The power output modules are an important component of the heater control.
Three different power output modules can be used depending on the application:
- LA716 – the universal version:
It provides 16 channels for connecting resistive loads. Up to 650 W can be used per output channel. - LA716I – the innovative version:
It also provides 16 channels for connecting resistive loads. Up to 1,150 W can be used per output channel here. - LA716I HP – the high-power version:
It provides 8 channels for connecting resistive loads. Up to 2,300 W can be used per output channel.
LA716 power output module
LA716I power output module
LA716I HP power output module