6XV1 874-2A |
6XV1 874-2B |
|
Product type designation |
POF Standard Cable GP |
POF Trailing Cable |
Product description |
Fiber-optic cable with poly-optical fiber, sold by the meter, non-assembled |
Fiber-optic cable with poly-optical fiber, sold by the meter, non-assembled |
Suitability for application |
Cable for fixed installation indoors, UL approval |
Cable for moving applications (e.g. trailing cables) |
Design of preassembled FO cable |
Can be fitted with SC RJ or SC RJ Plug PRO connectors |
Can be fitted with SC RJ or SC RJ Plug PRO connectors |
Cable designation |
I-V4Y(ZN)Y 2P 980/1000 |
I-V4Y(ZN)11Y 2P 980/1000 FLEX UL |
Cable length |
- |
- |
Optical data |
||
Maximum damping factor per length at 650 nm |
0.16 dB/m |
0.18 dB/m |
Bandwidth length product at 650 nm |
1 GHz·m |
1 GHz·m |
Mechanical data |
||
Number of fibers per FO core |
1 |
1 |
Number of FO cores per FO cable |
2 |
2 |
Design of FO fiber |
Plastic optical fiber 980/1000 µm |
Plastic optical fiber 980/1000 µm |
Design of FO core |
- |
- |
Design of FO cable |
- |
- |
Outer diameter |
||
|
980 µm |
980 µm |
|
1 000 µm |
1 000 µm |
|
2.2 mm |
2.2 mm |
|
7.8 mm |
8 mm |
Symmetrical deviation |
||
|
0.1 mm |
0.1 mm |
|
- |
- |
Width of cable sheath |
- |
- |
Symmetrical tolerance of cable sheath width |
- |
- |
Thickness of cable sheath |
- |
- |
Symmetrical tolerance of cable sheath thickness |
- |
- |
Material |
||
|
Polymethylmethacrylate (PMMA) |
Polymethylmethacrylate (PMMA) |
|
Fluoridated special polymer |
Fluoridated special polymer |
|
PA |
PA |
|
PVC |
PUR |
|
Kevlar fibers |
Kevlar fibers |
Color |
||
|
Orange/black |
Orange/black |
|
Green |
Green |
Bending radius |
||
|
100 mm |
60 mm |
|
150 mm |
60 mm |
|
- |
0.04 m |
Number of bending cycles |
- |
5 000 000 |
Maximum tensile load |
100 N |
100 N |
Short-term lateral force per length |
100 N/cm |
200 N/cm |
Continuous lateral force per length |
- |
20 N/cm |
Weight per length |
65 kg/km |
55 kg/km |
Permitted ambient conditions |
||
Ambient temperature |
||
|
-30 … +70 °C |
-20 … +70 °C |
|
-30 … +70 °C |
-40 … +80 °C |
|
-30 … +70 °C |
-40 … +80 °C |
|
0 … 50 °C |
5 … 50 °C |
Ambient conditions for operation |
- |
- |
IP degree of protection |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-1-2 |
Flame-retardant in accordance with IEC 60332-1-2 |
Chemical resistance |
||
|
Limited resistance |
Resistant |
|
Limited resistance |
Resistant |
|
- |
- |
Radiological resistance against UV radiation |
Not resistant |
Resistant |
Product properties, functions, componentsGeneral |
||
Product property |
||
|
No |
No |
|
Yes |
Yes |
Product component: protection against rodents |
No |
No |
Cable length with plastic optical fiber |
||
|
50 m |
50 m |
|
- |
- |
Standards, specifications, approvals |
||
Certificate of suitability |
UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN (CSA standard C22.2 No232-M1988) |
UL-758 AWM Style 5422 |
|
Yes |
Yes |
Order No. |
6XV1 861-2A |
6XV1 861-2C |
6XV1 861-2D |
Product type designation |
PCF Standard Cable GP |
PCF Trailing Cable |
PCF Trailing Cable GP |
Product description |
Polymer cladded fiber cable, sold by the meter, non-assembled |
Polymer cladded fiber cable, sold by the meter, non-assembled |
Polymer cladded fiber cable, sold by the meter, non-assembled |
Suitability for application |
Cable for fixed installation for indoor and outdoor use, UL approval |
Cable for use with high mechanical stress and moving applications (e.g. trailing cables), without UL approval |
Cable for use with high mechanical stress and moving applications (e.g. trailing cables), UL approval |
Design of preassembled FO cable |
Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors |
Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors |
Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors |
Cable designation |
AT-V(ZN)YY 2K 200/230 |
AT-V(ZN)Y(ZN)11Y 2K 200/230 |
AT-V(ZN)Y(ZN)Y 2K 200/230 |
Cable length |
- |
- |
- |
Optical data |
|||
Maximum damping factor per length at 660 nm |
10 dB/km |
10 dB/km |
10 dB/km |
Bandwidth length product at 650 nm |
17 GHz·m |
17 GHz·m |
17 GHz·m |
Mechanical data |
|||
Number of fibers per FO core |
1 |
1 |
1 |
Number of FO cores per FO cable |
2 |
2 |
2 |
Design of FO fiber |
Step index fiber 200/230 µm |
Step index fiber 200/230 µm |
Step index fiber 200/230 µm |
Design of FO core |
- |
- |
- |
Design of FO cable |
- |
- |
- |
Outer diameter |
|||
|
200 µm |
200 µm |
200 µm |
|
230 µm |
230 µm |
230 µm |
|
2.2 mm |
2.2 mm |
2.2 mm |
|
7.2 mm |
8.8 mm |
8.8 mm |
Symmetrical deviation |
|||
|
0.1 mm |
0.1 mm |
0.1 mm |
|
0.5 mm |
0.5 mm |
0.5 mm |
Width of cable sheath |
- |
- |
- |
Symmetrical tolerance of cable sheath width |
- |
- |
- |
Thickness of cable sheath |
- |
- |
- |
Symmetrical tolerance of cable sheath thickness |
- |
- |
- |
Material |
|||
|
Quartz glass |
Quartz glass |
Quartz glass |
|
Special polymer |
Special polymer |
Special polymer |
|
PVC |
PVC |
PVC |
|
PVC |
PUR |
PVC |
|
Aramide fibers |
Aramide fibers |
Aramide fibers |
Color |
|||
|
Orange/black |
Orange/black |
Orange/black |
|
Green |
Green |
Green |
Bending radius |
|||
|
70 mm |
130 mm |
130 mm |
|
105 mm |
175 mm |
175 mm |
|
- |
- |
- |
Number of bending cycles |
- |
5 000 000 |
5 000 000 |
Maximum tensile load |
100 N |
800 N |
800 N |
Short-term lateral force per length |
500 N/cm |
500 N/cm |
500 N/cm |
Continuous lateral force per length |
300 N/cm |
300 N/cm |
300 N/cm |
Weight per length |
45 kg/km |
85 kg/km |
85 kg/km |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-40 … +90 °C |
-25 … +75 °C |
-25 … +75 °C |
|
-40 … +90 °C |
-30 … +75 °C |
-30 … +75 °C |
|
-40 … +90 °C |
-30 … +75 °C |
-30 … +75 °C |
|
-5 … +50 °C |
-5 … +50 °C |
-5 … +50 °C |
Ambient conditions for operation |
- |
- |
- |
IP degree of protection |
- |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-1-2 and IEC 60332-3-22 (Cat. A) |
Flame-retardant |
Flame-retardant in accordance with IEC 60332-1-2 and IEC 60332-3-22 (Cat. A) |
Chemical resistance |
|||
|
Limited resistance |
Resistant |
Limited resistance |
|
Limited resistance |
Resistant |
Limited resistance |
|
- |
- |
- |
Radiological resistance against UV radiation |
Resistant |
Resistant |
Resistant |
Product properties, functions, componentsGeneral |
|||
Product property |
|||
|
No |
No |
No |
|
Yes |
Yes |
Yes |
Product component: protection against rodents |
No |
No |
No |
Cable length with polymer cladded fiber |
|||
|
100 m |
100 m |
100 m |
|
400 m |
400 m |
400 m |
Standards, specifications, approvals |
|||
Certificate of suitability |
UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN 90 Cel, FT1, FT4 (CSA standard C22.2 No232-M1988) |
- |
UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN 90 Cel, FT1, FT4 (CSA standard C22.2 No232-M1988) |
|
Yes |
Yes |
Yes |