Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Order No. |
6GK1 562-1AA00 |
6GK1 562-1AM00 |
Product type designation |
CP 5621 |
CP 5621 MPI |
Transmission rate |
||
Transmission rate at interface 1 in accordance with PROFIBUS |
9.6 Kbit/s … 12 Mbit/s |
9.6 Kbit/s … 12 Mbit/s |
Interfaces |
||
Number of electrical connections at interface 1 in accordance with PROFIBUS |
1 |
1 |
Design of electrical connection |
||
|
9-pin D-sub socket (RS 485) |
9-pin D-sub socket (RS 485) |
|
PCI Express x1 |
PCI Express x1 |
Supply voltage, current consumption, power loss |
||
Type of power supply |
DC |
DC |
Power supply |
||
|
3.3 V |
3.3 V |
|
12 V |
12 V |
Relative symmetrical tolerance |
||
|
9 % |
9 % |
|
8 % |
8 % |
Current consumed |
||
|
0.4 A |
0.4 A |
|
0.18 A |
0.18 A |
Effective power loss |
2.2 W |
2.2 W |
Permitted ambient conditions |
||
Ambient temperature |
||
|
5 … 55 °C |
5 … 55 °C |
|
-20 … +60 °C |
-20 … +60 °C |
|
-20 … +60 °C |
-20 … +60 °C |
Relative humidity at 25 °C without condensation during operation, maximum |
85 % |
85 % |
IP degree of protection |
IP00 |
IP00 |
Design, dimensions and weights |
||
Module format |
PCI Express x1 |
PCI Express x1 |
Width |
18 mm |
18 mm |
Height |
111 mm |
111 mm |
Depth |
129 mm |
129 mm |
Net weight |
100 g |
100 g |
Product properties, functions, componentsGeneral |
||
Number of plug-in cards of same design which can be inserted per PC station |
1 |
1 |
Number of modules - Note |
- |
- |
Performance data |
||
Performance dataOpen communication |
||
Software required for open communication by means of SEND/RECEIVE |
Yes, SOFTNET-PB DP / SOFTNET-PB DP slave / SOFTNET-PB S7 |
Yes, SOFTNET-PB DP / SOFTNET-PB DP slave / SOFTNET-PB S7 |
Number of possible connections for open communication by means of SEND/RECEIVE, maximum |
50 |
50 |
Performance data PROFIBUS DP |
||
Software required for DP master function |
Yes, SOFTNET-PB DP |
Yes, SOFTNET-PB DP |
Service as DP master |
||
|
Yes |
Yes |
|
No |
No |
|
No |
No |
Number of DP slaves operable on DP master |
64 |
64 |
Data volume |
||
|
14 640 bytes |
14 640 bytes |
|
14 640 bytes |
14 640 bytes |
|
244 bytes |
244 bytes |
|
244 bytes |
244 bytes |
|
244 bytes |
244 bytes |
Software required for DP slave function |
Yes, SOFTNET-PB DP Slave |
Yes, SOFTNET-PB DP Slave |
Service as DP slave |
||
|
Yes |
Yes |
|
No |
No |
Data volume |
||
|
122 bytes |
122 bytes |
|
122 bytes |
122 bytes |
Performance dataS7 communication |
||
Software required for S7 communication |
Yes, SOFTNET-PB S7 |
Yes, SOFTNET-PB S7 |
Number of possible connections for S7/PG communication, maximum |
8 |
8 |
Performance dataMultiprotocol operation |
||
Number of configurable connections per PC station |
207 |
207 |
Product functionsManagement, configuration, programming |
||
Configuration software required |
NCM PC included in scope of delivery of required software product |
NCM PC included in scope of delivery of required software product |
Product functions Diagnostics |
||
Product function: Port diagnostics |
Yes |
Yes |
Standards, specifications, approvals |
||
Standard |
||
|
2004/108/EC |
89/336/EEC |
|
CAN/CSA C22.2 & UL 60950-1, UL 508 |
CAN/CSA C22.2 & UL 60950-1, UL 508 |
|
EN 61000-6-3, EN 61000-6-4 |
EN 61000-6-3, EN 61000-6-4 |
|
EN 61000-6-1, EN 61000-6-2 |
EN 61000-6-1, EN 61000-6-2 |
Certificate of suitability |
||
|
Yes |
Yes |
|
Yes |
Yes |
Accessories |
||
Accessories |
Optional: MPI cable |
Included in scope of delivery: MPI cable |