Climatic conditions |
|
Ambient temperature |
5 ... 50 °C |
Relative humidity |
70 %, non-condensing |
Corrosive atmosphere |
No |
Gas inlet conditions |
|
|
|
|
800 ... 1 100 hPa (absolute) |
|
30 ... 90 l/h (0.5 … 1.5 l/min) |
|
0 ... 50 °C |
|
|
|
55 000 hPa (absolute) |
|
30 … 90 l/h (0.5 … 1.5 l/min) |
|
0 … 50 °C |
Power supply |
|
|
200 ... 240 V AC |
|
100 ... 120 V AC |
|
24 V DC for switch amplifiers |
Power supply, frequency |
|
|
47 ... 63 Hz |
|
47 ... 63 Hz |
|
Not specified |
Type of connections |
|
Pipe material |
Stainless steel |
Connections/components |
|
Cabling |
|
Electrical design |
According to IEC |
Type of cables |
Non-armored cables |
Cable ID |
No single core labeling |
Installation |
|
Site |
Interior |
Ex-zone analyzer |
ATEX II, 3G |
System design |
|
Version |
Cabinet |
Degree of protection |
IP54 |
Automatic calibration |
No |
Signal outputs |
4 ... 20 mA/isolated contact |
With sample gas return flow |
On request |
Measuring response(relating to sample gas pressure 1 013 hPa absolute, 0.5 l/min sample gas flow and 25 °C ambient temperature) |
|
Output signal fluctuation |
< ± 0.75% of the smallest possible measuring range according to rating plate, with electronic damping constant of 1 s ( = 0.25%) |
Zero point drift |
< 1%/week of the smallest possible span according to rating plate |
Measured-value drift |
< 0.5%/of the smallest possible span according to rating plate |
Repeatability |
< 1 % of the current measuring range |
Detection limit |
1 % of the current measuring range |
Linearity error |
< ± 1 % of the current measuring range |
Influencing variable(relating to sample gas pressure 1 013 hPa absolute, 0.5 l/min sample gas flow and 25 °C ambient temperature) |
|
Ambient temperature |
< 1%/10 K referred to smallest possible span according to label |
Carrier gases |
Deviation from zero point |
Sample gas flow |
< 0.1% of the smallest possible span according to rating plate with a change in flow of 0.1 l/h within the permissible flow range |
Sample gas pressure |
< 1 % of the current measuring range with a pressure change of 100 hPa |
Power supply |
< 0.1 % of the current measuring range with rated voltage ± 10 % |
Generator gas analyzer
Analysis |
Measuring point designation |
Generator gas analyzer |
|||||
---|---|---|---|---|---|---|---|
Concentration |
Unit |
Measured component |
Measuring range |
||||
Component |
Min. |
Typical |
Max. |
Small |
Large |
||
Ar/CO2 in air |
0 |
100 |
vol. % |
Yes |
0 |
100 |
|
H2 in Ar/CO2 |
0 |
100 |
vol. % |
Yes |
0 |
100 |
|
H2 in air |
80 |
100 |
vol. % |
Yes |
80 |
100 |
|
Sample temperature |
50 |
°C |
|||||
Dust content |
0 |
mg/m3 |
|||||
H2O dew point |
-50 |
°C |
|||||
Aggregate state, sample1) |
Gaseous |
1) Standard state at 20 °C, 101.3 kPa