коммуникационные модули Соединительные устройства Блоки питания Интерфейсные модули IM 360/-361/-365 Интерфейсные модули SIPLUS IM 360/-361/-365 Аксессуары S7-400/S7-400H/S7-400F/FH Встраиваемые системы автоматизации SIMATIC PC-based Control Дополнительные компоненты Распределенный ввод/вывод Система автоматизации SIMATIC TDC Программное обеспечение для SIMATIC S7/WinAC Программаторы Наборы Micro Automation Sets SIEMENS Solution Partner Motion Control - система SIMOTION Системы автоматизации ЧПУ SINUMERIK Система соединителей/ шкафы управления Программное обеспечение для систем автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика