6ES7211-0AA23-0XB0
|
6ES7211-0BA23-0XB0
|
6ES7212-1AB23-0XB0
|
6ES7212-1BB23-0XB0
|
Supply voltages
|
|
|
|
|
Rated value
|
|
|
|
|
|
Yes
|
|
Yes
|
|
- permissible range, lower limit (DC)
|
20.4 V
|
|
20.4 V
|
|
- permissible range, upper limit (DC)
|
28.8 V
|
|
28.8 V
|
|
|
|
Yes
|
|
Yes
|
|
|
Yes
|
|
Yes
|
- permissible range, lower limit (AC)
|
|
85 V
|
|
85 V
|
- permissible range, upper limit (AC)
|
|
264 V
|
|
264 V
|
- permissible frequency range, lower limit
|
|
47 Hz
|
|
47 Hz
|
- permissible frequency range, upper limit
|
|
63 Hz
|
|
63 Hz
|
Voltages and currents
|
|
|
|
|
Load voltage L+
|
|
|
|
|
|
24 V
|
24 V
|
24 V
|
24 V
|
- permissible range, lower limit (DC)
|
20.4 V
|
5 V
|
20.4 V
|
5 V
|
- permissible range, upper limit (DC)
|
28.8 V
|
30 V
|
28.8 V
|
30 V
|
Load voltage L1
|
|
|
|
|
|
|
100 V; 100 to 230 V AC
|
|
100 V; 100 to 230 V AC
|
- permissible range, lower limit (AC)
|
|
5 V
|
|
5 V
|
- permissible range, upper limit (AC)
|
|
250 V
|
|
250 V
|
- permissible frequency range, lower limit
|
|
47 Hz
|
|
47 Hz
|
- permissible frequency range, upper limit
|
|
63 Hz
|
|
63 Hz
|
Current consumption
|
|
|
|
|
|
10 A; at 28.8 V
|
20 A; at 264 V
|
10 A; at 28.8 V
|
20 A; at 264 V
|
- from supply voltage L+, max.
|
450 mA; 80 to 450 mA
|
|
500 mA; 85 to 500 mA, output current for expansion modules (5 V DC) 340 mA
|
|
- from supply voltage L1, max.
|
|
120 mA; 15 to 60 mA (240 V), 30 to 120 mA (120 V); output current for expansion modules (5 V DC) 340 mA
|
|
140 mA; 20 to 70 mA (240 V), 40 to 140 mA (120 V); output current for expansion modules (5 V DC) 340 mA
|
back-up battery
|
|
|
|
|
|
50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module
|
50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module
|
50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module
|
50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module
|
Memory/backup
|
|
|
|
|
Memory
|
|
|
|
|
- Number of memory modules (optional)
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
- Data memory and program memory
|
|
|
|
|
|
2 KByte
|
2 KByte
|
2 KByte
|
2 KByte
|
|
4 KByte
|
4 KByte
|
4 KByte
|
4 KByte
|
Backup
|
|
|
|
|
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
CPU/processing times
|
|
|
|
|
- for bit instruction, max.
|
0.22 µs
|
0.22 µs
|
0.22 µs
|
0.22 µs
|
Timers/counters and their retentive characteristics
|
|
|
|
|
S7 counter
|
|
|
|
|
|
256
|
256
|
256
|
256
|
- of which retentive with battery
|
|
|
|
|
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
|
1
|
1
|
1
|
1
|
|
256
|
256
|
256
|
256
|
|
|
|
|
|
|
0
|
0
|
0
|
0
|
|
32,767
|
32,767
|
32,767
|
32,767
|
S7 times
|
|
|
|
|
|
256
|
256
|
256
|
256
|
- of which retentive with battery
|
|
|
|
|
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
|
64
|
64
|
64
|
64
|
|
|
|
|
|
|
1 ms
|
1 ms
|
1 ms
|
1 ms
|
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
Data areas and their retentive characteristics
|
|
|
|
|
Flags
|
|
|
|
|
|
32 Byte
|
32 Byte
|
32 Byte
|
32 Byte
|
|
Yes; M0.0 to M31.7
|
Yes; M0.0 to M31.7
|
Yes; M0.0 to M31.7
|
Yes; M0.0 to M31.7
|
- of which retentive with battery
|
0 to 255, via super capacitor or battery, adjustable
|
0 to 255, via super capacitor or battery, adjustable
|
0 to 255, via super capacitor or battery, adjustable
|
0 to 255, via super capacitor or battery, adjustable
|
- of which retentive without battery
|
0 to 112 in EEPROM, adjustable
|
0 to 112 in EEPROM, adjustable
|
0 to 112 in EEPROM, adjustable
|
0 to 112 in EEPROM, adjustable
|
Configuration
|
|
|
|
|
- Connectable programming devices/PCs
|
SIMATIC PG/PC, Standard PC
|
SIMATIC PG/PC, Standard PC
|
SIMATIC PG/PC, Standard PC
|
SIMATIC PG/PC, Standard PC
|
- Central units/expansion units, max.
|
|
|
2 expansion modules. Only expansion modules of the S7-22x series can be used. Because of the limited output current, the use of expansion modules may be subject to restrictions.
|
2 expansion modules. Only expansion modules of the S7-22x series can be used (because of the limited output current, the use of expansion modules may be subject to restrictions.)
|
I/O expansions
|
|
|
|
|
- Analog inputs/outputs, max.
|
|
|
10; max. 8 inputs and 2 outputs (EM) or max. 0 inputs and 4 outputs (EM)
|
10; max. 8 inputs and 2 outputs (EM) or max. 0 inputs and 4 outputs (EM)
|
- Digital inputs/outputs, max.
|
|
|
78; max. 40 inputs and 38 outputs (CPU+EM)
|
78; max. 40 inputs and 38 outputs (CPU+EM)
|
- AS interface inputs/outputs, max.
|
|
|
31; AS interface slaves (CP 243-2)
|
31; AS interface slaves (CP 243-2)
|
Connection system
|
|
|
|
|
|
No
|
No
|
No
|
No
|
1st interface
|
|
|
|
|
|
integrated RS 485 interface
|
integrated RS 485 interface
|
integrated RS 485 interface
|
integrated RS 485 interface
|
|
RS 485
|
RS 485
|
RS 485
|
RS 485
|
Functionality
|
|
|
|
|
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
MPI
|
|
|
|
|
|
187.5 kBit/s
|
187.5 kBit/s
|
187.5 kBit/s
|
187.5 kBit/s
|
|
19.2 kBit/s
|
19.2 kBit/s
|
19.2 kBit/s
|
19.2 kBit/s
|
CPU/ programming
|
|
|
|
|
Programming language
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
- User program protection/password protection
|
Yes; 3-stage password protection
|
Yes; 3-stage password protection
|
Yes; 3-stage password protection
|
Yes; 3-stage password protection
|
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
- Number of sub-programs, max.
|
64
|
64
|
64
|
64
|
Digital inputs
|
|
|
|
|
|
6; integrated
|
6; integrated
|
8
|
8
|
Length of cable
|
|
|
|
|
- Length of cable shielded, max
|
500 m; Standard input: 500m, fast counters: 50m
|
500 m; Standard input: 500m, fast counters: 50m
|
500 m; Standard input: 500m, fast counters: 50m
|
500 m; Standard input: 500m, fast counters: 50m
|
- Length of cable unshielded, max
|
300 m; not for high-speed signals
|
300 m; not for high-speed signals
|
300 m; not for high-speed signals
|
300 m; not for high-speed signals
|
|
Yes; optional, per group
|
Yes; optional, per group
|
Yes; optional, per group
|
Yes; optional, per group
|
Input voltage
|
|
|
|
|
|
24 V
|
24 V
|
24 V
|
24 V
|
|
0 to 5 V
|
0 to 5 V
|
0 to 5 V
|
0 to 5 V
|
|
min. 15 V
|
min. 15 V
|
min. 15 V
|
min. 15 V
|
Input current
|
|
|
|
|
|
2.5 mA
|
2.5 mA
|
2.5 mA
|
2.5 mA
|
Input delay (at rated value of the input voltage)
|
|
|
|
|
|
|
|
|
|
|
Yes; all
|
Yes; all
|
Yes; all
|
Yes; all
|
|
0.2 ms
|
0.2 ms
|
0.2 ms
|
0.2 ms
|
|
12.8 ms
|
12.8 ms
|
12.8 ms
|
12.8 ms
|
|
|
|
|
|
|
Yes; I0.0 to I0.3
|
Yes; I0.0 to I0.3
|
Yes; I0.0 to I0.3
|
Yes; I0.0 to I0.3
|
- for counters/technological functions
|
|
|
|
|
|
Yes; (E0.0 to E0.5) 30 kHz
|
Yes; (E0.0 to E0.5) 30 kHz
|
Yes; (E0.0 to E0.5) 30 kHz
|
Yes; (E0.0 to E0.5) 30 kHz
|
Digital outputs
|
|
|
|
|
- Number of digital outputs
|
4; Transistor
|
4; Relay
|
6; Transistor
|
6; Relay
|
- Length of cable shielded, max.
|
500 m
|
500 m
|
500 m
|
500 m
|
- Length of cable unshielded, max.
|
150 m
|
150 m
|
150 m
|
150 m
|
- Short-circuit protection of the output
|
No; provided externally
|
No; provided externally
|
No; provided externally
|
No; provided externally
|
- Limitation of voltage induced on circuit interruption to
|
1 W
|
|
1 W
|
|
Switching capacity of the outputs
|
|
|
|
|
|
0.75 A
|
2 A
|
0.75 A
|
2 A
|
|
5 W
|
30 W DC, 200 W AC
|
5 W
|
30 W DC, 200 W AC
|
Output voltage
|
|
|
|
|
|
20 V DC
|
L+/L1
|
20 V DC
|
L+/L1
|
Output current
|
|
|
|
|
|
750 mA
|
2 A
|
750 mA
|
2 A
|
- for 0 signal residual current, max.
|
0.1 mA
|
0 mA
|
10 ?A
|
0 mA
|
Output delay at resistive load
|
|
|
|
|
|
15 µs; of standard outputs, max. (A0.2 to A0.3) 15 µs; of pulse outputs, max. (A0.0 to A0.1) 2 µs
|
10 ms; all outputs
|
15 µs; of standard outputs, max. (A0.2 to A0.5) 15 µs; of pulse outputs, max. (A0.0 to A0.1) 2 µs
|
10 ms; all outputs
|
|
130 µs; of standard outputs, max. (A0.2 to A0.3) 100 µs; of pulse outputs, max. (A0.0 to A0.1) 10 µs
|
10 ms; all outputs
|
130 µs; of standard outputs, max. (A0.2 to A0.5) 100 µs; of pulse outputs, max. (A0.0 to A0.1) 10 µs
|
10 ms; all outputs
|
Parallel switching of 2 outputs
|
|
|
|
|
|
Yes
|
No
|
Yes
|
No
|
Switching frequency
|
|
|
|
|
- of pulse outputs, at resistive load, max.
|
20 kHz; A0.0 to A0.1
|
|
20 kHz; A0.0 to A0.1
|
|
Summation current of the outputs (per group)
|
|
|
|
|
|
3 A
|
6 A
|
4.5 A
|
6 A
|
- horizontal installation, up to 55 °C, max.
|
3 A
|
6 A
|
4.5 A
|
6 A
|
Relay outputs
|
|
|
|
|
- Number of operating cycles
|
|
10,000,000; mechanical 10 million, at rated load voltage 100,000
|
|
10,000,000; mechanical 10 million, at rated load voltage 100,000
|
Analog inputs
|
|
|
|
|
- Number of analog potentiometers
|
1; Analog potentiometer; resolution 8 bits
|
1; Analog potentiometer; resolution 8 bits
|
1; Analog potentiometer; resolution 8 bits
|
1; Analog potentiometer; resolution 8 bits
|
Sensor supply
|
|
|
|
|
24 V - sensor supply
|
|
|
|
|
|
Yes; permissible range: 15.4 to 28.8 V
|
Yes; permissible range: 20.4 to 28.8 V
|
Yes; permissible range: 15.4 to 28.8 V
|
Yes; permissible range: 20.4 to 28.8 V
|
|
Yes; electronic at 600 mA
|
Yes; electronic at 600 mA
|
Yes; electronic at 600 mA
|
Yes; electronic at 600 mA
|
|
180 mA
|
180 mA
|
180 mA
|
180 mA
|
Sensor
|
|
|
|
|
Connectable encoders
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
- permissible closed-circuit current (2-wire BEROS), max.
|
1 mA
|
1 mA
|
1 mA
|
1 mA
|
Integral functions
|
|
|
|
|
|
4; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
4; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
4; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
4; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
- Count frequency (counters) max.
|
30 kHz
|
30 kHz
|
30 kHz
|
30 kHz
|
|
4; 4 rising edges and/or 4 falling edges
|
4; 4 rising edges and/or 4 falling edges
|
4; 4 rising edges and/or 4 falling edges
|
4; 4 rising edges and/or 4 falling edges
|
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
- Cut-off frequency (pulse)
|
20 kHz
|
20 kHz
|
20 kHz
|
20 kHz
|
Potentials/ electrical isolation
|
|
|
|
|
Digital output functions
|
|
|
|
|
|
Yes; Optocoupler
|
Yes; Relay
|
Yes; Optocoupler
|
Yes; Relay
|
- between the channels, in groups of
|
4
|
1 and 3
|
6
|
3
|
Digital input functions
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
- between the channels, in groups of
|
2 and 4
|
2 and 4
|
4
|
4
|
Permissible potential difference
|
|
|
|
|
- between different circuits
|
500 V DC between 24 V DC and 5 V DC
|
500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC
|
500 V DC between 24 V DC and 5 V DC
|
500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC
|
Environmental requirements
|
|
|
|
|
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
Operating temperature
|
|
|
|
|
|
0 °C
|
0 °C
|
0 °C
|
0 °C
|
|
45 °C
|
45 °C
|
45 °C
|
45 °C
|
- horizontal mounting, min.
|
0 °C
|
0 °C
|
0 °C
|
0 °C
|
- horizontal mounting, max.
|
55 °C
|
55 °C
|
55 °C
|
55 °C
|
Air pressure
|
|
|
|
|
|
860 hPa
|
860 hPa
|
860 hPa
|
860 hPa
|
|
1,080 hPa
|
1,080 hPa
|
1,080 hPa
|
1,080 hPa
|
Relative humidity
|
|
|
|
|
|
5 %
|
5 %
|
5 %
|
5 %
|
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
Degree of protection and class of protection
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Dimensions and weight
|
|
|
|
|
|
270 g
|
310 g
|
270 g
|
310 g
|
|
90 mm
|
90 mm
|
90 mm
|
90 mm
|
|
80 mm
|
80 mm
|
80 mm
|
80 mm
|
|
62 mm
|
62 mm
|
62 mm
|
62 mm
|
|
6ES7214-1AD23-0XB0
|
6ES7214-1BD23-0XB0
|
6ES7214-2AD23-0XB0
|
6ES7214-2BD23-0XB0
|
6ES7216-2AD23-0XB0
|
6ES7216-2BD23-0XB0
|
Supply voltages
|
|
|
|
|
|
|
Rated value
|
|
|
|
|
|
|
|
Yes
|
|
Yes
|
|
Yes
|
|
- permissible range, lower limit (DC)
|
20.4 V
|
|
20.4 V
|
|
20.4 V
|
|
- permissible range, upper limit (DC)
|
28.8 V
|
|
28.8 V
|
|
28.8 V
|
|
|
|
Yes
|
|
Yes
|
|
Yes
|
|
|
Yes
|
|
Yes
|
|
Yes
|
- permissible range, lower limit (AC)
|
|
85 V
|
|
85 V
|
|
85 V
|
- permissible range, upper limit (AC)
|
|
264 V
|
|
264 V
|
|
264 V
|
- permissible frequency range, lower limit
|
|
47 Hz
|
|
47 Hz
|
|
47 Hz
|
- permissible frequency range, upper limit
|
|
63 Hz
|
|
63 Hz
|
|
63 Hz
|
Voltages and currents
|
|
|
|
|
|
|
Load voltage L+
|
|
|
|
|
|
|
|
24 V
|
24 V
|
24 V
|
24 V
|
24 V
|
24 V
|
- permissible range, lower limit (DC)
|
20.4 V
|
5 V
|
20.4 V
|
5 V
|
20.4 V
|
5 V
|
- permissible range, upper limit (DC)
|
28.8 V
|
30 V
|
28.8 V
|
30 V
|
28.8 V
|
30 V
|
Load voltage L1
|
|
|
|
|
|
|
|
|
100 V; 100 to 230 V AC
|
|
100 V; 100 to 230 V AC
|
|
100 V; 100 to 230 V AC
|
- permissible range, lower limit (AC)
|
|
5 V
|
|
5 V
|
|
5 V
|
- permissible range, upper limit (AC)
|
|
250 V
|
|
250 V
|
|
250 V
|
- permissible frequency range, lower limit
|
|
47 Hz
|
|
47 Hz
|
|
47 Hz
|
- permissible frequency range, upper limit
|
|
63 Hz
|
|
63 Hz
|
|
63 Hz
|
Current consumption
|
|
|
|
|
|
|
|
12 A; at 28.8 V
|
20 A; at 264 V
|
12 A; at 28.8 V
|
20 A; at 264 V
|
10 A; at 28.8 V
|
20 A; at 264 V
|
- from supply voltage L+, max.
|
700 mA; 110 to 700 mA, output current for expansion modules (5 V DC) 660 mA
|
|
900 mA; 120 to 900 mA, output current for expansion modules (5 V DC) 660 mA
|
|
1,050 mA; 150 to 1050 mA, output current for expansion modules (5 V DC) 1000 mA
|
|
- from supply voltage L1, max.
|
|
200 mA; 30 to 100 mA (240 V), 60 to 200 mA (120 V); output current for expansion modules (5 V DC) 600 mA
|
|
220 mA; 35 to 100 mA (240 V), 70 to 220 mA (120 V); output current for expansion modules (5 V DC) 600 mA
|
|
320 mA; 40 to 160 mA (240 V), 80 to 320 mA (120 V); output current for expansion modules (5 V DC) 1000 mA
|
back-up battery
|
|
|
|
|
|
|
|
100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module
|
100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module
|
100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module
|
100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module
|
100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module
|
100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module
|
Memory/backup
|
|
|
|
|
|
|
Memory
|
|
|
|
|
|
|
- Number of memory modules (optional)
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved.
|
- Data memory and program memory
|
|
|
|
|
|
|
|
8 KByte
|
8 KByte
|
10 KByte
|
10 KByte
|
10 KByte
|
10 KByte
|
|
12 KByte; 8 Kbytes for active run-time edit
|
12 KByte; 8 Kbytes for active run-time edit
|
16 KByte; 12 Kbytes for active run-time edit
|
16 KByte; 12 Kbytes for active run-time edit
|
24 KByte; 16 Kbytes with active run-time edit
|
24 KByte; 16 Kbytes with active run-time edit
|
Backup
|
|
|
|
|
|
|
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery
|
CPU/processing times
|
|
|
|
|
|
|
- for bit instruction, max.
|
0.22 µs
|
0.22 µs
|
0.22 µs
|
0.22 µs
|
0.22 µs
|
0.22 µs
|
Timers/counters and their retentive characteristics
|
|
|
|
|
|
|
S7 counter
|
|
|
|
|
|
|
|
256
|
256
|
256
|
256
|
256
|
256
|
- of which retentive with battery
|
|
|
|
|
|
|
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
|
1
|
1
|
1
|
1
|
1
|
1
|
|
256
|
256
|
256
|
256
|
256
|
256
|
|
|
|
|
|
|
|
|
0
|
0
|
0
|
0
|
0
|
0
|
|
32,767
|
32,767
|
32,767
|
32,767
|
32,767
|
32,767
|
S7 times
|
|
|
|
|
|
|
|
256
|
256
|
256
|
256
|
256
|
256
|
- of which retentive with battery
|
|
|
|
|
|
|
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
Yes; via super capacitor or battery
|
|
64
|
64
|
64
|
64
|
64
|
64
|
|
|
|
|
|
|
|
|
1 ms
|
1 ms
|
1 ms
|
1 ms
|
1 ms
|
1 ms
|
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min
|
Data areas and their retentive characteristics
|
|
|
|
|
|
|
Flags
|
|
|
|
|
|
|
|
32 Byte
|
32 Byte
|
32 Byte
|
32 Byte
|
32 Byte
|
32 Byte
|
|
Yes; M0.0 to M31.7
|
Yes; M0.0 to M31.7
|
Yes; M0.0 to M31.7
|
Yes; M0.0 to M31.7
|
Yes; M0.0 to M31.7
|
Yes; M0.0 to M31.7
|
- of which retentive with battery
|
0 to 255, via super capacitor or battery, adjustable
|
0 to 255, via super capacitor or battery, adjustable
|
0 to 255, via super capacitor or battery, adjustable
|
0 to 255, via super capacitor or battery, adjustable
|
0 to 255, via super capacitor or battery, adjustable
|
0 to 255, via super capacitor or battery, adjustable
|
- of which retentive without battery
|
0 to 112 in EEPROM, adjustable
|
0 to 112 in EEPROM, adjustable
|
0 to 112 in EEPROM, adjustable
|
0 to 112 in EEPROM, adjustable
|
0 to 112 in EEPROM, adjustable
|
0 to 112 in EEPROM, adjustable
|
Configuration
|
|
|
|
|
|
|
- Connectable programming devices/PCs
|
SIMATIC PG/PC, Standard PC
|
SIMATIC PG/PC, Standard PC
|
SIMATIC PG/PC, Standard PC
|
SIMATIC PG/PC, Standard PC
|
SIMATIC PG/PC, Standard PC
|
SIMATIC PG/PC, Standard PC
|
- Central units/expansion units, max.
|
7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.)
|
7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.)
|
7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.)
|
7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.)
|
7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.)
|
7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.)
|
I/O expansions
|
|
|
|
|
|
|
- Analog inputs/outputs, max.
|
35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM)
|
35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM)
|
38; 2 on board inputs and one output, in addition max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM)
|
38; 2 on board inputs and one output, in addition max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM)
|
35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM)
|
35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM)
|
- Digital inputs/outputs, max.
|
168; max. 94 inputs and 74 outputs (CPU+EM)
|
168; max. 94 inputs and 74 outputs (CPU+EM)
|
168; max. 94 inputs and 74 outputs (CPU+EM)
|
168; max. 94 inputs and 74 outputs (CPU+EM)
|
148; max. 128 inputs and 120 outputs (CPU+EM)
|
148; max. 128 inputs and 120 outputs (CPU+EM)
|
- AS interface inputs/outputs, max.
|
62; AS interface A/B slaves (CP 243-2)
|
62; AS interface A/B slaves (CP 243-2)
|
62; AS interface A/B slaves (CP 243-2)
|
62; AS interface A/B slaves (CP 243-2)
|
62; AS interface A/B slaves (CP 243-2)
|
62; AS interface A/B slaves (CP 243-2)
|
Connection system
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
1st interface
|
|
|
|
|
|
|
|
integrated RS 485 interface
|
integrated RS 485 interface
|
integrated RS 485 interface
|
integrated RS 485 interface
|
integrated RS 485 interface
|
integrated RS 485 interface
|
|
RS 485
|
RS 485
|
RS 485
|
RS 485
|
RS 485
|
RS 485
|
Functionality
|
|
|
|
|
|
|
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
MPI
|
|
|
|
|
|
|
|
187.5 kBit/s
|
187.5 kBit/s
|
187.5 kBit/s
|
187.5 kBit/s
|
187.5 kBit/s
|
187.5 kBit/s
|
|
19.2 kBit/s
|
19.2 kBit/s
|
19.2 kBit/s
|
19.2 kBit/s
|
19.2 kBit/s
|
19.2 kBit/s
|
2nd interface
|
|
|
|
|
|
|
|
|
|
integrated RS 485 interface
|
integrated RS 485 interface
|
integrated RS 485 interface
|
integrated RS 485 interface
|
|
|
|
RS 485
|
RS 485
|
RS 485
|
RS 485
|
Functionality
|
|
|
|
|
|
|
|
|
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s
|
|
|
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s
|
|
|
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter
|
MPI
|
|
|
|
|
|
|
|
|
|
187.5 kBit/s
|
187.5 kBit/s
|
187.5 kBit/s
|
187.5 kBit/s
|
|
|
|
19.2 kBit/s
|
19.2 kBit/s
|
19.2 kBit/s
|
19.2 kBit/s
|
CPU/ programming
|
|
|
|
|
|
|
Programming language
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions
|
- User program protection/password protection
|
Yes; 3-stage password protection
|
Yes; 3-stage password protection
|
Yes; 3-stage password protection
|
Yes; 3-stage password protection
|
Yes; 3-stage password protection
|
Yes; 3-stage password protection
|
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms)
|
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer
|
- Number of sub-programs, max.
|
64
|
64
|
64
|
64
|
64
|
64
|
Digital inputs
|
|
|
|
|
|
|
|
14
|
14
|
14
|
14
|
24
|
24
|
Length of cable
|
|
|
|
|
|
|
- Length of cable shielded, max
|
500 m; Standard input: 500m, fast counters: 50m
|
500 m; Standard input: 500m, fast counters: 50m
|
500 m; Standard input: 500m, fast counters: 50m
|
500 m; Standard input: 500m, fast counters: 50m
|
500 m; Standard input: 500m, fast counters: 50m
|
500 m; Standard input: 500m, fast counters: 50m
|
- Length of cable unshielded, max
|
300 m; not for high-speed signals
|
300 m; not for high-speed signals
|
300 m; not for high-speed signals
|
300 m; not for high-speed signals
|
300 m; not for high-speed signals
|
300 m; not for high-speed signals
|
|
Yes; optional, per group
|
Yes; optional, per group
|
Yes; optional, per group
|
Yes; optional, per group
|
Yes; optional, per group
|
Yes; optional, per group
|
Input voltage
|
|
|
|
|
|
|
|
24 V
|
24 V
|
24 V
|
24 V
|
24 V
|
24 V
|
|
0 to 5 V
|
0 to 5 V
|
0 to 5 V; 0 to 1V (I0.3 to I0.5)
|
0 to 5 V 0 to 1V (I0.3 to I0.5)
|
0 to 5 V
|
0 to 5 V
|
|
min. 15 V
|
min. 15 V
|
min. 15 V; at least 4V (I0.3 to I0.5)
|
min. 15 V at least 4V (I0.3 to I0.5)
|
min. 15 V
|
min. 15 V
|
Input current
|
|
|
|
|
|
|
|
2.5 mA
|
2.5 mA
|
2.5 mA; 8 mA for I0.3 to I0.5
|
2.5 mA; 8 mA for I0.3 to I0.5
|
2.5 mA
|
2.5 mA
|
Input delay (at rated value of the input voltage)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Yes; all
|
Yes; all
|
Yes; all
|
Yes; all
|
Yes; all
|
Yes; all
|
|
0.2 ms
|
0.2 ms
|
0.2 ms
|
0.2 ms
|
0.2 ms
|
0.2 ms
|
|
12.8 ms
|
12.8 ms
|
12.8 ms
|
12.8 ms
|
12.8 ms
|
12.8 ms
|
|
|
|
|
|
|
|
|
Yes; I0.0 to I0.3
|
Yes; I0.0 to I0.3
|
Yes; I0.0 to I0.3
|
Yes; I0.0 to I0.3
|
Yes; I0.0 to I0.3
|
Yes; I0.0 to I0.3
|
- for counters/technological functions
|
|
|
|
|
|
|
|
Yes; (E0.0 to E1.5) 30 kHz
|
Yes; (E0.0 to E1.5) 30 kHz
|
Yes; (E0.0 to E1.5) up to 200 kHz
|
Yes; (E0.0 to E1.5) up to 200 kHz
|
Yes; (E0.0 to E1.5) 30 kHz
|
Yes; (E0.0 to E1.5) 30 kHz
|
Digital outputs
|
|
|
|
|
|
|
- Number of digital outputs
|
10; Transistor
|
10; Relay
|
10; Transistor
|
10; Relay
|
16; Transistor
|
16; Relay
|
- Length of cable shielded, max.
|
500 m
|
500 m
|
500 m
|
500 m
|
500 m
|
500 m
|
- Length of cable unshielded, max.
|
150 m
|
150 m
|
150 m
|
150 m
|
150 m
|
150 m
|
- Short-circuit protection of the output
|
No; provided externally
|
No; provided externally
|
No; provided externally
|
No; provided externally
|
No; provided externally
|
No; provided externally
|
- Limitation of voltage induced on circuit interruption to
|
1 W
|
|
1 W
|
|
1 W
|
|
Switching capacity of the outputs
|
|
|
|
|
|
|
|
0.75 A
|
2 A
|
0.75 A
|
2 A
|
0.75 A
|
2 A
|
|
5 W
|
200 W; 30 W DC, 200 W AC
|
5 W
|
200 W; 30 W DC, 200 W AC
|
5 W
|
200 W; 30 W DC, 200 W AC
|
Output voltage
|
|
|
|
|
|
|
|
20 V DC
|
L+/L1
|
L+ minus 0.4V (5V/20,4V for A0.0 to A0.4; 20,4V A0.5 to A1.1)
|
L+/L1
|
20 V DC
|
L+/L1
|
Output current
|
|
|
|
|
|
|
|
750 mA
|
2 A
|
750 mA
|
2 A
|
750 mA
|
2 A
|
- for 0 signal residual current, max.
|
10 ?A
|
0 mA
|
10 ?A
|
0 mA
|
10 ?A
|
0 mA
|
Output delay at resistive load
|
|
|
|
|
|
|
|
15 µs; of the standard outputs, max. (A0.2 to A1.1) 2 µs; of the pulse outputs, max. (A0.0 to A0.1) 2 µs
|
10 ms; all outputs
|
15 µs; of the standard outputs, max. (A0.2 to A1.1) 15 µs; of the pulse outputs, max. (A0.0 to A0.1) 0.5 µs
|
10 ms; all outputs
|
15 µs; of the standard outputs, max. (A0.2 to A1.1) 2 µs; of the pulse outputs, max. (A0.0 to A0.1) 2 µs
|
10 ms; all outputs
|
|
130 µs; of the standard outputs, max. (A0.2 to A1.1) 10 µs; of the pulse outputs, max. (A0.0 to A0.1) 10 µs
|
10 ms; all outputs
|
130 µs; of the standard outputs, max. (A0.2 to A1.1) 130 µs; of the pulse outputs, max. (A0.0 to A0.1) 1.5 µs
|
10 ms; all outputs
|
130 µs; of the standard outputs, max. (A0.2 to A1.1) 10 µs; of the pulse outputs, max. (A0.0 to A0.1) 10 µs
|
10 ms; all outputs
|
Parallel switching of 2 outputs
|
|
|
|
|
|
|
|
Yes
|
No
|
Yes
|
No
|
Yes
|
No
|
Switching frequency
|
|
|
|
|
|
|
- of pulse outputs, at resistive load, max.
|
20 kHz; A0.0 to A0.1
|
1 Hz
|
100 kHz; A0.0 to A0.1
|
1 Hz
|
20 kHz; A0.0 to A0.1
|
1 kHz
|
Summation current of the outputs (per group)
|
|
|
|
|
|
|
|
6 A
|
10 A
|
3.75 A
|
10 A
|
6 A
|
10 A
|
- horizontal installation, up to 55 °C, max.
|
6 A
|
10 A
|
3.75 A
|
10 A
|
6 A
|
10 A
|
Relay outputs
|
|
|
|
|
|
|
- Number of operating cycles
|
|
10,000,000; mechanical 10 million, at rated load voltage 100,000
|
|
10,000,000; mechanical 10 million, at rated load voltage 100,000
|
|
10,000,000; mechanical 10 million, at rated load voltage 100,000
|
Analog inputs
|
|
|
|
|
|
|
- Number of analog potentiometers
|
2; Analog potentiometer; resolution 8 bits
|
2; Analog potentiometer; resolution 8 bits
|
2; Analog potentiometer; resolution 8 bits
|
2; Analog potentiometer; resolution 8 bits
|
2; Analog potentiometer; resolution 8 bits
|
2; Analog potentiometer; resolution 8 bits
|
Sensor supply
|
|
|
|
|
|
|
24 V - sensor supply
|
|
|
|
|
|
|
|
Yes; permissible range: 15.4 to 28.8 V
|
Yes; permissible range: 20.4 to 28.8 V
|
Yes; permissible range: 15.4 to 28.8 V
|
Yes; permissible range: 20.4 to 28.8 V
|
Yes; permissible range: 15.4 to 28.8 V
|
Yes; permissible range: 20.4 to 28.8 V
|
|
Yes; electronic at 280 mA
|
Yes; electronic at 280 mA
|
Yes; electronic at 280 mA
|
Yes; electronic at 280 mA
|
Yes; electronic at 400 mA
|
Yes; electronic at 400mA
|
|
280 mA
|
280 mA
|
280 mA
|
280 mA
|
400 mA
|
400 mA
|
Sensor
|
|
|
|
|
|
|
Connectable encoders
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
- permissible closed-circuit current (2-wire BEROS), max.
|
1 mA
|
1 mA
|
1 mA
|
1 mA
|
1 mA
|
1 mA
|
Integral functions
|
|
|
|
|
|
|
|
6; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 4 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
6; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 4 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
6; fast counters (2 to 200 kHz and 4 to 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 1 to 100 kHz and 3 to 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
6; fast counters (2 to 200 kHz and 4 to 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 1 to 100 kHz and 3 to 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
6; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 4 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
6; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 4 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc.
|
- Count frequency (counters) max.
|
30 kHz
|
30 kHz
|
200 kHz
|
200 kHz
|
30 kHz
|
30 kHz
|
|
4; 4 rising edges and/or 4 falling edges
|
4; 4 rising edges and/or 4 falling edges
|
4; 4 rising edges and/or 4 falling edges
|
4; 4 rising edges and/or 4 falling edges
|
4; 4 rising edges and/or 4 falling edges
|
4; 4 rising edges and/or 4 falling edges
|
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation
|
- Cut-off frequency (pulse)
|
20 kHz
|
20 kHz
|
20 kHz
|
20 kHz
|
20 kHz
|
20 kHz
|
Potentials/ electrical isolation
|
|
|
|
|
|
|
Digital output functions
|
|
|
|
|
|
|
|
Yes; Optocoupler
|
Yes; Relay
|
Yes; Optocoupler
|
Yes; Relay
|
Yes; Optocoupler
|
Yes; Relay
|
- between the channels, in groups of
|
5
|
3, 3 and 4
|
5
|
3, 3 and 4
|
8 and 8
|
4, 5 and 7
|
Digital input functions
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes; Optocoupler
|
- between the channels, in groups of
|
6 and 8
|
6 and 8
|
6 and 8
|
6 and 8
|
13 and 11
|
13 and 11
|
Permissible potential difference
|
|
|
|
|
|
|
- between different circuits
|
500 V DC between 24 V DC and 5 V DC
|
500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC
|
500 V DC between 24 V DC and 5 V DC
|
500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC
|
500 V DC between 24 V DC and 5 V DC
|
500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC
|
Environmental requirements
|
|
|
|
|
|
|
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
For other ambient conditions: see "S7-200 Programmable Controller, System Manual"
|
Operating temperature
|
|
|
|
|
|
|
|
0 °C
|
0 °C
|
0 °C
|
0 °C
|
0 °C
|
0 °C
|
|
45 °C
|
45 °C
|
45 °C
|
45 °C
|
45 °C
|
45 °C
|
- horizontal mounting, min.
|
0 °C
|
0 °C
|
0 °C
|
0 °C
|
0 °C
|
0 °C
|
- horizontal mounting, max.
|
55 °C
|
55 °C
|
55 °C
|
55 °C
|
55 °C
|
55 °C
|
Air pressure
|
|
|
|
|
|
|
|
860 hPa
|
860 hPa
|
860 hPa
|
860 hPa
|
860 hPa
|
860 hPa
|
|
1,080 hPa
|
1,080 hPa
|
1,080 hPa
|
1,080 hPa
|
1,080 hPa
|
1,080 hPa
|
Relative humidity
|
|
|
|
|
|
|
|
5 %
|
5 %
|
5 %
|
5 %
|
5 %
|
5 %
|
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
95 %; RH stressing level 2 in accordance with IEC 1131-2
|
Degree of protection and class of protection
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Dimensions and weight
|
|
|
|
|
|
|
|
360 g
|
410 g
|
390 g
|
440 g
|
550 g
|
660 g
|
|
120.5 mm
|
120.5 mm
|
140 mm
|
140 mm
|
196 mm
|
196 mm
|
|
80 mm
|
80 mm
|
80 mm
|
80 mm
|
80 mm
|
80 mm
|
|
62 mm
|
62 mm
|
62 mm
|
62 mm
|
62 mm
|
62 mm
|
|
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
|