|
| | |
6XV1870-8AH30Öåíà íà ñàéòå óêàçàíà ðîçíè÷íàÿ â ÅÂÐÎ áåç ó÷åòà ÍÄÑ. Äëÿ óòî÷íåíèÿ öåíû è ðàçìåðà ïðåäîñòàâëÿåìîé ñêèäêè - çâîíèòå èëè ïðèñûëàéòå çàÿâêè | Çàêàçíîé íîìåð | Âåñ | PG | Îïèñàíèå ïðîäóêòà | Öåíà | | 6XV1870-8AH30 | 0.25 | 5K1 | SIMATIC NET, IE ÑÎÅÄÈÍÈÒÅËÜÍÛÉ ÊÀÁÅËÜ M12-180/M12-180, ÏÐÅÄÑÎÁÐÀÍÍÛÉ IE FC ØËÅÉÔÎÂÛÉ ÊÀÁÅËÜ GP, Ñ 2 M12 ÐÀÇÚÅÌÀÌÈ (D-CODED), ÄËÈÍÀ 3.0 M | Ïî çàïðîñó |
Intelligent Operator Panel IOP‑2 Handheld IOP‑2 Handheld for mobile use The Intelligent Operator Panel IOP‑2 Handheld is a very user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G110D, SINAMICS G120D, SINAMICS G110M and SIMATIC ET 200pro FC‑2 distributed inverters. The IOP‑2 Handheld supports both newcomers and drive experts. Thanks to the membrane keyboard with a central sensor control field, the high-contrast color displays, the menu-based operation and the application wizards, it is easy to commission standard drives. A drive can be essentially commissioned without having to use a printed parameter list – as the parameters are displayed in plain text, and explanatory help texts and a parameter filtering function are provided. Application wizards interactively guide you when commissioning important applications such as conveyor technology, pumps, fans and compressors. There is a basic commissioning wizard for general commissioning. Up to two process values can be graphically visualized and up to four process values can be numerically visualized on the status screen/display. Process values can also be displayed in technological units. The IOP‑2 Handheld supports standard commissioning of identical drives. For this purpose, a parameter list can be copied from an inverter into the IOP‑2 Handheld and downloaded into other drive units of the same type as required. In addition to the IOP‑2, the IOP‑2 Handheld includes a housing with rechargeable batteries, a charging unit, an RS232 connecting cable, and a USB cable. The charging unit is supplied with connector adapters for Europe, the US and UK. When the batteries are fully charged, the operating time is up to 10 hours. To connect the IOP‑2 Handheld to SINAMICS G110D, SINAMICS G120D, SINAMICS G110M and SIMATIC ET 200pro FC‑2, the RS232 connecting cable with optical interface is required in addition. Updating the IOP‑2 Handheld The IOP‑2 Handheld can be updated and expanded using the integrated USB interface. Data to support future drive systems can be transferred from the PC to the IOP‑2 Handheld. Further, the USB interface allows user languages and wizards that will become available in the future to be subsequently downloaded and the firmware to be updated for the IOP‑2 Handheld 1). 1) Information on updates for the IOP‑2 Handheld is available at https://support.industry.siemens.com/cs/document/67273266 Selection and ordering data Description | Article No. |
|---|
IOP‑2 Handheld For use with SINAMICS G120 SINAMICS G120C SINAMICS G120P SINAMICS G110D SINAMICS G120D SINAMICS G110M SIMATIC ET 200pro FC‑2 Included in the scope of delivery: - IOP‑2
- Handheld housing
- Rechargeable batteries (4 × AA)
- Charging unit (international)
- RS232 connecting cable
3Â m (9.84Â ft) long, can be used in combination with SINAMICSÂ G120 SINAMICSÂ G120C SINAMICSÂ G120P - USB cable
1Â m (3.28Â ft) long
| 6SL3255-0AA00-4HA1 | RS232 connecting cable 2.5 m (8.20 ft) long, with optical interface for connecting the IOP‑2 Handheld to SINAMICS G110D SINAMICS G120D SINAMICS G110M SIMATIC ET 200pro FC‑2 | 3RK1922-2BP00 |
Technical specifications  | IOP‑2 Handheld 6SL3255-0AA00-4HA1 |
|---|
Display | High-contrast color display, a variety of display options | | 320 × 240 pixels | Operator panel | Membrane keyboard with central sensor control field | Operating languages | English, German, French, Italian, Spanish, Portuguese, Dutch, Swedish, Finnish, Russian, Czech, Polish, Turkish, Chinese Simplified | Ambient temperature |  | - During transport and storage
| -20 ... +55 °C (-4 ... +131 °F) | | 0 ... 40 °C (32 ... 104 °F) | Humidity | Relative humidity < 95 %, non-condensing | Degree of protection | IP20 | Dimensions (H × W × D) | 195.04 × 70 × 37.58 mm (7.68 × 2.76 × 1.48 in) | Weight, approx. | 0.724 kg (1.6 lb) | Compliance with standards | CE, RCM, cULus, EAC, KCC-REM-S49-SINAMICS |
Memory card SINAMICS SD memory card The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card, the drive system is immediately ready for use again. - Parameter settings can be written from the memory card to the inverter or saved from the inverter to the memory card.
- Up to 100Â parameter sets can be stored.
- The memory card supports standard commissioning without the use of the Intelligent Operator Panel IOP‑2 Handheld or the STARTER and SINAMICS Startdrive commissioning tools.
Note: The memory card is optional, but it facilitates inverter replacement. Selection and ordering data Description | Â | Article No. |
|---|
SINAMICS SD card 512 MB |  | 6SL3054-4AG00-2AA0 | Optional firmware memory cards | SINAMICS SD card 512 MB + firmware V4.7 SP3 (Multicard V4.7 SP3) |  | 6SL3054-7TB00-2BA0 | SINAMICS SD card 512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6) |  | 6SL3054-7TD00-2BA0 | SINAMICS SD card                                                                        512 MB + firmware V4.7 SP9 (Multicard V4.7 SP9) | NEW | 6SL3054-7TE00-2BA0 |
For an overview and more information on all available firmware versions, see https://support.industry.siemens.com/cs/document/67364620 PC inverter connection kit 2 (mini USB interface cable for communication with a PC)For controlling and commissioning an inverter directly from a PC via a point-to-point connection if the appropriate software (STARTER commissioning tool1), V4.3 SP3 and higher or SINAMICS Startdrive V13 and higher) has been installed. Selection and ordering data Description | Article No. |
|---|
PC inverter connection kit 2 USB cable (3 m/9.84 ft long) for - SINAMICSÂ G120C
- SINAMICSÂ G120 Control Units
- SINAMICSÂ G110M Control Units
- SINAMICSÂ G120D Control Units
| 6SL3255-0AA00-2CA0 |
1) The STARTER commissioning tool is also available on the Internet at http://www.siemens.com/starter Wall mounting kit SINAMICS G110M wall mounting kit A wall mounting kit is available if SINAMICS G110M should not be mounted on a (geared) motor. With the wall mounting kit the SINAMCS G110M frequency inverter can be mounted close to the motor in the application and can thus be used flexibly, adapted to the conditions of the application. The wall mounting kit contains a metal cable gland for connecting the motor cable (max. 5 m/16.41 ft shielded) and a fan including connecting cable for cooling the Power Module. Notes: Only one of the CU240M Control Units for motors with shaft height 71 fits on a wall mounting kit. All Power Modules from 0.37 kW to 4 kW can be mounted. The degree of protection with a wall mounting kit is IP66/UL Type 12. Compatible CU240M Control Units Control Unit | Communications via | Connection system | Control Unit for motors with shaft height 71 |
|---|
CU240M | USS, Modbus RTU | Screw-type version | 6SL3544-0LB02-1BA0 | CU240MÂ AS-i | AS-Interface | Screw-type version | 6SL3544-0LB02-1MA0 | Plug-in version | 6SL3544-0TB02-1MA0 | CU240MÂ DP | PROFIBUS | Screw-type version | 6SL3544-0LB02-1PA0 | Plug-in version | 6SL3544-0TB02-1PA0 | CU240MÂ PN | PROFINET, EtherNet/IP | Screw-type version | 6SL3544-0LB02-1FA0 | Plug-in version | 6SL3544-0TB02-1FA0 |
Selection and ordering data Description | Article No. |
|---|
Wall mounting kit | 6SL3566-1GA00-0GA0 | Spare part | Replacement fan for wall mounting kit (includes fan, connecting cable and cable gland) | 6SL3500-0TF02-0AA0 |
Dimensional drawings  SINAMICSÂ G110M wall mounting kit Installation kitsDifferent installation kits can be ordered as accessories for the Control Units with plug-in connections and Control Units with cable gland connections. These kits include covers or cable glands for protecting or connecting the 400Â VÂ 3Â AC supply, the 24Â VÂ DC supply and the mechanical motor brake. Selection and ordering data Description | Article No. |
|---|
Installation kit for Control Units with cable gland connections Includes cable glands for connecting the 400Â VÂ 3Â AC supply, the 24Â VÂ DC supply and the mechanical motor brake | 6SL3566-2VA00-0GA0 | Installation kit for Control Units with plug-in connections Includes covers for protecting the 400Â VÂ 3Â AC and 24Â VÂ DC input connectors and a cable gland for connecting the mechanical motor holding brake | 6SL3566-2LA00-0GA0 |
STARTER commissioning toolThe STARTER commissioning tool (V4.3 SP3 and higher) supports the commissioning and maintenance of SINAMICSÂ G110M inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily. Selection and ordering data Description | Article No. |
|---|
STARTER commissioning tool 1) on DVD‑ROM | 6SL3072-0AA00-0AG0 |
1) The STARTER commissioning tool is also available on the Internet at http://www.siemens.com/starter SINAMICS Startdrive commissioning toolThe SINAMICS Startdrive commissioning tool (V13 and higher) supports the commissioning and maintenance of SINAMICS G110M inverters. SINAMICS Startdrive is part of the TIA Portal engineering platform. It supports the intuitive integration of SINAMICS drives in automation. The same operator control concept, the elimination of interfaces and a high degree of user-friendliness make it possible to quickly integrate SINAMICS into an automation process and start it up with the TIA Portal. The TIA Portal with SINAMICS Startdrive offers you a totally integrated engineering platform for the complete application from the project engineering phase through to commissioning and diagnostics. Selection and ordering data Description | Article No. |
|---|
SINAMICS Startdrive commissioning tool 1) on DVD‑ROM | 6SL3072-4DA02-0XG0 |
1) The SINAMICS Startdrive commissioning tool is also available on the Internet at https://support.industry.siemens.com/cs/document/68034568 Â An overview of all available accessories (e.g. connectors and cables) can be found under the following link: http://www.siemens.com/distributeddrives-supplementaryproducts Connecting cables for the Control UnitPROFINET connecting cable Flexible plug-in cables and plug-in connectors that can be assembled in the field for transmission of data (up to 100Â Mbit/s) between Industrial Ethernet stations with IP65 degree of protection. Selection and ordering data Description | Article No. |
|---|
IE connecting cable M12‑180/M12‑180, axial outlet Pre-assembled IE FC TP trailing cable GP 2 x 2 PROFINET type C with two 4-pole M12 plugs (4-pole, D-coded), IP65/IP67 degree of protection, UL, plug/plug connector (IN/OUT) Length: |  | | 6XV1870-8AE30 | | 6XV1870-8AE50 | | 6XV1870-8AH10 | | 6XV1870-8AH15 | | 6XV1870-8AH20 | | 6XV1870-8AH30 | | 6XV1870-8AH50 | | 6XV1870-8AN10 | | 6XV1870-8AN15 | IE connecting cable M12-180/IE FC RJ45 Plug 145 axial outlet Pre-assembled IE FC TP Trailing Cable GP 2 x 2 (PROFINET Type C) with M12 plugs (D-coded) and IE FC RJ45 plug, IP65/IP67 degree of protection Length: |  | | 6XV1871-5TH20 | | 6XV1871-5TH30 | | 6XV1871-5TH50 | | 6XV1871-5TN10 | | 6XV1871-5TN15 | IE M12 Plug PRO axial outlet For assembly in the field, M12 plug-in connector (D-coded), metal enclosure, UL, fast connection method, plug connector |  | | 6GK1901-0DB20-6AA0 | | 6GK1901-0DB20-6AA8 |
PROFIBUS connecting cable Flexible plug-in cables/connectors for transmission of data (up to 12Â Mbit/s) from PROFIBUS stations. Selection and ordering data Description | Article No. |
|---|
PROFIBUS M12 plug-in cable axial outlet Pre-assembled with two 5-pole M12 plug/socket connectors, UL Length: |  | | 6XV1830-3DE30 | | 6XV1830-3DE50 | | 6XV1830-3DH10 | | 6XV1830-3DH15 | | 6XV1830-3DH20 | | 6XV1830-3DH30 | | 6XV1830-3DH50 | | 6XV1830-3DN10 | | 6XV1830-3DN15 | PROFIBUS M12 plug connector axial outlet 5-pole, B-coded, metal enclosure, 1 package = 5 units |  | | 6GK1905-0EA00 | | 6GK1905-0EB00 |
AS-Interface connecting cable Selection and ordering data Description | Article No. |
|---|
AS-Interface M12 branch To connect the AS-Interface and the UAux cable to an M12 socket, UL | Â | | 3RK1901-1NR21 | | 3RK1901-1NR22 |
Connecting cables/connectors for supplying the Control Unit with power Selection and ordering data Description | Article No. |
|---|
7/8" plug-in cable, axial outlet For 24 V switched and unswitched, pre-assembled with 2 × 7/8" at both ends (axial), 5 × 1.5 mm2, 5-pole plug/socket connectors Length: |  | | 6XV1822-5BE30 | | 6XV1822-5BE50 | | 6XV1822-5BH10 | | 6XV1822-5BH15 | | 6XV1822-5BH20 | | 6XV1822-5BH30 | | 6XV1822-5BH50 | | 6XV1822-5BN10 | | 6XV1822-5BN15 | 7/8" power cable, angled outlet, pre-assembled at one end For 24 V switched and unswitched, pre-assembled with 1 × 7/8" angled at one end, 5 × 1.5 mm2 5-pole socket connector Length: |  | | 3RK1902-3GB30 | | 3RK1902-3GB50 | | 3RK1902-3GC10 | 7/8" power cable, angled outlet For 24 V switched and unswitched, pre-assembled with 2 × 7/8" angled at both ends, 5 × 1.5 mm2, 5-pole plug/socket connectors Length: |  | | 3RK1902-3NB30 | | 3RK1902-3NB50 | | 3RK1902-3NC10 | 7/8" plug-in connector, axial outlet 5-pole, B-coded, plastic enclosure, 1 package = 5 units |  | | 6GK1905-0FA00 | - Female contact insert (IN)
| 6GK1905-0FB00 | 7/8" plug-in connector, angled outlet 5-pole, B-coded, plastic enclosure, 1Â package =Â 5Â units | Â | | 3RK1902-3BA00 | - Female contact insert (IN)
| 3RK1902-3DA00 |
Connecting cables and connectors for digital inputs and outputs Selection and ordering data Description | Article No. |
|---|
M12 plug-in cable pre-assembled at both ends, axial outlet M12 straight plug, M12 straight socket, screw mounting, 3-pole, 3 x 0.34 mm², A-coded, black PUR sheath, max. 4 A Length: |  | | 3RK1902-4PB15-3AA0 | M12 connector Y cable for distributed I/Os for dual connection of I/Os using single 5‑pole M12 cables, 200 mm (7.87 in) |  | | 6ES7194-6KA00-0XA0 |
Connecting cables and connectors for analog inputsSelection and ordering data Description | Ordering (see Solution Partner) |
|---|
M12 cable connector 8-pole plug connector |  | | Ordered from and supplied by KnorrTec | T distribution piece To connect two analog inputs 8‑pole M12 male connector to 2 × 4-pole M12 socket, angled | Ordered from and supplied by KnorrTec |
Connecting cables for Power ModulesConnecting cables pre-assembled at one end and connector sets to connect to the line supply Selection and ordering data Description | Article No. |
|---|
Connecting cable pre-assembled at one end Power supply cable, open at one end, for HAN Q4/2, angled, 4 × 4 mm2 |  | | 3RK1911-0DB13 | | 3RK1911-0DB33 | Connector set for the power supply Female contact insert HAN Q4/2, 5 socket contacts, grommet housing, angled outlet including screw connection |  | | 3RK1911-2BE50 | | 3RK1911-2BE10 | | 3RK1911-2BE30 |
Connector insert for power loop-through Selection and ordering data Description | Article No. |
|---|
Connector set for power loop-through Plug insert HAN Q4/2, 4 socket contacts, grommet housing, angled outlet including screw connection | Â | | 3RK1911-2BF50 | | 3RK1911-2BF10 |
Power bus distribution 400Â V in IP65 degree of protection Selection and ordering data Not essential (daisy chaining within device); use is optional. Description | Ordering (see Solution Partner) |
|---|
Power T clamp connector for 2.5 ... 6 mm2 With attached 7-pole connector, female contact insert, grommet housing, UL Seals for various cable cross-sections must be ordered separately | Ordered from and supplied by Harting | T clamp connector Completely pre-assembled | Ordered from and supplied by KnorrTec | T distributor box, IDC connection power cable Pre-assembled, UL, uncut power cable, 2.5 ... 6 mm2 Push-in connection: 1.5 ... 6 mm2 Seals for various cable cross-sections must be ordered separately | Ordered from and supplied by Weidmüller | Y distributor For direct connection of 400 V supply line, HAN Q4/2, conductor cross-section 1.5 ... 4 mm2 | Ordered from and supplied by Harting |
|
|