A06
|
Brush length monitoring, limit value monitoring, isolated
|
A30
|
Anti-condensation heating for motor, up to max. 2 000 W, 230 V
|
A97
|
Air flow monitoring in the motor
|
B30
|
Interlocking option for infeed circuit breaker
|
B60
|
Display instrument, "speed"
|
B61
|
Display instrument, "armature voltage"
|
B62
|
Display instrument, "armature current"
|
B63
|
Display instrument, "line voltage excitation"
|
B64
|
Display instrument, "excitation current"
|
B65
|
Display instrument, "line voltage armature circuit"
|
B66
|
Display instrument, "line current"
|
B83
|
Overvoltage protection
|
C51
|
24 V coil voltage of the coupling relay at the binary inputs
|
D02
|
Customer documentation (circuit diagram, terminal diagram, layout diagram) in the DXF format
|
D04
|
Customer documentation, paper
|
D14
|
Preliminary customer documentation
|
D19
|
Circuit diagram prepared for motor overtemperature monitoring using a limit value transmitter
|
D20
|
Circuit diagram prepared for motor temperature monitoring
|
D21
|
Circuit diagram prepared for speed actual value sensing (pulse encoder)
|
D22
|
Circuit diagram prepared for speed actual value sensing (analog tachometer)
|
D58
|
Documentation language: English/French
|
D60
|
Documentation language: English/Spanish
|
D61
|
Documentation language: English/Russian
|
D80
|
Documentation language: English/Italian
|
F03
|
Equipment acceptance with customer present: visual acceptance
|
F97
|
Equipment acceptance with customer present: customer-specific acceptance
|
G00
|
Advanced CUD left
|
G10
|
Standard CUD right
|
G11
|
Advanced CUD right
|
G20
|
Communication Board CBE20 left
|
G21
|
Communication Board CBE20 right
|
G60
|
Customer terminal strip extension TM31
|
G62
|
Customer terminal strip extension TM15
|
K07
|
Without Advanced Operator Panel AOP30
|
K50
|
Sensor Module Cabinet-Mounted SMC30
|
K85
|
Field reversal
|
L00
|
Radio interference suppression filter
|
L04
|
Armature supply with extra-low voltage 10 to 50 V
|
L05
|
Electronics power supply, SINAMICS DC MASTER for connection to 24 V DC
|
L06
|
24 V DC power supply with SITOP
|
L07
|
24 V DC power supply from an external supply
|
L09
|
24 V DC power supply with SITOP UPS
|
L10
|
Without field power section
|
L11
|
Field power section 2Q
|
L21
|
Unit fan for single-phase connection
|
L22
|
Elimination of the three-phase commutating reactor
|
L50
|
Cabinet lighting and service outlet
|
L52
|
ARC detector (arcing detector)
|
L55
|
Cabinet anti-condensation heating
|
L57
|
EMERGENCY OFF Category 0 for uncontrolled stopping in accordance with EN 60204-1
|
L59
|
EMERGENCY STOP Category 1 for controlled stopping in accordance with EN 60204-1
|
L82
|
Fault current monitoring in the grounded line supplies (TN or TT systems)
|
L84
|
PTC thermistor evaluation unit for alarm or fault for two sensors
|
L85
|
85 A field power section
|
L86
|
Evaluation unit for the following temperature sensors: KTY84-130, PT100 2-wire and 3-wire, PT1000 2-wire and 3-wire, NTC
|
L87
|
Insulation monitoring in non-grounded line supplies (IT system) with insulating monitoring devices from the Bender company
|
L88
|
Insulation monitoring in non-grounded line supplies (IT system) with insulating monitoring devices from the AREVA company
|
L90
|
CCP (Converter Commutation Protector)
|
L91
|
Commissioning interface (PROFIBUS) cabinet door access
|
L99
|
Monitoring the temperature inside the drive cabinet
|
M06
|
Base 100 mm high, RAL 7022
|
M07
|
Cable-marshaling space 200 mm high, RAL 7035
|
M08
|
Coated PCBs (only involves modules of the SINAMICS DC MASTER DC Converter)
|
M10
|
Nickel-plated copper busbars
|
M21
|
Degree of protection IP21
|
M23
|
Degree of protection IP23
|
M43
|
Degree of protection IP43
|
M54
|
Degree or protection IP54 with filter elements
|
M58
|
Degree or protection IP54 with climate control unit
|
M59
|
Cabinet door closed, entry from the bottom through an opening in the floor
|
M60
|
Additional shock hazard protection
|
M66
|
Marine version
|
M90
|
Crane transport aid (mounted at the top)
|
M91
|
Packaging type: wooden crate
|
M92
|
Packaging type: crate
|
M93
|
Packaging type: crate, seaworthy packaging
|
M94
|
Packaging type: additional packaging data IPPC ISPM15 (according to country-specific regulations)
|
P11
|
Display instrument for line quantities with PROFIBUS interface, installed in the cabinet door
|
Q80 … Q85
|
Extension of liability for defects – refer to the Section, “Description of the options”
|
S01
|
Memory card left
|
S02
|
Memory card right
|
U09
|
Version according to UL Listing
|
V60
|
Control extension for a rated line frequency of 60 Hz
|
V70
|
Input isolating amplifier, input: 0 to 20 mA
|
V71
|
Input isolating amplifier, input: 4 to 20 mA
|
V72
|
Input isolating amplifier, input: 0 to +10 V
|
V73
|
Input isolating amplifier, input: –20 to +20 mA
|
V74
|
Input isolating amplifier, input: –10 to +10 V
|
W15
|
No output provided for a motor fan
|
W20 … W41
|
Setting range of the motor protection circuit breaker for the motor fan
|
W70 … W91
|
Feeder for a second motor fan
|
Y01
|
Matching transformer for the motor fan
|
Y02
|
Matching transformer for the field supply
|
Y03
|
3 AC auxiliary voltage not available
|
Y04
|
3 AC auxiliary voltage not the same as the standard voltage
|
Y09
|
Special cabinet paint finish
|
Y32
|
Labeling plate to identify the system, two lines, 40 ? 180 mm
|
Y51
|
Motor holding brake
|
Y52
|
Output isolating amplifier, output: 0 to 20 mA
|
Y53
|
Output isolating amplifier, output: 4 to 20 mA
|
Y54
|
Output isolating amplifier, output: 0 to 10 V
|
Y55
|
Output isolating amplifier, output: –20 to +20 mA
|
Y56
|
Output isolating amplifier, output: –10 to 10 V
|
Y60
|
Coupling relay for binary output
|
|
Customer-specific requirement
|