Order No. |
6GK1 561-1AA01 |
6GK1 561-1AM01 |
|
Product type designation |
CP 5611 A2 |
CP 5611 A2 MPI |
|
Transmission rate |
||
|
Transmission rate at interface 1 in accordance with PROFIBUS |
9.6 Kbit/s … 12 Mbit/s |
9.6 Kbit/s … 12 Mbit/s |
|
Interfaces |
||
|
Number of electrical connections at interface 1 in accordance with PROFIBUS |
1 |
1 |
|
Design of electrical connection |
||
|
9-pin D-sub socket (RS 485) |
9-pin D-sub socket (RS 485) |
|
PCI (32 bit 3.3 V/5 V Universal Key 33/66 MHz) |
PCI (32 bit 3.3 V/5 V Universal Key 33/66 MHz) |
|
Supply voltage, current consumption, power loss |
||
|
Type of power supply |
DC |
DC |
|
Power supply 1 from backplane bus |
5 V |
5 V |
|
Relative symmetrical tolerance at 5 V DC |
5 % |
5 % |
|
Maximum current input 1 from backplane bus with DC |
0.5 A |
0.5 A |
|
Effective power loss |
2.5 W |
2.5 W |
|
Permitted ambient conditions |
||
|
Ambient temperature |
||
|
5 … 55 °C |
5 … 40 °C |
|
-20 … +60 °C |
-20 … +60 °C |
|
-20 … +60 °C |
-20 … +60 °C |
|
Relative humidity at 25 °C without condensation during operation, maximum |
95 % |
95 % |
|
IP degree of protection |
IP00 |
IP00 |
|
Design, dimensions and weights |
||
|
Module format |
PCI |
PCI |
|
Width |
18 mm |
18 mm |
|
Height |
102 mm |
111 mm |
|
Depth |
130 mm |
129 mm |
|
Net weight |
100 g |
400 g |
|
Product properties, functions, componentsGeneral |
||
|
Number of plug-in cards of same design which can be inserted per PC station |
1 |
1 |
|
Number of modules - Note |
- |
- |
|
Performance data |
||
|
Performance dataOpen communication |
||
|
Software required for open communication by means of SEND/RECEIVE |
Yes, SOFTNET-PB DP / SOFTNET-PB DP Slave / SOFTNET-PB S7 |
Yes, SOFTNET-PB DP / SOFTNET-PB DP Slave / SOFTNET-PB S7 |
|
Number of possible connections for open communication by means of SEND/RECEIVE, maximum |
50 |
50 |
|
Performance data PROFIBUS DP |
||
|
Software required for DP master function |
Yes, SOFTNET-PB DP |
Yes, SOFTNET-PB DP |
|
Service as DP master |
||
|
Yes |
Yes |
|
No |
No |
|
No |
No |
|
Number of DP slaves operable on DP master |
64 |
64 |
|
Data volume |
||
|
14 640 bytes |
14 640 bytes |
|
14 640 bytes |
14 640 bytes |
|
244 bytes |
244 bytes |
|
244 bytes |
244 bytes |
|
244 bytes |
244 bytes |
|
Software required for DP slave function |
Yes, SOFTNET-PB DP Slave |
Yes, SOFTNET-PB DP Slave |
|
Service as DP slave |
||
|
Yes |
Yes |
|
No |
No |
|
Data volume |
||
|
122 bytes |
122 bytes |
|
122 bytes |
122 bytes |
|
Performance dataS7 communication |
||
|
Software required for S7 communication |
Yes, SOFTNET-PB S7 |
Yes, SOFTNET-PB S7 |
|
Number of possible connections for S7/PG communication, maximum |
8 |
8 |
|
Performance dataMultiprotocol operation |
||
|
Number of configurable connections per PC station |
207 |
207 |
|
Product functionsManagement, configuration, programming |
||
|
Configuration software required |
NCM PC included in scope of delivery of required software product |
NCM PC included in scope of delivery of required software product |
|
Product functionsDiagnostics |
||
|
Product function: Port diagnostics |
Yes |
Yes |
|
Standards, specifications, approvals |
||
|
Standard |
||
|
89/336/EEC |
89/336/EEC |
|
CAN/CSA C22.2 & UL 60950-1, UL 1950 |
CAN/CSA C22.2 & UL 60950-1, UL 1950 |
|
EN 61000-6-3 |
EN 61000-6-3 |
|
EN 61000-6-2 |
EN 61000-6-2 |
|
Certificate of suitability |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Accessories |
||
|
Accessories |
Optional: MPI cable |
Included in scope of delivery: MPI cable |