Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Order No. |
6GK5 101-1BB00-2AA3 |
6GK5 101-1BC00-2AA3 |
Product type designation |
SCALANCE X101-1 |
SCALANCE X101-1LD |
Transmission rate |
||
Transfer rate 1 |
- |
- |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
Interfaces |
||
Number of electrical/optical connections for network components or terminal equipment maximum |
2 |
2 |
Number of electrical connections |
||
|
1 |
1 |
|
- |
- |
|
1 |
1 |
|
1 |
1 |
|
1 |
1 |
Design of electrical connection |
||
|
RJ45 port |
RJ45 port |
|
- |
- |
|
2-pole terminal block |
2-pole terminal block |
|
4-pole terminal block |
4-pole terminal block |
Number of optical interfaces for optical waveguide |
||
|
- |
- |
|
1 |
1 |
Design of optical interface for optical waveguide |
||
|
- |
- |
|
BFOC sockets (multimode up to 5 km) |
BFOC port (singlemode up to 26 km) |
Connectable optical power relative to 1 mW |
||
|
-14 dB |
0 dB |
|
-14 … -19 dB |
0 … -5 dB |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-31 dB |
-35 dB |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
0 dB |
Range at the optical interface depending on the optical fiber used |
0 … 5 km |
0 … 26 km |
Inputs/outputs |
||
Operating current of signaling contacts at AC maximum |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
Supply voltage, current consumption, power loss |
||
Type of voltage of supply voltage |
DC |
DC |
Supply voltage external |
24 V |
24 V |
|
18 V |
18 V |
|
32 V |
32 V |
Product component fusing at power supply input |
Yes |
Yes |
Type of fusing at input for supply voltage |
||
Consumed current maximum |
0.12 A |
0.12 A |
Active power loss at 24 V for DC |
3 W |
3 W |
Permitted ambient conditions |
||
Ambient temperature |
||
|
-10 … +60 °C |
-10 … +60 °C |
|
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
Protection class IP |
IP30 |
IP30 |
Design, dimensions and weight |
||
Design |
Compact |
Compact |
Width |
40 mm |
40 mm |
Height |
125 mm |
125 mm |
Depth |
124 mm |
124 mm |
Net weight |
0.55 kg |
0.55 kg |
Type of mounting |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Type of mounting |
- |
- |
Product properties, functions, componentsgeneral |
||
Cascading in cases of star structuring |
- |
- |
Standards, specifications, approvals |
||
Standard |
||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
|
EN 600079-15 II 3 G EEx nA II T.. KEMA 06 ATEX 0021 X |
EN 600079-15 II 3 G EEx nA II T.. KEMA 06 ATEX 0021 X |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
|
EN 61000-6-3 |
EN 61000-6-4:2001 |
|
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
Verification of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
|
Yes |
Yes |
|
Yes |
Yes |
|
- |
- |
|
- |
- |
Marine classification association |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
Order No. |
6GK5 101-1BH00-2AA3 |
6GK5 101-1BY00-2AA3 |
6GK5 101-1BX00-2AA3 |
Product type designation |
SCALANCE X101-1POF |
SCALANCE X101-1FL |
SCALANCE X101-1AUI |
Transmission rate |
|||
Transfer rate 1 |
- |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
- |
- |
Interfaces |
|||
Number of electrical/optical connections for network components or terminal equipment maximum |
2 |
2 |
2 |
Number of electrical connections |
|||
|
1 |
1 |
2 |
|
- |
- |
- |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
Design of electrical connection |
|||
|
RJ45 port |
RJ45 port |
RJ45 port, 15-pin Sub-D socket |
|
- |
- |
- |
|
2-pole terminal block |
2-pole terminal block |
2-pole terminal block |
|
4-pole terminal block |
4-pole terminal block |
4-pole terminal block |
Number of optical interfaces for optical waveguide |
|||
|
- |
1 |
- |
|
1 |
- |
- |
Design of optical interface for optical waveguide |
|||
|
- |
- |
|
|
SC-RJ/POF port |
- |
- |
Connectable optical power relative to 1 mW |
|||
|
-6 … -0.5 dB |
-16 … -9 dB |
- - |
|
1 dB |
-8.2 dB |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-23 dB |
-30.6 dB |
- |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
0 dB |
- |
Range at the optical interface depending on the optical fiber used |
0 … 0.05 km |
0 … 5 km |
- - |
Inputs/outputs |
|||
Operating current of signaling contacts at AC maximum |
- |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
0.1 A |
Supply voltage, current consumption, power loss |
|||
Type of voltage of supply voltage |
DC |
DC |
DC |
Supply voltage external |
24 V |
24 V |
24 V |
|
18 V |
18 V |
18 V |
|
32 V |
32 V |
32 V |
Product component fusing at power supply input |
Yes |
Yes |
Yes |
Type of fusing at input for supply voltage |
1 A / 33 V |
||
Consumed current maximum |
0.12 A |
0.12 A |
0.16 A |
Active power loss at 24 V for DC |
3 W |
3 W |
3 W |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-10 … +60 °C |
-10 … +60 °C |
-10 … +60 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
Protection class IP |
IP30 |
IP30 |
IP30 |
Design, dimensions and weight |
|||
Design |
Compact |
Compact |
Compact |
Width |
40 mm |
40 mm |
40 mm |
Height |
125 mm |
125 mm |
125 mm |
Depth |
124 mm |
124 mm |
124 mm |
Net weight |
0.55 kg |
0.55 kg |
0.56 kg |
Type of mounting |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
Product properties, functions, componentsgeneral |
|||
Cascading in cases of star structuring |
- |
- |
- |
Standards, specifications, approvals |
|||
Standard |
|||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
|
EN 600079-15 II 3 G EEx nA II T.. KEMA 06 ATEX 0021 X |
EN 600079-15 II 3 G EEx nA II T.. KEMA 06 ATEX 0021 X |
EN 600079-15 II 3 G EEx nA II T.. KEMA 06 ATEX 0021 X |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
|
EN 61000-6-3 (Class B) |
EN 61000-6-3 |
EN 61000-6-4:2001 |
|
EN 61000-6-4:2001 |
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
Verification of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
- |
- |
- |
|
- |
- |
- |
Marine classification association |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
No |