SITRANS F R rotary-piston meters

Nominal diameter (DN), nominal pressure (PN) and permissible flow rates q for rotary-piston meters and automatic batchmeters

Version

DN

PN

Rated flow

Permissible flow rate

With
viscosity

Min.1) in continuous operation2)

Max. in intermittent operation3)4)

Max. in
continuous operation8)

mm

(inch)

bar

(psi)

l/min

(USgpm)

mPa·s (cp)

l/min

(USgpm)

l/min

(USgpm)

l/min

(USgpm)

Rotary-piston meters for industrial use

15 5)

( )5)

25

(363)

20

(5.3)

1
< 5
800
2000
5000
100007)

1,5
1,0  
0,2
0,2
0,2
0,2

(0.26)
(0.2)
(0.05)
(0.03)
(0.03)
(0.03)

10 6)
20
20
10
4
1a€‚

(5.3)
(5.3)
(5.3)
(1.3)
(0.53)
(0.26)

10
10
10
5
2
1

(2.6)
(2.6)
(2.6)
(1.3)
(0.53)
(0.26)

25

(1)

10
16
25
40
63

(145)
(232)
(363)
(580)
(914)

100

(26.4)

0,3
0,6
1
5
800
5000
10000
20000 7)

12
6
5
3
1
1
1
1

(3.2)
(1.6)
(1.3)
(0.8)
(0.26)
(0.26)
(0.26)
(0.26)

100
100
100
100
100
80
70
50

(26)
(26)
(26)
(26)
(26)
(13)
(5.3)
(2.6)

80
80
80
80
80
60
50
30

(13)
(13)
(13)
(13)
(13)
(13)
(5.3)
(2.6)

50

(2)

6
16
25
40
63

(87)
(232)
(363)
(580)
(914)

500

(132)

0,3
0,6
1
5
800
5000
10000
20000

40
20
18
10
2
2
2
2

(11)
(5.3)
(4.8)
(2.6)
(0.53)
(0.53)
(0.53)
(0.53)

500
500
500
500
500
350
300
150

(106)
(132)
(132)
(132)
(106)
(53)
(21)
(11)

350
350
350
350
350
250
180
100

(44)
(44)
(44)
(44)
(44)
(44)
(21)
(11)

80

(3)

68)
25
40

(58)
(87)8)
(363)
(580)

1000

(264)

0,3
0,6
1
5
800
5000
10000
200007)

60
35
25
10
5
5
5
5

(16)
(9.3)
(6.6)
(2.6)
(1.3)
(1.3)
(1.3)
(1.3)

1000
1000
1000
1000
1000
700
600
300

(211)
(264)
(264)
(264)
(211)
(93)
(40)
(20)

700
700
700
700
500
350
250
150

(93)
(93)
(93)
(93)
(93)
(93)
(40)
(20)

Rotary-piston meter of acid-resistant design

25

(1)

10

(145)

100

(26.4)

0,6
1
5

10
8
4

(2.6)
(2.1)
(1.0)

100
100
100

(26)
(26)
(26)

50
50
50

(13)
(13)
(13)

Automatic batchmeter (rotary-piston meter with quantity preset register and mechanical shut-off valve)

25

(1)

10

(145)

100

(26.4)

0,3
0,6
1
5
8009)

12
6
5
3
1

(3.2)
(1.6)
(1.3)
(0.8)
(0.26)

100
100
100
100
100

(26)
(26)
(26)
(26)
(26)

50

(2)

6
10 8)

(87)
(145) 8)

500

132

0,3
0,6
1
5
8009)

40
20
18
10
2

(11)
(5.3)
(4.8)
(2.6)
(0.53)

500
500
500
500
400

(106)
(132)
(132)
(132)
(106)


1) For metal rotary-pistons: increase by a factor of 2, for PCTFE and PTFE/graphite filling rotary-pistons: increase by a factor of 3.

2) Continuous operation: over 8 hours a day.

3) For metal pistons: Reduce by a factor 0.8 to extend service life

4) Intermittent operation: up to 8 hours a day

5) Note: When using pistons made of carbon, there is higher risk of breakage in case of liquid hammers

6) When using pistons made of carbon

7) Flow rates for higher viscosities on request; we have experience with ranges up to 350000 mPa s (cp)

8) Values in brackets apply to casing made of CrNiMo steel

9) Max. permissible viscosity for exact closing of the shut-off valve and for exact dispensing; viscosities up to around 4000 mPa s (cp) possible

Note:
In order to extend the service life of the pulse sensor, rotary-piston meters with current and/or pulse output (without intermediate gear) should only be operated at max. 60 % of the permissible flow.

Piston materials

Piston material

Version

Permissible liquid temperature

Max. perm. dyn. viscosity

Order No. code

°C

°F

mPa·s (cp)

Carbon

-10 ... 300

14 ... 572

25

K

Cast iron (mat. No. GG 25)
Cast iron (mat. No. GG 25)


With slotting

-10 ... 300
-10 ... 300

14 ... 572
14 ... 572

E
B

Ni-Resist (mat. No. 0.6660)
Ni-Resist (mat. No. 0.6660)


With slotting

-10 ... 300
-10 ... 300

14 ... 572
14 ... 572

N
C

Hard rubber
Hard rubber


With slotting

-10 ... 401)
-10 ... 401)

14 ... 1041)
14 ... 1041)

50
50

G
D

PTFE/graphite filling
PTFE/graphite filling
PTFE/graphite filling
PTFE/graphite filling


With slotting

With slotting

0 ... 402)
0 ... 402)
0 ... 902)
0 ... 902)

32 ... 1042)
32 ... 1042)
32 ... 1942)
32 ... 1942)

120
120
120
120

F
L
R
M

PCTFE
PCTFE


With slotting

-10 ... +402)
-10 ... +402)

14 ... 1042)
14 ... 1042)

120
120

H
J

CrNi steel with carbon contact surface (only DN 25 (1“))
CrNi steel with PTFE contact surface (only DN 25 (1“))

Collar piston

-10 ... +200
-10 ... +40

14 ... 392
14 ... 104

> 10
> 10

S
T


1) For 120 min max. 65 °C (149 °F); for 20 min max. 90 °C (194 °F), e.g. for cleaning purposes

2) Error limit max. 1 %, at 90°C (194 °F) max. 2 %.

Other technical specifications

Materials and max. permissible liquid temperatures

Housing (also lining with acid-resistant meters) and measuring chamber

Temperature range

  • Cast iron, spheroidal graphite, cast steel, Cranium steel

-30 ... +300 °C (-22 ... +572 °F)

  • Cast iron/enamel, duroplastic measuring chamber

-20 ... +80 °C (-4 ... +176 °F)

Error limits

Error limits

Between 0.2 % and 0.5 % of the correct value (depending on the metered fluid, the measuring range and the relevant calibration regulations), except for rotary-piston meters DN 15 ( “) and acid-resistant meters with PCTFE pistons; where 1 % of the actual value applies.

Reproducibility

Within 0.05 %

Controllability

In steps from 0.01 %

Rated loss

Max. permissible 3 bar (43.5 psi), max. 0.5 bar (7.25 psi) for acid resistant meters

Transmission from wet to dry space

Gland-free, using permanent magnet coupling

Installation position (axis of meter mechanism)

  • Rotary-piston meters for industrial use

  • Acid-resistant model

Any

  • Automatic batchmeter

Vertical

  • Special designs

  • Rotary-piston meter for oil fuels

Any

  • Rotary-piston meter for liquefied gas

Meter axis vertical

Special inlet and outlet pipe sections

Not necessary

Pipe connection

Flange drilled to EN 1092-01

Filter size (mesh width)

0.8 mm (0.031 inch) for rotary-piston meters


Notes

The material combinations which can be supplied are listed in the Ordering data.
The maximum permissible liquid temperature is determined by the “weakest link” in the particular combination (the PCTFE rotary-piston or the gasket, for example, in a meter made of CrNiMo steel).

Automatic batchmeter

With this meter, the maximum permissible liquid temperature is also limited by the operation and design of the shut-off valve.

The following are permissible for valves with maintenance free

  • Gland seal: -10 ... +200 °C (14 ... 392 °F)
  • Bellows seal: -10 ... + 40 °C, max. 3 bar (14 ... 104 °F, max. 43.5 psi)

Models for higher liquid temperatures on request. The installation of cooling attachments also necessitates a corresponding increase in length of the mechanical shut-off valve.

The following restriction applies to the automatic batchmeters because of the higher flow resistance through the associated shut-off valve:

  • With the same value q, p is increased by approx. 30 %
  • With the same p, q is reduced by approx. 20 %

If the dynamic viscosity is greater than 60 mPa s (cp), constructional details of the shut-off valve cone must be changed.

Also, no filter is installed if the dynamic viscosity exceeds 800 mPa s (cp).























































Каталог оборудования
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Контрольно-измерительные приборы Pressure gauge Датчики давления Приборы измерения температуры SITRANS T Расходомеры Введение SITRANS F M электромагнитные расходомеры SITRANS F C - кориолисов массовый расходомер SITRANS F US - ультразвуковой расходомер Ультразвуковой контроллер SITRANS F X (Vortex) SITRANS F O delta p primary devices SITRANS F R rotary-piston meters DN 15 DN 25 DN 50 DN 80 Автоматические дозаторы на основе кольцевых счетчиков Блоки регистрации и управления SITRANS F RA110 electric flow registers Дополнительные модули Уровнемеры Расходомеры и счетчики Позиционеры Устройство для защиты и пуска двигателей SIMOCODE-DP Блок питания/искробезопасной развязки датчиков SITRANS I Источники питания и разделители Сигнализаторы сбоев в промышленном процессе Аппаратные ПИД-регуляторы SIPART Встраиваемые самописцы и индикаторы Коммуникации и программное обеспечение Анализаторы процесса Технологии взвешивания Датчики зрения Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика