Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Power output modules

Type

LA716

LA716I

LA716I HP

Supply voltage

For control unit

Provided internally via the bus module

Power outputs

Number per power output module

16

16

8

Electrical isolation

  • To the control unit

By means of opto-triac and optocoupler specified according to EN 60747-5-2

  • Of power outputs from each other

no

no

no

Load voltage

  • Rated value

230 V AC

230 V AC

230 V AC

  • Permissible range

187 ... 264 V (TN system)

187 ... 264 V (TN system)

187 ... 264 V (TN system)

  • Frequency

50/60 Hz (47 ... 63 Hz)

50/60 Hz (47 ... 63 Hz)

50/60 Hz (47 ... 63 Hz)

Output voltage

Full waves switched during the zero crossover

Output current per phase, max.

23 A

32 A

32 A

Output current per output

  • Rated value

2.8 A

5 A

10 A

  • Permissible range

0.1 to 2.8 A

0.1 to 5 A

0.1 to 10 A

  • Residual current

10 mA

10 mA

10 mA

Switching capacity per channel at 230 V, max.

650 W

1,150 W

2,300 W

Resolution at the power outputs

1%

1%

1%

Loads

  • Load type

Resistive load with a maximum of 15 times the cold current in the first half wave. (In the case of flash emitters, this can lead to a reduction of the permissible switching capacity. These emitters can be measured at Siemens.)

  • Overload

5 times the rated current for 20 ms

Protective measures

  • Thermal monitoring

Yes (by NTC thermistor)

Yes (by NTC thermistor)

Yes (by NTC thermistor)

  • Response threshold

-93 °C ±5 K

-93 °C ±5 K

-93 °C ±5 K

  • Short-circuit protection

One fast blow 5 A/250 V fuse per output

One fast blow 5 A/250 V fuse per output

One fast blow 10 A/250 V fuse per output

  • Overvoltage protection

Yes

Yes

Yes

Connecting cables

  • ResistanceRmax.

14  (to guarantee continued short-circuit protection)

14  (to guarantee continued short-circuit protection)

14  (to guarantee continued short-circuit protection)

Mechanical data

Degree of protection according to DIN 40050

IP00

IP00

IP00

Dimensions (W x H x D)

31 mm x 233.4 mm x 250 mm

31 mm x 233.4 mm x 252 mm (without mating connector)

31 mm x 233.4 mm x 252 mm (without mating connector)
























































Каталог оборудования

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366