Control Module

For general technical data, see section "DC Converters"

Type

6RA8000-0MV62-0AA0

Rated armature supply voltage that can be sensed

V

50/125/250/575/1 000

Rated supply voltage, electronics power supply

V

24 DC (18 … 30 V DC);In = 5 A

Rated field supply voltage1)

V

480 V 2 AC (+10/-20 %)

Rated frequency

Hz

45 … 65

Rated DC field voltage 1)

V

Max. 390

Rated DC field current

A

40

Normal ambient temperature in operation

°C

0 … +55

Dimensions

  • Width

mm

271

  • Height

mm

388

  • Depth

mm

253

Weight, approx.

kg

12


1) The field supply voltage can lie below the rated field voltage (set using a parameter, input voltages of up to 85 V are permissible). The output voltage decreases accordingly. The specified DC output voltage can be reliably provided up to a 5 % undervoltage of the line supply voltage (rated field supply voltage).