SIWAREX WP241
|
|
|
Integration in automation systems
|
|
|
S7-1200
|
Directly via SIMATIC bus
|
- Operator Panel (not from the SIMATIC Basic series)
- Automation systems from other manufacturers
(possible with limitations)
|
Via Ethernet (Modbus TCP/IP) or RS 485 (Modbus RTU)
|
|
Communication interfaces
|
- SIMATIC S7-1200 backplane bus
- RS 485 (Modbus RTU)
- Ethernet (Modbus TCP/IP & SIWATOOL)
|
|
Commissioning of the scale
|
PC configuration software SIWATOOL (Ethernet) or Operator Panel (Modbus / S7-1200)
|
|
Calibration approval
|
MID according to OIML R50 (available soon)
|
|
Internal resolution
|
± 4 million parts
|
|
Number of measurements/second (internal)
|
100
|
|
Updating time for material flow rate
|
100 ms
|
|
Filter for conveyor load
|
Low-pass filter (limit frequency 0.05 ... 50 Hz)
|
|
Filter for belt speed
|
Low-pass filter (limit frequency 0.05 ... 50 Hz)
|
|
Weighing functions
|
|
|
Readout data
|
- Weight
- Belt load
- Material flow rate
- Accumulated total
- Main total
- Free totals 1 … 4
- Belt speed
|
|
Limits (min/max)
|
- Belt load
- Material flow rate
- Belt speed
|
|
Zeroing function
|
On command or automatic set to zero
|
|
Load cells
|
Strain gauges in 4-wire or 6-wire system
|
|
Load cell excitation
|
|
|
Supply voltage (regulated via feedback)
|
4.85 V DC
|
|
Permissible load resistance
|
|
|
|
> 40 ?
|
|
|
< 4100 ?
|
|
With SIWAREX IS Ex interface
|
|
|
|
> 50 ?
|
|
|
< 4100 ?
|
|
Load cell characteristic
|
1 … 4 mV/V
|
|
Permissible mesaurement signal range
|
-21.3 ... +21.3 mV
|
|
Max. distance of load cells
|
500 m (229.66 ft)
|
|
Connection to load cells in Ex zone 1
|
Optionally via SIWAREX IS Ex interface
|
|
Ex approvals
|
- ATEX Zone 2
- UL
- FM available soon
|
|
Auxiliary power supply
|
|
|
Rated voltage
|
24 V DC
|
|
Max. power consumption
|
200 mA
|
|
Max. power consumption SIMATIC Bus
|
3 mA
|
|
IP degree of protection to DIN EN 60529; IEC 60529
|
IP20
|
|
Climatic requirements Tmin (IND) ... Tmax (IND) (operating temperature)
|
|
|
Vertical installation
|
-10 ... +55 °C (14 ... 131 °F)
|
|
Horizontal installation
|
-10 ... +40 °C (14 ... 104 °F)
|
|
EMC requirements according to
|
EN 45501
|
|
Dimensions
|
70 x 75 x 100 mm (2.76 x 2.95 x 3.94 inches)
|