Article?No.

6XV1?873-2A

6XV1?873-2B

6XV1?873-2G

Product-type?designation

FO?Standard?Cable?GP

FO?FRNC?Cable?GP

FO?Ground?Cable

Product?description

Glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Acceptability?for?application

 

 

 

Version?of?the?assembled?FO?cable

 

 

 

Cable?designation

AT-W(ZN)YY?2x1?G?50/125

AT-W(ZN)HH?2G?50/125?UV

AT-WQ(ZN)Y(ZN)B2Y?2G?50/125

Cable?length

-

-

-

Optical?data

 

 

 

Damping?ratio?per?length

 

 

 

  • at?850?nm?maximum

2,7 dB/km

2,7 dB/km

2,7 dB/km

  • at?1300?nm?maximum

0,7 dB/km

0,7 dB/km

0,7 dB/km

  • at?1550?nm?maximum

-

-

-

Bandwidth?length?product

 

 

 

  • at?850?nm

600 GHz·m

600 GHz·m

600 GHz·m

  • at?1300?nm

1 200 GHz·m

1 200 GHz·m

1 200 GHz·m

Mechanical?data

 

 

 

Number?of?fibers?per?FOC?core

1

1

1

Number?of?FOC?cores?per?FOC?cable

2

2

2

Version?of?the?FO?conductor?fiber

Multi-mode?gradient?fiber?50/125?µm,?OM?2

Multi-mode?gradient?fiber?50/125?µm,?OM?2

Multi-mode?gradient?fiber?50/125?µm,?OM?2

Design?of?the?FOC?core

 

 

 

Design?of?the?fiber-optic?cable

Segmentable

Segmentable

Segmentable

Outer?diameter

 

 

 

  • of?optical?fibers

50 µm

50 µm

50 µm

  • of?the?optical?fiber?sheath

125 µm

125 µm

125 µm

  • of?the?FOC?core?sheath

2,9 mm

2,9 mm

2,9 mm

  • of?the?cable

-

9,2 mm

10,5 mm

Symmetrical?deviation

 

 

 

  • of?the?outer?diameter?of?the?FOC?core?sheath

0,1 mm

0,1 mm

0,1 mm

  • of?the?outer?diameter?of?the?line

-

0,3 mm

0,5 mm

Width?of?the?cable?steath

7,4 mm

-

-

Symmetrical?tolerance?of?width?of?cable?sheath

-

-

-

Thickness?of?the?cable?sheath

4,5 mm

-

-

Symmetrical?tolerance?of?thickness?of?cable?sheath

-

-

-

Material

 

 

 

  • of?the?fiber-optic?cable?core

 

 

 

  • of?the?optical?fiber?sheath

 

 

 

  • of?the?FOC?core?sheath

PVC

FRNC

PVC

  • of?the?fiber-optic?cable?sheath

PVC

FRNC

PE

  • of?the?strain?relief

 

 

 

Color

 

 

 

  • of?the?FOC?core?sheath

 

 

 

  • of?the?cable?sheath

green

green

Black

Bending?radius

 

 

 

  • with?single?bend?minimum?permissible

45 mm

90 mm

105 mm

  • with?multiple?bends?minimum?permissible

65 mm

135 mm

155 mm

  • with?continuous?bending

-

-

-

Number?of?bending?cycles

-

-

-

Number?of?torsion?cycles?in?the?case?of?torsion?by?±?360°?on?1?m?cable?length

-

-

-

Traction?stress?maximum

500 N

500 N

800 N

Short-term?shear?force?per?length

600 N/cm

500 N/cm

500 N/cm

Continuous?lateral?force?per?length

400 N/cm

-

300 N/cm

Weight?per?length

40 kg/km

85 kg/km

90 kg/km

Permitted?ambient?conditions

 

 

 

Ambient?temperature

 

 

 

  • during?operating

-25 … +80 °C

-40 … +85 °C

-40 … +85 °C

  • during?storage

-25 … +80 °C

-40 … +85 °C

-40 … +85 °C

  • during?transport

-25 … +80 °C

-40 … +85 °C

-40 … +85 °C

  • during?installation

-5 … +50 °C

-5 … +50 °C

-5 … +50 °C

Ambient?condition?for?(standard)?operation?mode

-

-

-

Protection?class?IP

-

-

-

Burning?behaviour

 

 

 

Chemical?resistance

 

 

 

  • to?mineral?oil

Conditional?resistance

 

resistant

  • to?grease

Conditional?resistance

Conditional?resistance

resistant

  • to?water

Conditional?resistance

Conditional?resistance

resistant

Radiological?resistance?to?UV?radiation

 

 

 

Product?properties,?functions,?components?general

 

 

 

Product?feature

 

 

 

  • halogen-free

No

Yes

No

  • silicon-free

Yes

Yes

Yes

Product?component?Rodent?protection

No

No

Yes

Cable?length?for?glass?FOC

 

 

 

  • for?100BaseFX?for?Industrial?Ethernet?maximum

5 000 m

5 000 m

5 000 m

  • for?1000BaseSX?for?Industrial?Ethernet?maximum

750 m

750 m

750 m

  • for?1000BaseLX?for?Industrial?Ethernet?maximum

2 000 m

2 000 m

2 000 m

  • for?PROFIBUS?maximum

3 000 m

3 000 m

3 000 m

Standards,?specifications,?approvals

 

 

 

Verification?of?suitability

 

 

-

  • RoHS?conformity

Yes

Yes

Yes

Marine?classification?association

 

 

 

  • Bureau?Veritas?(BV)

-

-

-

  • Germanische?Lloyd?(GL)

-

-

-

  • Lloyds?Register?of?Shipping?(LRS)

-

-

-


Article?No.

6XV1?873-2C

6XV1?873-2D

Product-type?designation

FO?Trailing?Cable

FO?Trailing?Cable?GP

Product?description

Glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Acceptability?for?application

 

 

Version?of?the?assembled?FO?cable

 

 

Cable?designation

AT-W(ZN)Y(ZN)11Y?2G?50/125

AT-W(ZN)Y(ZN)Y?2G?50/125

Cable?length

-

-

Optical?data

 

 

Damping?ratio?per?length

 

 

  • at?850?nm?maximum

2,7 dB/km

2,7 dB/km

  • at?1300?nm?maximum

0,7 dB/km

0,7 dB/km

  • at?1550?nm?maximum

-

-

Bandwidth?length?product

 

 

  • at?850?nm

600 GHz·m

600 GHz·m

  • at?1300?nm

1 200 GHz·m

1 200 GHz·m

Mechanical?data

 

 

Number?of?fibers?per?FOC?core

1

1

Number?of?FOC?cores?per?FOC?cable

2

2

Version?of?the?FO?conductor?fiber

Multi-mode?gradient?fiber?50/125?µm,?OM?2

Multi-mode?gradient?fiber?50/125?µm,?OM?2

Design?of?the?FOC?core

 

 

Design?of?the?fiber-optic?cable

Segmentable

Segmentable

Outer?diameter

 

 

  • of?optical?fibers

50 µm

50 µm

  • of?the?optical?fiber?sheath

125 µm

125 µm

  • of?the?FOC?core?sheath

2,9 mm

2,9 mm

  • of?the?cable

10,5 mm

10,5 mm

Symmetrical?deviation

 

 

  • of?the?outer?diameter?of?the?FOC?core?sheath

0,1 mm

0,1 mm

  • of?the?outer?diameter?of?the?line

0,5 mm

0,5 mm

Width?of?the?cable?steath

-

-

Symmetrical?tolerance?of?width?of?cable?sheath

-

-

Thickness?of?the?cable?sheath

-

-

Symmetrical?tolerance?of?thickness?of?cable?sheath

-

-

Material

 

 

  • of?the?fiber-optic?cable?core

 

 

  • of?the?optical?fiber?sheath

 

 

  • of?the?FOC?core?sheath

PVC

PVC

  • of?the?fiber-optic?cable?sheath

PUR

PVC

  • of?the?strain?relief

 

 

Color

 

 

  • of?the?FOC?core?sheath

 

 

  • of?the?cable?sheath

green

green

Bending?radius

 

 

  • with?single?bend?minimum?permissible

150 mm

150 mm

  • with?multiple?bends?minimum?permissible

200 mm

200 mm

  • with?continuous?bending

-

-

Number?of?bending?cycles

5 000 000

3 500 000

Number?of?torsion?cycles?in?the?case?of?torsion?by?±?360°?on?1?m?cable?length

-

-

Traction?stress?maximum

800 N

800 N

Short-term?shear?force?per?length

700 N/cm

700 N/cm

Continuous?lateral?force?per?length

400 N/cm

400 N/cm

Weight?per?length

90 kg/km

90 kg/km

Permitted?ambient?conditions

 

 

Ambient?temperature

 

 

  • during?operating

-40 … +80 °C

-25 … +80 °C

  • during?storage

-40 … +80 °C

-25 … +80 °C

  • during?transport

-40 … +80 °C

-25 … +80 °C

  • during?installation

-5 … +50 °C

-5 … +50 °C

Ambient?condition?for?(standard)?operation?mode

-

-

Protection?class?IP

-

-

Burning?behaviour

 

 

Chemical?resistance

 

 

  • to?mineral?oil

resistant

Conditional?resistance

  • to?grease

resistant

Conditional?resistance

  • to?water

Conditional?resistance

Conditional?resistance

Radiological?resistance?to?UV?radiation

 

 

Product?properties,?functions,?components?general

 

 

Product?feature

 

 

  • halogen-free

No

No

  • silicon-free

Yes

Yes

Product?component?Rodent?protection

No

No

Cable?length?for?glass?FOC

 

 

  • for?100BaseFX?for?Industrial?Ethernet?maximum

5 000 m

5 000 m

  • for?1000BaseSX?for?Industrial?Ethernet?maximum

750 m

750 m

  • for?1000BaseLX?for?Industrial?Ethernet?maximum

2 000 m

2 000 m

  • for?PROFIBUS?maximum

3 000 m

3 000 m

Standards,?specifications,?approvals

 

 

Verification?of?suitability

-

UL?approval:?OFN?(NEC?Article?770,?UL?1651)?/?CSA?approval:?OFN?90?°C,?FT1,?FT4?(CSA?standard?C22.2?No.?232-M1988)

  • RoHS?conformity

Yes

Yes

Marine?classification?association

 

 

  • Bureau?Veritas?(BV)

-

-

  • Germanische?Lloyd?(GL)

-

-

  • Lloyds?Register?of?Shipping?(LRS)

-

-


Article?No.

6XV1?820-5AH10

6XV1?820-7AH10

Product-type?designation

Fiber?optic?standard?cable

INDOOR?fiber?optic?indoor?cable

Product?description

Flexible?glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Acceptability?for?application

 

 

Version?of?the?assembled?FO?cable

 

 

Cable?designation

AT-V(ZN)YY?2X1?G?62.5/125

I-V(ZN)HH?2x1?G?62.5/125

Cable?length

-

-

Optical?data

 

 

Damping?ratio?per?length

 

 

  • at?850?nm?maximum

3,1 dB/km

3,1 dB/km

  • at?1300?nm?maximum

0,8 dB/km

0,8 dB/km

  • at?1550?nm?maximum

-

-

Bandwidth?length?product

 

 

  • at?850?nm

200 GHz·m

200 GHz·m

  • at?1300?nm

600 GHz·m

600 GHz·m

Mechanical?data

 

 

Number?of?fibers?per?FOC?core

1

1

Number?of?FOC?cores?per?FOC?cable

2

2

Version?of?the?FO?conductor?fiber

 

 

Design?of?the?FOC?core

 

 

Design?of?the?fiber-optic?cable

Segmentable?outer?conductor

Segmentable?inner?conductor

Outer?diameter

 

 

  • of?optical?fibers

62,5 µm

62,5 µm

  • of?the?optical?fiber?sheath

125 µm

125 µm

  • of?the?FOC?core?sheath

3,5 mm

2,9 mm

  • of?the?cable

-

-

Symmetrical?deviation

 

 

  • of?the?outer?diameter?of?the?FOC?core?sheath

-

0,1 mm

  • of?the?outer?diameter?of?the?line

-

-

Width?of?the?cable?steath

9,8 mm

6,8 mm

Symmetrical?tolerance?of?width?of?cable?sheath

-

-

Thickness?of?the?cable?sheath

6,3 mm

3,9 mm

Symmetrical?tolerance?of?thickness?of?cable?sheath

-

-

Material

 

 

  • of?the?fiber-optic?cable?core

 

 

  • of?the?optical?fiber?sheath

 

 

  • of?the?FOC?core?sheath

PVC

FRNC

  • of?the?fiber-optic?cable?sheath

PVC

FRNC

  • of?the?strain?relief

 

 

Color

 

 

  • of?the?FOC?core?sheath

 

 

  • of?the?cable?sheath

Black

orange

Bending?radius

 

 

  • with?single?bend?minimum?permissible

80 mm

30 mm

  • with?multiple?bends?minimum?permissible

80 mm

50 mm

  • with?continuous?bending

-

-

Number?of?bending?cycles

-

-

Number?of?torsion?cycles?in?the?case?of?torsion?by?±?360°?on?1?m?cable?length

-

-

Traction?stress?maximum

1 500 N

200 N

Short-term?shear?force?per?length

-

300 N/cm

Continuous?lateral?force?per?length

200 N/cm

100 N/cm

Weight?per?length

70 kg/km

30 kg/km

Permitted?ambient?conditions

 

 

Ambient?temperature

 

 

  • during?operating

-40 … +85 °C

-20 … +60 °C

  • during?storage

-40 … +85 °C

-25 … +70 °C

  • during?transport

-40 … +85 °C

-25 … +70 °C

  • during?installation

-5 … +50 °C

-5 … +50 °C

Ambient?condition?for?(standard)?operation?mode

-

-

Protection?class?IP

-

-

Burning?behaviour

 

 

Chemical?resistance

 

 

  • to?mineral?oil

not?resistant

 

  • to?grease

not?resistant

not?resistant

  • to?water

Conditional?resistance

Conditional?resistance

Radiological?resistance?to?UV?radiation

 

 

Product?properties,?functions,?components?general

 

 

Product?feature

 

 

  • halogen-free

No

Yes

  • silicon-free

Yes

Yes

Product?component?Rodent?protection

No

No

Cable?length?for?glass?FOC

 

 

  • for?100BaseFX?for?Industrial?Ethernet?maximum

4 000 m

4 000 m

  • for?1000BaseSX?for?Industrial?Ethernet?maximum

350 m

350 m

  • for?1000BaseLX?for?Industrial?Ethernet?maximum

550 m

550 m

  • for?PROFIBUS?maximum

3 000 m

3 000 m

Standards,?specifications,?approvals

 

 

Verification?of?suitability

-

-

  • RoHS?conformity

Yes

Yes

Marine?classification?association

 

 

  • Bureau?Veritas?(BV)

-

-

  • Germanische?Lloyd?(GL)

-

-

  • Lloyds?Register?of?Shipping?(LRS)

-

-


Article?No.

6XV1?820-6AH10

6XV1?830-0NH10

Product-type?designation

Flexible?fiber?optic?trailing?cable

SIENOPYR?marine?duplex?fiber-optic?cable

Product?description

Flexible?glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Glass?fiber-optic?cable?SIENOPYR?marine?cable,?sold?by?the?meter,?unassembled

Acceptability?for?application

 

 

Version?of?the?assembled?FO?cable

 

 

Cable?designation

AT-W11Y(ZN)11Y?2?G?62.5/125

MI-VHH?2G?62.5/125?3.1B200?+?0.8F600?+?2x1Cu?300V

Cable?length

-

-

Optical?data

 

 

Damping?ratio?per?length

 

 

  • at?850?nm?maximum

3,1 dB/km

3,1 dB/km

  • at?1300?nm?maximum

0,8 dB/km

0,8 dB/km

  • at?1550?nm?maximum

-

-

Bandwidth?length?product

 

 

  • at?850?nm

200 GHz·m

200 GHz·m

  • at?1300?nm

600 GHz·m

600 GHz·m

Mechanical?data

 

 

Number?of?fibers?per?FOC?core

1

1

Number?of?FOC?cores?per?FOC?cable

2

2

Version?of?the?FO?conductor?fiber

 

Multi-mode?gradient?fiber?62.5/125?µm,?OM?2

Design?of?the?FOC?core

 

 

Design?of?the?fiber-optic?cable

Segmentable?outer?conductor

Segmentable?outer?conductor

Outer?diameter

 

 

  • of?optical?fibers

62,5 µm

62,5 µm

  • of?the?optical?fiber?sheath

125 µm

125 µm

  • of?the?FOC?core?sheath

3,5 mm

2,9 mm

  • of?the?cable

12,9 mm

13,3 mm

Symmetrical?deviation

 

 

  • of?the?outer?diameter?of?the?FOC?core?sheath

-

-

  • of?the?outer?diameter?of?the?line

-

0,5 mm

Width?of?the?cable?steath

-

-

Symmetrical?tolerance?of?width?of?cable?sheath

-

-

Thickness?of?the?cable?sheath

-

-

Symmetrical?tolerance?of?thickness?of?cable?sheath

-

-

Material

 

 

  • of?the?fiber-optic?cable?core

 

 

  • of?the?optical?fiber?sheath

 

-

  • of?the?FOC?core?sheath

PUR

Polyolefine

  • of?the?fiber-optic?cable?sheath

PUR

SHF1?mixture

  • of?the?strain?relief

 

 

Color

 

 

  • of?the?FOC?core?sheath

 

-

  • of?the?cable?sheath

Black

Black

Bending?radius

 

 

  • with?single?bend?minimum?permissible

150 mm

133 mm

  • with?multiple?bends?minimum?permissible

150 mm

266 mm

  • with?continuous?bending

-

-

Number?of?bending?cycles

100 000

-

Number?of?torsion?cycles?in?the?case?of?torsion?by?±?360°?on?1?m?cable?length

-

-

Traction?stress?maximum

1 000 N

250 N

Short-term?shear?force?per?length

-

-

Continuous?lateral?force?per?length

-

-

Weight?per?length

130 kg/km

220 kg/km

Permitted?ambient?conditions

 

 

Ambient?temperature

 

 

  • during?operating

-30 … +60 °C

-40 … +80 °C

  • during?storage

-30 … +70 °C

-40 … +80 °C

  • during?transport

-30 … +70 °C

-40 … +80 °C

  • during?installation

-30 … +60 °C

-10 … +50 °C

Ambient?condition?for?(standard)?operation?mode

-

At?ambient?temperatures?below?-10?degrees?Celsius,?the?cable?must?not?be?subjected?to?any?movements?other?than?the?normal?vibration?levels?encountered?on?board?ship

Protection?class?IP

-

-

Burning?behaviour

 

 

Chemical?resistance

 

 

  • to?mineral?oil

resistant

-

  • to?grease

resistant

-

  • to?water

Conditional?resistance

Conditional?resistance

Radiological?resistance?to?UV?radiation

 

 

Product?properties,?functions,?components?general

 

 

Product?feature

 

 

  • halogen-free

Yes

Yes

  • silicon-free

Yes

Yes

Product?component?Rodent?protection

No

No

Cable?length?for?glass?FOC

 

 

  • for?100BaseFX?for?Industrial?Ethernet?maximum

4 000 m

4 000 m

  • for?1000BaseSX?for?Industrial?Ethernet?maximum

350 m

350 m

  • for?1000BaseLX?for?Industrial?Ethernet?maximum

550 m

550 m

  • for?PROFIBUS?maximum

3 000 m

3 000 m

Standards,?specifications,?approvals

 

 

Verification?of?suitability

-

-

  • RoHS?conformity

Yes

Yes

Marine?classification?association

 

 

  • Bureau?Veritas?(BV)

-

Yes

  • Germanische?Lloyd?(GL)

-

Yes

  • Lloyds?Register?of?Shipping?(LRS)

-

Yes


Article?No.

6XV1?873-2R

6XV1?843-2R

Product-type?designation

MM?FO?Robust?Cable?GP

SM?FO?robust?cable?GP

Product?description

Glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Glass?fiber-optic?cable,?sold?by?the?meter,?unassembled

Acceptability?for?application

 

 

Version?of?the?assembled?FO?cable

 

 

Cable?designation

AT-V(ZN)H(ZN)BH?2G50/125

AT-V(ZN)H(ZN)BH?4E9/125

Cable?length

-

-

Optical?data

 

 

Damping?ratio?per?length

 

 

  • at?850?nm?maximum

2.7 dB/km

-

  • at?1300?nm?maximum

1 dB/km

0,5 dB/km

  • at?1550?nm?maximum

-

0,5 dB/km

Bandwidth?length?product

 

 

  • at?850?nm

600 GHz·m

-

  • at?1300?nm

1 200 GHz·m

-

Mechanical?data

 

 

Number?of?fibers?per?FOC?core

1

1

Number?of?FOC?cores?per?FOC?cable

2

4

Version?of?the?FO?conductor?fiber

Multi-mode?gradient?fiber?50/125/245?µm,?OM2

Single?mode?fiber?4E9/125/900,?OS1?and?OS2

Design?of?the?FOC?core

 

 

Design?of?the?fiber-optic?cable

Segmentable

Segmentable

Outer?diameter

 

 

  • of?optical?fibers

50 µm

9 µm

  • of?the?optical?fiber?sheath

125 µm

125 µm

  • of?the?FOC?core?sheath

2,2 mm

2,2 mm

  • of?the?cable

7,5 mm

9 mm

Symmetrical?deviation

 

 

  • of?the?outer?diameter?of?the?FOC?core?sheath

-

-

  • of?the?outer?diameter?of?the?line

-

-

Width?of?the?cable?steath

-

-

Symmetrical?tolerance?of?width?of?cable?sheath

-

-

Thickness?of?the?cable?sheath

-

-

Symmetrical?tolerance?of?thickness?of?cable?sheath

-

-

Material

 

 

  • of?the?fiber-optic?cable?core

 

 

  • of?the?optical?fiber?sheath

 

 

  • of?the?FOC?core?sheath

PE?flame?retardant

PE?flame?retardant

  • of?the?fiber-optic?cable?sheath

PE?flame?retardant

PE?flame?retardant

  • of?the?strain?relief

 

 

Color

 

 

  • of?the?FOC?core?sheath

 

 

  • of?the?cable?sheath

Black

Black

Bending?radius

 

 

  • with?single?bend?minimum?permissible

25 mm

90 mm

  • with?multiple?bends?minimum?permissible

40 mm

135 mm

  • with?continuous?bending

-

-

Number?of?bending?cycles

-

-

Number?of?torsion?cycles?in?the?case?of?torsion?by?±?360°?on?1?m?cable?length

-

-

Traction?stress?maximum

1 000 N

1 000 N

Short-term?shear?force?per?length

600 N/cm

600 N/cm

Continuous?lateral?force?per?length

200 N/cm

200 N/cm

Weight?per?length

67 kg/km

87 kg/km

Permitted?ambient?conditions

 

 

Ambient?temperature

 

 

  • during?operating

-40 … +70 °C

-40 … +70 °C

  • during?storage

-40 … +70 °C

-40 … +70 °C

  • during?transport

-40 … +70 °C

-40 … +70 °C

  • during?installation

-20 … +60 °C

-20 … +60 °C

Ambient?condition?for?(standard)?operation?mode

-

-

Protection?class?IP

-

-

Burning?behaviour

 

 

Chemical?resistance

 

 

  • to?mineral?oil

Conditional?resistance

Conditional?resistance

  • to?grease

Conditional?resistance

Conditional?resistance

  • to?water

resistant

resistant

Radiological?resistance?to?UV?radiation

 

 

Product?properties,?functions,?components?general

 

 

Product?feature

 

 

  • halogen-free

Yes

Yes

  • silicon-free

Yes

Yes

Product?component?Rodent?protection

Yes

Yes

Cable?length?for?glass?FOC

 

 

  • for?100BaseFX?for?Industrial?Ethernet?maximum

5 000 m

26 000 m

  • for?1000BaseSX?for?Industrial?Ethernet?maximum

750 m

-

  • for?1000BaseLX?for?Industrial?Ethernet?maximum

2 000 m

5 000 m

  • for?PROFIBUS?maximum

3 000 m

15 000 m

Standards,?specifications,?approvals

 

 

Verification?of?suitability

-

-

  • RoHS?conformity

Yes

Yes

Marine?classification?association

 

 

  • Bureau?Veritas?(BV)

-

-

  • Germanische?Lloyd?(GL)

-

-

  • Lloyds?Register?of?Shipping?(LRS)

-

-


Article?No.

6GK1?901-0DA20-0AA0

Product-type?designation

BFOC?Connector?Set

Product?description

 

Acceptability?for?application

For?connection?of?fiber-optic?cables

Transmission?rate

 

Transfer?rate

 

  • 1?for?Industrial?Ethernet

10 Mbit/s

  • 2?for?Industrial?Ethernet

100 Mbit/s

  • 3?for?Industrial?Ethernet

1 000 Mbit/s

  • with?PROFIBUS

9,6 kbit/s … 12 Mbit/s

Interfaces

 

Number?of?optical?interfaces?for?optical?waveguide

1

Design?of?optical?connections?for?network?components?or?terminal?devices

BFOC?connector

Design?of?the?electrical?connection?FastConnect

No

Mechanical?data

 

Material?of?the?enclosure

Metal?and?plastic

Design,?dimensions?and?weight

 

Type?of?cable?outlet

180?degree?cable?outlet

Width

10 mm

Height

10 mm

Depth

10 mm

Net?weight

8 g

Permitted?ambient?conditions

 

Ambient?temperature

 

  • during?operating

- -

  • during?storage

- -

  • during?transport

- -

Relative?humidity?at?25?°C?without?condensation?during?operating?maximum

-

Protection?class?IP

IP20

Chemical?resistance?to?water

-

Product?properties,?functions,?components?general

 

Product?feature?silicon-free

Yes

Product?component?strain?relief

Yes

Standards,?specifications,?approvals

 

Verification?of?suitability?RoHS?conformity

Yes


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2015
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Введение Industrial Ethernet PROFINET PROFIBUS Введение Полевая шина и передача данных процессов Передача данных Обзор коммуникаций Примеры конфигураций Топологии Сетевые компоненты для PROFIBUS Обзор сетевых компонент Критерии выбора типа сети Примеры соединений Электрические сети (RS485) Электрические сети (PROFIBUS-PA) Электрические сети FOUNDATION Fieldbus Оптические сети с OLM Обзор FC FOC оптических кабелей Стеклянные волоконно-оптические кабели быстрого монтажа FC FO монтажный комплект Стеклянный волоконно-оптический кабель Пластиковые и PCF волоконно-оптический кабели Набор инструментов для монтажа PCF FOC Модули OLM Оптические модули связи SIPLUS OLM Оптические сети с ОВТ и встроенными интерфейсами Беспроводные соединения Системные интерфейсы Сетевые переходы Управление в промышленности Приборы коммутации и защиты для распределения энергии Обзор системы Система управления потреблением энергии Производственные датчики RFID системы - коммуникационные модули Инжиниринговые пакеты Технологические компоненты для PROFIBUS Решения партнеров AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Информационная безопасность в промышленности Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика