Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
SINVERT PVM10 |
SINVERT PVM13 |
SINVERT PVM17 |
||
---|---|---|---|---|
Output data (AC) |
||||
Rated voltage |
V |
400 3 AC |
400 3 AC |
400 3 AC |
Rated voltage |
V |
0.8 Vac,r ... 1.2 Vac,r |
0.8 Vac,r ... 1.2 Vac,r |
0.8 Vac,r ... 1.2 Vac,r |
Rated frequency |
Hz |
50 |
50 |
50 |
Rated frequency |
Hz |
0.95 fr ... 1.02 fr |
0.95 fr ... 1.02 fr |
0.95 fr ... 1.02 fr |
Rated power |
kW |
10.0 (at 600 V DC / cos 1) |
12.4 (at 600 V DC / cos 1) |
16.5 (at 600 V DC / cos 1) |
Power, max. |
kW |
10.0 |
12.4 |
16.5 |
Output current, max. |
A |
18 |
18 |
25 |
cos |
1 (0.9i … 0.9c) |
1 (0.9i … 0.9c) |
1 (0.9i … 0.9c) |
|
THD I |
% |
< 2.5 |
< 2.5 |
< 2.5 |
Line system configuration |
TN-S |
TN-S |
TN-S |
|
Backup fuse |
A |
32 (type B) |
32 (type B) |
32 (type B) |
Overvoltage protection (internal) |
Type 3 |
Type 3 |
Type 3 |
|
Input data (DC) |
||||
MPP voltage rangeVmpp min - |
V |
380 … 850 |
420 … 850 |
525 … 850 |
Start input voltage |
V |
350 |
350 |
350 |
Input voltage, max. |
V |
1000 |
1000 |
1000 |
Maximum voltage for operationVdc,op |
V |
950 |
950 |
|
Minimum voltage for operationVdc,min |
V |
350 |
350 |
|
Nominal input powerPdc,r |
kW |
10.2 (at 600 V DC) |
12.6 (at 600 V DC) |
16.8 (at 600 V DC) |
Input current, max.Idc max |
A |
29 |
30 |
32 |
Number of DC inputs |
4 |
4 |
4 |
|
Current per input, max. |
A |
25 |
25 |
25 |
DC disconnector |
Integrated |
Integrated |
Integrated |
|
Overvoltage protection (internal) |
Type 3 |
Type 3 |
Type 3 |
|
Efficiency |
||||
Efficiency, European |
% |
97.4 |
97.5 |
97.7 |
Efficiency, max. |
% |
98.0 |
98.0 |
98.0 |
Power loss in night-time operation |
W |
0.5 |
0.5 |
0.5 |
Minimum DC power for operation |
W |
60 |
60 |
60 |
Dimensions |
||||
|
mm |
530 |
530 |
530 |
|
mm |
601 |
601 |
601 |
|
mm |
270 |
270 |
270 |
Weight |
kg |
40 |
40 |
40 |
1) The specified values describe the technical properties of the device. The threshold values required for line monitoring are set at the installation location during commissioning and can deviate from the values specified in the table.
SINVERT PVM10 |
SINVERT PVM13 |
SINVERT PVM17 |
||
---|---|---|---|---|
Technical data, general |
||||
Galvanic isolation |
Not applicable (transformerless topology) |
Not applicable (transformerless topology) |
Not applicable (transformerless topology) |
|
Operating noise level |
dB(A) |
< 45 |
< 45 |
< 45 |
Installation altitude, max. (without derating) |
m |
2000 |
2000 |
2000 |
Installation location |
Suitable for outdoor installation |
Suitable for outdoor installation |
Suitable for outdoor installation |
|
Type of mounting |
Wall mounting |
Wall mounting |
Wall mounting |
|
Cooling method |
Natural convection |
Natural convection |
Natural convection |
|
Enclosure color |
RAL 7035 (light grey) |
RAL 7035 (light grey) |
RAL 7035 (light grey) |
|
Standards and conformity, applicable |
||||
Conformity |
CE |
CE |
CE |
|
Line monitoring (ENS) |
VDE 0126-1-1 |
VDE 0126-1-1 |
VDE 0126-1-1 |
|
Safety |
EN 50178 |
EN 50178 |
EN 50178 |
|
EMC immunity |
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
|
EMC interference emission |
EN 61000-6-4 |
EN 61000-6-4 |
EN 61000-6-4 |
|
Harmonics |
EN 61000-3-12 |
EN 61000-3-12 |
EN 61000-3-12 |
|
Flicker |
EN 61000-3-11 |
EN 61000-3-11 |
EN 61000-3-11 |
|
Degree of protection |
IP65 (EN 60529) |
IP65 (EN 60529) |
IP65 (EN 60529) |
|
Protection class |
I |
I |
I |
|
Ports |
||||
Input DC |
MC4 connector (not included in scope of supply) |
MC4 connector (not included in scope of supply) |
MC4 connector (not included in scope of supply) |
|
Output AC2) |
Connector (included in scope of supply) Max. 6 mm2 finely stranded Max. 18 mm cable diameter |
Connector (included in scope of supply) Max. 6 mm2 finely stranded Max. 18 mm cable diameter |
Connector (included in scope of supply) Max. 6 mm2 finely stranded Max. 18 mm cable diameter |
|
Communication Ethernet |
Connector (included in scope of supply) |
Connector (included in scope of supply) |
Connector (included in scope of supply) |
|
Communication RS485 |
Connector (included in scope of supply, 2 units) |
Connector (included in scope of supply, 2 units) |
Connector (included in scope of supply, 2 units) |
|
Radiation sensor |
Connector (included in scope of supply) |
Connector (included in scope of supply) |
Connector (included in scope of supply) |
|
Relay output - fault |
Connector (included in scope of supply) |
Connector (included in scope of supply) |
Connector (included in scope of supply) |
|
Ambient conditions, climatic |
||||
Ambient temperature during operation |
°C |
-25 ... 55 |
-25 ... 55 |
-25 ... 55 |
Ambient temperature during storage and transport |
°C |
-25 ... 70 |
-25 ... 70 |
-25 ... 70 |
Temperature for maximum performance, max. |
°C |
50 |
50 |
45 |
Humidity, relative |
% |
4 ... 100 |
4 ... 100 |
4 ... 100 |
Other climatic conditions in accordance with class |
4K4H |
4K4H |
4K4H |
2) A connector for a max. cable cross-section of 10 mm2 and max. 24 mm cable diameter is optionally available.
SINVERT PVM10 |
SINVERT PVM13 |
SINVERT PVM17 |
||
---|---|---|---|---|
Operator panel |
||||
Display, type |
Graphic (with backlighting) |
Graphic (with backlighting) |
Graphic (with backlighting) |
|
Display, resolution |
Pixels |
128 x 64 |
128 x 64 |
128 x 64 |
Operation |
Membrane keyboard, 8 keys |
Membrane keyboard, 8 keys |
Membrane keyboard, 8 keys |