Article?No.
|
6EP1?456-3BA00
|
Technical?specifications
|
|
Product
|
SITOP?PSU300M
|
Power?supply,?type
|
48?V/10?A
|
Input
|
|
Input
|
3-phase?AC
|
Rated?voltage?value?Vin?rated?min.
|
400 V
|
Supply?voltage
|
|
- 1?with?AC?minimum?rated?value
|
|
- 2?with?AC?minimum?rated?value
|
|
Rated?voltage?value?Vin?rated?max.
|
500 V
|
Supply?voltage
|
|
- 1?with?AC?maximum?rated?value
|
|
- 2?at?AC?maximum?nominal?value
|
|
|
|
|
|
|
|
|
|
Voltage?range
|
320 … 575 V
|
Input?voltage
|
|
|
|
|
|
|
|
Overvoltage?resistance
|
2.3???Vin?rated,?1.3?ms
|
Mains?buffering?at?Iout?rated,?min.
|
15 ms
|
Mains?buffering
|
at?Vin?=?400?V
|
Rated?line?frequency
|
|
|
50 Hz
|
|
60 Hz
|
Rated?line?range
|
47 … 63 Hz
|
Input?current
|
|
- at?nominal?level?of?the?input?voltage?120?V?nominal?value
|
|
- at?nominal?level?of?the?input?voltage?230?V?nominal?value
|
|
- at?nominal?level?of?the?input?voltage?400?V?nominal?value
|
1.2 A
|
- at?nominal?level?of?the?input?voltage?500?V?nominal?value
|
1 A
|
- at?DC?at?nominal?level?of?the?input?voltage?600?V?nominal?value
|
|
Switch-on?current?limiting?(+25?°C),?max.
|
18 A
|
I?t,?max.
|
0.8 A?·s
|
Built-in?incoming?fuse
|
none
|
Protection?in?the?mains?power?input?(IEC?898)
|
Required:?3-pole?connected?miniature?circuit?breaker?6?...?16?A?characteristic?C?or?circuit?breaker?3RV2011-1DA10?(setting?3?A)?or?3RV2711-1DD10?(UL?489)
|
Output
|
|
Output
|
Controlled,?isolated?DC?voltage
|
Rated?voltage?Vout?DC
|
48 V
|
Total?tolerance,?static?±
|
3 %
|
Static?mains?compensation,?approx.
|
0.1 %
|
Static?load?balancing,?approx.
|
0.2 %
|
Residual?ripple?peak-peak,?max.
|
100 mV
|
Residual?ripple?peak-peak,?typ.
|
|
Spikes?peak-peak,?max.?(bandwidth:?20?MHz)
|
200 mV
|
Spikes?peak-peak,?typ.?(bandwidth:?20?MHz)
|
|
Adjustment?range
|
42 … 56 V
|
Product?feature?output?voltage?adjustable
|
Yes
|
Output?voltage?setting
|
via?potentiometer
|
Note
|
max.?480?W
|
Status?display
|
Green?LED?for?48?V?OK
|
Signaling
|
Relay?contact?(NO?contact,?rating?60?V?DC/?0.3?A)?for?48?V?OK
|
On/off?behavior
|
No?overshoot?of?Vout?(soft?start)
|
Startup?delay,?max.
|
2.5 s
|
Note
|
|
Voltage?rise,?typ.
|
150 ms
|
Voltage?increase?time?of?the?output?voltage?maximum
|
500 ms
|
Rated?current?value?Iout?rated
|
10 A
|
Current?range
|
0 … 10 A
|
Note
|
+60?...?+70?°C:?Derating?3%/K
|
delivered?active?power?typ.
|
480 W
|
short-term?overload?current?at?short-circuit?during?run-up?typical
|
|
Duration?of?overloading?ability?for?excess?current?on?short-circuiting?during?the?start-up
|
|
Constant?overload?current?in?the?event?of?a?short?circuit?during?startup?/typical
|
11 A
|
short-term?overload?current?at?short-circuit?during?operation?typical
|
23 A
|
Duration?of?overloading?ability?for?excess?current?on?short-circuiting?during?the?operational?phase
|
25 ms
|
constant?overload?current?at?short-circuit?during?operation?typical
|
|
Parallel?switching?for?enhanced?performance
|
Yes
|
Note
|
switchable?characteristic
|
Numbers?of?parallel?switchable?units?for?enhanced?performance
|
2
|
Efficiency
|
|
Efficiency?at?Vout?rated,?Iout?rated,?approx.
|
93 %
|
Power?loss?at?Vout?rated,?Iout?rated,?approx.
|
36 W
|
Closed-loop?control
|
|
Dynamic?mains?compensation?(Vin?rated?±15?%),?max.
|
1 %
|
Dynamic?load?smoothing?(Iout:?50/100/50?%),?Uout?±?typ.
|
2 %
|
Load?step?setting?time?50?to?100%,?typ.
|
2 ms
|
Load?step?setting?time?100?to?50%,?typ.
|
2 ms
|
Setting?time?maximum
|
10 ms
|
Protection?and?monitoring
|
|
Output?overvoltage?protection
|
Yes,?according?to?EN?60950-1
|
Current?limitation,?typ.
|
11 A
|
Characteristic?feature?of?the?output?short-circuit?protected
|
Yes
|
Short-circuit?protection
|
Alternatively,?constant?current?characteristic?approx.?11?A?or?latching?shutdown
|
Enduring?short?circuit?current?Effective?level?typical
|
11 A
|
Note
|
overload?capability?150?%?Iout?rated?up?to?5?s/min
|
Overload/short-circuit?indicator
|
LED?yellow?for?"overload",?LED?red?for?"latching?shutdown"
|
Safety
|
|
Primary/secondary?isolation
|
Yes
|
Potential?separation
|
Safety?extra-low?output?voltage?Uout?acc.?to?EN?60950-1?and?EN?50178
|
Protection?class
|
Class?I
|
stray?current
|
|
|
3.5 mA
|
|
|
CE?mark
|
Yes
|
UL/CSA?approval
|
Yes
|
UL/cUL?(CSA)?approval
|
cULus-Listed?(UL?508,?CSA?C22.2?No.?107.1),?File?E197259
|
Explosion?protection
|
ATEX?(EX)?II?3G?Ex?nA?nC?IIC?T4;?cCSAus?(CSA?C22.2?No.?213,?ANSI/ISA-12.12.01)?Class?I,?Div.?2,?Group?ABCD,?T4
|
FM?approval
|
No
|
FM?approval
|
-
|
CB?approval
|
Yes
|
Marine?approval
|
GL,?ABS
|
Degree?of?protection?(EN?60529)
|
IP20
|
EMC
|
|
Emitted?interference
|
EN?55022?Class?B
|
Supply?harmonics?limitation
|
EN?61000-3-2
|
Noise?immunity
|
EN?61000-6-2
|
Operating?data
|
|
Ambient?temperature
|
|
|
-10 … +70 °C
|
|
with?natural?convection
|
Ambient?temperature
|
|
|
-40 … +85 °C
|
Ambient?temperature
|
|
|
-40 … +85 °C
|
Humidity?class?according?to?EN?60721
|
Climate?class?3K3,?no?condensation
|
Mechanics
|
|
Connection?technology
|
screw-type?terminals
|
Connections
|
|
|
L1,?L2,?L3,?PE:?1?screw?terminal?each?for?0.5?...?2.5?mm??single-core/finely?stranded
|
|
+,?-:?2?screw?terminals?each?for?0.2?...?4?mm?
|
|
13,?14?(alarm?signal):?1?screw?terminal?each?for?0.14?...?1.5?mm?
|
Width?of?the?housing
|
70 mm
|
Height?of?the?housing
|
125 mm
|
Depth?of?the?housing
|
125 mm
|
Installation?width
|
70 mm
|
Installation?height
|
225 mm
|
Weight,?approx.
|
1.2 kg
|
Product?feature?of?the?housing?housing?for?side-by-side?mounting
|
Yes
|
Mounting?type
|
|
|
No
|
|
Yes
|
|
No
|
Installation
|
Snaps?onto?DIN?rail?EN?60715?35x7.5/15
|
Electrical?accessories
|
|
Mechanical?accessories
|
Device?identification?label?20?mm???7?mm,?pastel-turpuoise?3RT1900-1SB20
|