Siemens
ÑÐÅÄÑÒÂÀ ÏÐÎÌÛØËÅÍÍÎÉ ÀÂÒÎÌÀÒÈÇÀÖÈÈ
îôèöèàëüíûé ïàðòíåð Ñèìåíñ
Êàòàëîã ÑÀ01 2018
(4872) 700-366
skenergo@mail.ru

3RV2011-4AA10

Öåíà íà ñàéòå óêàçàíà ðîçíè÷íàÿ â ÅÂÐÎ áåç ó÷åòà ÍÄÑ.
Äëÿ óòî÷íåíèÿ öåíû è ðàçìåðà ïðåäîñòàâëÿåìîé ñêèäêè - çâîíèòå èëè ïðèñûëàéòå çàÿâêè

Çàêàçíîé íîìåðÂåñPGÎïèñàíèå ïðîäóêòàÖåíà
3RV2011-4AA100.3541EÀÂÒÎÌÀÒÈ×ÅÑÊÈÉ ÂÛÊËÞ×ÀÒÅËÜ ÄËß ÇÀÙÈÒÛ ÝËÅÊÒÐÎÄÂÈÃÀÒÅËß, ÒÈÏÎÐÀÇÌÅÐ S00, ÊËÀÑÑ 10, ÐÅÃÓËÈÐÎÂÊÀ ÐÀÑÖÅÏÈÒÅËß ÏÅÐÅÃÐÓÇÊÈ 11...16A, ÓÑÒÀÂÊÀ ÐÀÑÖÅÏÈÒÅËß ÒÎÊΠÊÇ ÌÃÍÎÂÅÍÍÎÃÎ ÄÅÉÑÒÂÈß 208A, ÂÈÍÒÎÂÛÅ ÊËÅÌÌÛ, ÑÒÀÍÄÀÐÒÍÀß ÊÎÌÌÓÒÀÖÈÎÍÍÀß ÑÒÎÉÊÎÑÒÜÏî çàïðîñó


Selection and ordering data

The following table lists recommendations for additional line-side components, such as fuses and circuit breakers.

Note for use in compliance with IEC standards:

3NA3 type fuses and 3RV type circuit breakers are recommended for European countries. The values in the table take into account the overload capability of the inverter.

Note for use in compliance with UL regulations:

Fuses for use in North America must be UL-certified, Class J fuses with a rated voltage of 600 V AC.

Short Circuit Current Rating (SCCR)
according to UL

Applies to industrial control panel installations according to NEC Article 409 or UL 508A

  • SINAMICS G110D: 100 kA (480 V 3 AC)

Additional information about the listed fuses and circuit breakers is available in the Catalogs LV 10, IC 10 and IC 10 AO as well as in the Industry Mall.

Individual protection

Rated power

SINAMICS G110D

IEC-compliant

UL-compliant
(according to UL category JDDZ)

 

 

Fuse

Circuit breaker

Fuse type
Rated voltage 600 V AC

 

 

Current

 

 

 

Current

kW

hp

Type
6SL3511-...

Frame size

A

Article No.

Article No.

Class

A

380 ... 500 V 3 AC

0.75

1

 . PE17-5AM0

FSA

10

3NA3803

3RV2011-1JA10

J

10

1.5

1.5 1)

 . PE21-5AM0

FSA

10

3NA3803

3RV2011-1JA10

J

25

3

4

 . PE23-0AM0

FSA

16

3NA3805

3RV2011-4AA10

J

25

4

5

 . PE24-0AM0

FSB

20

3NA3807

3RV2011-4AA10

J

30

5.5

7.5

 . PE25-5AM0

FSC

20

3NA3807

3RV2021-4BA10

J

30

7.5

10

 . PE27-5AM0

FSC

32

3NA3812

3RV2021-4EA10

J

30



1) It is not possible to make any assignment to a particular standard.

Group protection (installation on power bus)

For installations with several inverters, the inverters are normally supplied from a 400 V power bus. Further information can be found in the operating instructions on the Internet at 
http://www.siemens.com/sinamics-g110d/documentation


















  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà