Product name
|
TM54F Terminal Module
6SL3055-0AA00-3BA0
|
|
Current requirement
(X524 at 24 V DC) without DRIVE-CLiQ supply
|
0.2 A
|
- Conductor cross-section, max.
|
2.5 mm2
|
|
|
20 A
|
|
Current requirement ext. 24 V, max.
For supplying the digital outputs and 24 V sensor supply (X514 at 24 V DC)
|
4 A
|
- Conductor cross-section, max.
|
2.5 mm2
|
|
|
20 A
|
|
I/O
|
|
- Number of fail-safe digital inputs
|
10
|
- Number of fail-safe digital outputs
|
4
|
|
|
3, of which 2 can be temporarily shut down using an internal test routine for dynamizing fail-safe digital inputs, current carrying capacity 0.5 A each
|
|
|
Plug-in screw-type terminals
|
- Conductor cross-section, max.
|
1.5 mm2
|
|
Digital inputs
According to IEC 61131?2 Type 1, with isolation
|
|
|
|
-3 … +30 V
|
- Low level (an open digital input is interpreted as low)
|
-3 … +5 V
|
|
|
15 … 30 V
|
- Current consumption at 24 V DC, typ.
|
> 2 mA
|
- Delay time of digital inputs, approx.1)
|
|
|
|
30 ?s
|
|
|
60 ?s
|
|
|
Low level (for inputs that can be inverted: without inversion)
|
|
Digital outputs
|
Sustained short-circuit strength
|
|
|
24 V DC
|
- Load current per fail-safe digital output, max.2)
|
0.5 A
|
- Delay times (resistive load) 1)
|
|
|
|
300 µs
|
|
|
350 µs
|
|
|
Output switched off
|
|
Scanning cycle tSI
For fail-safe digital inputs or fail-safe digital outputs
|
4 ... 25 ms (adjustable)
|
|
PE connection
|
M4 screw
|
|
Dimensions
|
|
|
|
50 mm (1.97 in)
|
|
|
150 mm (5.91 in)
|
|
|
111 mm (4.37 in)
|
|
Weight, approx.
|
0.9 kg (2 lb)
|
|
Approvals, according to
|
cULus
|
|
Safety Integrated
|
Safety Integrity Level 2 (SIL2) according to IEC 61508, Performance Level d (PLd) acc. to ISO 13849-1, Control Category 3 acc. to ISO 13849-1
|