Version |
MAG 3100 |
MAG 3100 HT (High Temperature) |
---|---|---|
Product characteristic |
Flexible product program |
Flexible product program |
Nominal size |
DN 15 … DN 2000 ( " … 78") |
DN 15 … DN 300 ( " … 12") |
Measuring principle |
Electromagnetic induction |
Electromagnetic induction |
Excitation frequency (Mains supply: 50 Hz/60 Hz) |
|
|
|
|
|
|
|
|
|
||
Process connection |
||
Flanges |
EN 1092-1, raised face 1) (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions) |
EN 1092-1, raised face (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions) |
DN 65 … 2000 (2 " … 78"): PN 6 (87 psi) |
DN 15 … 300 ( " … 12"): PN 40 (580 psi) |
|
DN 200 … 2000 (8" … 78"): PN 10 (145 psi) |
DN 65 … 300 (2 " … 12"): PN 16 (232 psi) |
|
DN 65 … 2000 (2 " … 78"): PN 16 (232 psi) |
DN 200 … 300 (8" … 12"): PN 10 (145 psi) |
|
DN 200 … 600 (8" … 24"): PN 25 (362 psi) |
DN 200 … 300 (8" … 12"): PN 25 (362 psi) |
|
DN 15 … 600 ( " … 24”): PN 40 (580 psi) |
||
DN 50 … 300 (2" … 12"): PN 63 (913 psi) |
||
DN 25 … 300 (1" … 12"): PN 100 (1450 psi) |
||
ANSI B16.5 (~BS 1560), raised face: |
ANSI B16.5 (~BS 1560), raised face: |
|
" … 24": Class 150 (20 bar (290 psi)) |
" … 12": Class 150 (20 bar (290 psi)) |
|
" … 24": Class 300 (50 bar (725 psi)) |
" … 12": Class 300 (50 bar (725 psi)) |
|
AWWA C-207, flat face 28" … 78": Class D (10 bar) |
||
AS 2129, raised face " … 48": Table E |
AS 2129, raised face " … 12": Table E |
|
AS 4087, raised face: |
||
PN 16 (DN 50 … 1200, 16 bar (232 psi)) |
||
PN 21 (DN 50 … 600, 21 bar (304 psi)) |
||
PN 35 (DN 50 … 600, 35 bar (508 psi)) |
||
JIS B 2220:2004 |
||
K10 (1" … 24") |
||
K20 (1" … 24") |
||
Other flanges and pressure ratings on request |
Other flanges and pressure ratings on request |
|
Rated operation conditions |
||
Ambient temperature
|
||
|
-40 … +100 °C (-40 … +212 °F) |
-40 … +100 °C (-40 … +212 °F) |
|
-20 … +60 °C (-4 … +140 °F) |
for up to 150 °C (302 °F) temperature of medium: -20 … +60 °C (-4 … +140 °F) |
for 150 … 180 °C (302 … 356 °F) temperature of medium: -20 … +50 °C (-4 … +122 °F) |
||
|
||
|
-20 … +60 °C (-4 … +140 °F) |
-20 … +60 °C (-4 … +140 °F) |
|
-20 … +60 °C (-4 … +140 °F) |
-20 … +60 °C (-4 … +140 °F) |
|
-10 … +60 °C (14 … 140 °F) |
-10 … +60 °C (14 … 140 °F) |
Operating pressure [abs. bar] (maximum operating pressure decreases with increasing operating temperature and with stainless steel flanges) |
|
|
|
||
|
||
|
||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
Enclosure rating |
IP67 to EN 60529/NEMA 6P/10, 1 mH2O for 30 min |
IP67 to EN 60529/NEMA 4X/6, 1 mH2O for 30 min |
Option: IP68 to EN 60529/NEMA 6P,10 mH2O cont. (not for Ex) |
Option: IP68 to EN 60529/NEMA 6P,10 mH2O cont. (not for Ex) |
|
Pressure drop at 3 m/s |
As straigth pipe |
|
Test pressure |
1.5 x PN (where applicable) |
|
Mechanical load (vibration) |
18 … 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36 |
18 … 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36 |
Sensor: 3.17 grms |
Sensor: 3.17 grms |
|
Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 grms |
Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 grms |
|
Sensor with compact MAG 6000 I/6000 I Ex mounted transmitter: 1.14 grms |
Sensor with compact MAG 6000 I/6000 I Ex mounted transmitter: 1.14 grms |
|
Temperature of medium |
|
|
|
|
|
|
|
|
|
||
|
||
|
||
EMC |
2004/108/EC |
2004/108/EC |
Design |
||
Weight |
See dimensional drawings |
|
Flange and housing material |
Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating (min. 150 m) |
Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating (min. 150 m) |
or |
or |
|
Stainless steel AISI 304/1.4301flanges and carbon steel housing, with corrosion resistant two component epoxy coating (min. 150 m) |
AISI 304/1.4301 flanges and carbon steel housing, with corrosion resistant two component epoxy coating (min. 150 m) |
|
or |
or |
|
Stainless steel AISI 316L/1.4404 flanges and housing, polished |
AISI 316L/1.4404 flanges and housing, polished |
|
Measuring pipe material |
Stainless steel AISI 304/1.4301 |
AISI 304/1.4301 |
Electrode material |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Grounding electrode material |
|
|
|
|
|
|
|
|
Terminal box (remote version only) |
|
|
|
|
|
|
|
|
Cable entries |
|
|
|
||
|
||
|
||
|
||
Certificates and approvals |
||
Calibration |
||
Standard production calibration, calibration report shipped with sensor |
Zero-point, 2 x 25 % and 2 x 90 % |
Zero-point, 2 x 25 % and 2 x 90 % |
Conforms to |
PED (All EN 1092-1 flanges conforms to PED) – 97/23/EC 3) |
PED (All EN 1092-1 flanges conforms to PED) – 97/23/EC 3) |
CRN |
CRN |
|
Material certificate EN 10204 3.1 |
On request |
On request |
Ex approvals |
Ex sensors |
Ex sensors |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
Standard sensors |
Standard sensors |
|
|
|
|
|
|
|
Drinking water approvals |
EPDM lining: |
|
|
||
|
||
|
||
|
||
|
||
|
||
Custody transfer (CT) ( DN 2000)(only together with MAG 5000/6000 CT), order as special |
Cold water pattern approval - DANAK TS 22.36.001, PTB (Denmark and Germany) |
|
Heat meter pattern approval - OIML R 75 (Denmark) |
Heat meter pattern approval - OIML R 75 (Denmark) |
|
Hot water pattern approval - PTB (Germany) |
Hot water pattern approval - PTB (Germany) |
|
Other media than water - OIML R 117 (Denmark) |
Technical specification for transmitter - please see transmitter pages.
1) PN 6-40: DN 600 type 01 (SORF); DN > 600 type 11 (WNRF); PN 63-100: type 11 (WNRF)
2) With compact transmitter MAG 5000 CT/6000 CT -20 ... +50 °C
3) For sizes larger than 600 mm (24") in PN 16 PED conformity is available as a cost-added option. The basic unit will carry the LVD (Low Voltage Directive) and EMC approval. All products sold outside of EU and EFTA are excluded from the Pressure Equipment directive, also products sold into certain market sectors are excluded. These include
a) Meters used in networks for the supply, distribution and discharge of water.
b) Meters used in pipelines for the conveyance of any fluid from offshore to onshore.
c) Meters used in the extraction of petroleum or gas, including christmas tree and manifold equipment.
d) Any meter mounted on a ship or mobile offshore platform. For further information on the PED standard and requirements see page 10/xx.
4) Only with sensors sizes DN 15 ... 300 ( " ... 12") compact.