Enclosure |
|
---|---|
Mounting |
Snap-mounting on a TH 35 DIN rail compliant with IEC 60715 or screw-mounted with additional push-in lugs |
Display |
|
"Test" button |
|
System interfaces |
|
PROFIBUS DP interface |
|
Power supply |
|
Rated control supply voltageUs (acc. to DIN EN 61131-2) |
24 V DC |
Operating range |
0.85 to 1.2 x Vs |
Power consumption (including two expansion modules connected to the basic unit) |
10 VA/7 W |
Rated insulation voltage Ui |
300 V at pollution degree 3 |
Rated impulse withstand voltage Uimp |
4 kV |
Main power outage buffering time |
200 ms |
Relay outputs |
|
Number |
Three monostable relay outputs |
Auxiliary contacts of the three relay outputs |
Isolated NO contacts with parameterizable NC behavior:
|
Specified short-circuit protection for auxiliary contacts (relay outputs) |
|
Rated uninterrupted current |
5 A, per common potential |
Rated short-circuit capacity |
|
Binary inputs |
|
Number |
Four inputs with the following properties:
|
Connections |
|
Tightening torque |
Torque: 0.8 … 1.2 Nm (7 … 10.3 lb.in) |
Conductor cross-sections |
|