Order No. |
6GK5 104-2BB00-2AA3 |
6GK5 106-1BB00-2AA3 |
6GK5 108-0BA00-2AA3 |
6GK5 108-0PA00-2AA3 |
Product type designation |
SCALANCE X104-2 |
SCALANCE X106-1 |
SCALANCE X108 |
SCALANCE X108PoE |
Transmission rate |
||||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Interfaces |
||||
Number of electrical/optical connections for network components or terminal equipment maximum |
6 |
7 |
8 |
8 |
Number of electrical connections |
||||
|
4 |
6 |
8 |
6 |
|
- |
- |
- |
2 |
|
1 |
1 |
1 |
1 |
|
1 |
1 |
1 |
1 |
|
1 |
1 |
1 |
1 |
Design of electrical connection |
||||
|
RJ45 port |
RJ45 port |
RJ45 port |
RJ45 port |
|
- |
- |
- |
RJ45 port |
|
2-pole terminal block |
2-pole terminal block |
2-pole terminal block |
2-pole terminal block |
|
4-pole terminal block |
4-pole terminal block |
4-pole terminal block |
4-pole terminal block |
Number of optical interfaces for optical waveguide |
||||
|
- |
- |
- |
- |
|
2 |
1 |
- |
- |
Design of optical interface for optical waveguide |
||||
|
- |
- |
- |
- |
|
BFOC sockets (multimode up to 5 km) |
BFOC sockets (multimode up to 5 km) |
- |
- |
Connectable optical power relative to 1 mW |
||||
|
-19 … -14 dB |
-19 … -14 dB |
- - |
- - |
|
-14 dB |
-14 dB |
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-32 dB |
-32 dB |
- |
- |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
0 dB |
- |
- |
Range at the optical interface depending on the optical fiber used |
0 … 5 km |
0 … 5 km |
- - |
- - |
Inputs/outputs |
||||
Operating current of signaling contacts at AC maximum |
- |
- |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
0.1 A |
0.1 A |
Supply voltage, current consumption, power loss |
||||
Type of voltage of supply voltage |
DC |
DC |
DC |
DC |
Supply voltage external |
24 V |
24 V |
24 V |
24 V |
|
18 V |
18 V |
18 V |
18 V |
|
32 V |
32 V |
32 V |
32 V |
Product component fusing at power supply input |
Yes |
Yes |
Yes |
Yes |
Type of fusing at input for supply voltage |
4 A / 125 V |
|||
Consumed current maximum |
0.16 A |
0.15 A |
0.14 A |
1.7 A |
Active power loss at 24 V for DC |
3.8 W |
3.6 W |
3.36 W |
10 W |
Permitted ambient conditions |
||||
Ambient temperature |
||||
|
-10 … +60 °C |
-10 … +60 °C |
-20 … +70 °C |
-20 … +60 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
95 % |
Protection class IP |
IP30 |
IP30 |
IP30 |
IP30 |
Design, dimensions and weight |
||||
Design |
Compact |
Compact |
Compact |
Compact |
Width |
60 mm |
60 mm |
60 mm |
60 mm |
Height |
125 mm |
125 mm |
125 mm |
125 mm |
Depth |
124 mm |
124 mm |
124 mm |
124 mm |
Net weight |
0.78 kg |
0.78 kg |
0.78 kg |
0.9 kg |
Type of mounting |
||||
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
- |
Product properties, functions, componentsgeneral |
||||
Cascading in cases of star structuring |
- |
- |
- |
- |
Standards, specifications, approvals |
||||
Standard |
||||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
|
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
|
EN 61000-6-4 (Class A) |
EN 61000-6-4 (Class A) |
EN 61000-6-4 (Class A) |
EN 61000-6-4:2001 |
|
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2:2001 |
Verification of suitability |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
|
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
|
- |
- |
- |
- |
|
- |
- |
- |
- |
Marine classification association |
||||
|
Yes |
Yes |
Yes |
No |
|
Yes |
Yes |
Yes |
No |
|
Yes |
Yes |
Yes |
No |
|
Yes |
Yes |
Yes |
No |
|
Yes |
Yes |
Yes |
No |
|
Yes |
Yes |
Yes |
No |
Marine classification association/ Polski Rejestr Statkow (PRS) |
Yes |
Yes |
Yes |
No |
Order No. |
6GK5 112-2BB00-2AA3 |
6GK5 116-0BA00-2AA3 |
6GK5 124-0BA00-2AA3 |
Product type designation |
SCALANCE X112-2 |
SCALANCE X116 |
SCALANCE X124 |
Transmission rate |
|||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Interfaces |
|||
Number of electrical/optical connections for network components or terminal equipment maximum |
14 |
16 |
24 |
Number of electrical connections |
|||
|
12 |
16 |
24 |
|
- |
- |
- |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
Design of electrical connection |
|||
|
RJ45 port |
RJ45 port |
RJ45 port |
|
- |
- |
- |
|
2-pole terminal block |
2-pole terminal block |
2-pole terminal block |
|
4-pole terminal block |
4-pole terminal block |
4-pole terminal block |
Number of optical interfaces for optical waveguide |
|||
|
- |
- |
- |
|
2 |
- |
- |
Design of optical interface for optical waveguide |
|||
|
- |
- |
- |
|
BFOC sockets (multimode up to 5 km) |
- |
- |
Connectable optical power relative to 1 mW |
|||
|
-19 … -14 dB |
- - |
- - |
|
-14 dB |
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-32 dB |
- |
- |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
- |
- |
Range at the optical interface depending on the optical fiber used |
0 … 5 km |
- - |
- - |
Inputs/outputs |
|||
Operating current of signaling contacts at AC maximum |
- |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
0.1 A |
Supply voltage, current consumption, power loss |
|||
Type of voltage of supply voltage |
DC |
DC |
DC |
Supply voltage external |
24 V |
24 V |
24 V |
|
18 V |
18 V |
18 V |
|
32 V |
32 V |
32 V |
Product component fusing at power supply input |
No |
No |
No |
Type of fusing at input for supply voltage |
- |
- |
- |
Consumed current maximum |
0.45 A |
0.3 A |
0.45 A |
Active power loss at 24 V for DC |
5.16 W |
4.4 W |
4.8 W |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-10 … +70 °C |
-20 … +70 °C |
-20 … +70 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
Protection class IP |
IP30 |
IP30 |
IP30 |
Design, dimensions and weight |
|||
Design |
Compact |
Compact |
Compact |
Width |
120 mm |
120 mm |
180 mm |
Height |
125 mm |
125 mm |
125 mm |
Depth |
124 mm |
124 mm |
124 mm |
Net weight |
1.1 kg |
1.1 kg |
1.5 kg |
Type of mounting |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
Product properties, functions, componentsgeneral |
|||
Cascading in cases of star structuring |
- |
- |
- |
Standards, specifications, approvals |
|||
Standard |
|||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
|
EN 60079-0:2006, EN60079-15:2005, II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X |
EN 60079-0:2006, EN60079-15:2005, II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X |
EN 60079-0:2006, EN60079-15:2005, II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
|
EN 61000-6-4:2001 |
EN 61000-6-4:2001 |
EN 61000-6-4:2001 |
|
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
Verification of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
- |
- |
- |
|
- |
- |
- |
Marine classification association |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
No |
No |
No |
|
No |
No |
No |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
No |