Motor reactorsLine voltage 380 ... 480 V 3 AC | Motor reactor (for pulse frequencies of 2 kHz to 4 kHz) |
|---|
| 6SL3000-2BE32-1AA0 | 6SL3000-2BE32-6AA0 | 6SL3000-2BE33-2AA0 | 6SL3000-2BE33-8AA0 | 6SL3000-2BE35-0AA0 |
|---|
Rated current | A | 210 | 260 | 310 | 380 | 490 | Power loss, max. 1) | kW | 0.486 | 0.5 | 0.47 | 0.5 | 0.5 | Load connection | | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M10 | 1 ? hole for M12 | PE connection | | M8 screw | M8 screw | M8 screw | M8 screw | M8 screw | Cable length, max. between the motor reactor and motor | | | | | | | | | | | | (number of reactors in series) | | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | | m (ft) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | | m (ft) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | mm (in) | 300 (11.8) | 300 (11.8) | 300 (11.8) | 300 (11.8) | 300 (11.8) | | mm (in) | 285 (11.2) | 315 (12.4) | 285 (11.2) | 285 (11.2) | 365 (14.4) | | mm (in) | 257 (10.1) | 277 (10.9) | 257 (10.1) | 277 (10.9) | 277 (10.9) | Weight, approx. | kg (lb) | 66 (146) | 66 (146) | 66 (146) | 73 (161) | 100 (220) | Suitable for Power Module | | 6SL3310-1TE32-1AA3 6SL3315-1TE32-1AA3 | 6SL3310-1TE32-6AA3 6SL3315-1TE32-6AA3 | 6SL3310-1TE33-1AA3 6SL3315-1TE33-1AA3 | 6SL3310-1TE33-8AA3 | 6SL3310-1TE35-0AA3 6SL3315-1TE35-0AA3 | Suitable for Motor Module | | 6SL3320-1TE32-1AA3 6SL3325-1TE32-1AA3 | 6SL3320-1TE32-6AA3 6SL3325-1TE32-6AA3 | 6SL3320-1TE33-1AA3 6SL3325-1TE33-1AA3 | 6SL3320-1TE33-8AA3 | 6SL3320-1TE35-0AA3 6SL3325-1TE35-0AA3 | - Rated current of Motor Module or Power Module
| A | 210 | 260 | 310 | 380 | 490 | - Type rating of Motor Module or Power Module
| kW | 110 | 132 | 160 | 200 | 250 |
1) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions. Line voltage 380 ... 480 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AE36-1AA0 | 6SL3000-2AE38-4AA0 | 6SL3000-2AE41-0AA0 | 6SL3000-2AE41-4AA0 |
|---|
Rated current | A | 605 | 745 | 840 | 985 | 1260 | 1405 | Power loss, max. 1) | kW | 0.9 | 0.84 | 0.943 | 1.062 | 0.9 | 1.054 | Load connection | | 1 ? hole for M12 | 1 ? hole for M12 | 1 ? hole for M12 | 1 ? hole for M12 | 2 ? hole for M12 | 2 ? hole for M12 | PE connection | | M10 screw | M10 screw | M10 screw | M10 screw | M10 screw | M10 screw | Cable length, max. between the motor reactor and motor | | | | | | | | | | | | | | (number of reactors in series) | | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | | m (ft) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | | m (ft) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | | mm (in) | 410 (16.1) | 410 (16.1) | 410 (16.1) | 410 (16.1) | 460 (18.1) | 460 (18.1) | | mm (in) | 392 (15.4) | 392 (15.4) | 392 (15.4) | 392 (15.4) | 392 (15.4) | 392 (15.4) | | mm (in) | 292 (11.5) | 292 (11.5) | 292 (11.5) | 302 (11.9) | 326 (12.8) | 326 (12.8) | Weight, approx. | kg (lb) | 130 (287) | 140 (309) | 140 (309) | 146 (322) | 179 (395) | 179 (395) | Suitable for Motor Module | | 6SL3320-1TE36-1AA3 6SL3325-1TE36-1AA3 | 6SL3320-1TE37-5AA3 6SL3325-1TE37-5AA3 | 6SL3320-1TE38-4AA3 6SL3325-1TE38-4AA3 | 6SL3320-1TE41-0AA3 6SL3325-1TE41-0AA3 | 6SL3320-1TE41-2AA3 6SL3325-1TE41-2AA3 | 6SL3320-1TE41-4AA3 6SL3325-1TE41-4AA3 6SL3325-1TE41-4AS3 2) | - Rated current of the Motor Module
| A | 605 | 745 | 840 | 985 | 1260 | 1405 | - Type rating of the Motor Module
| kW | 315 | 400 | 450 | 560 | 710 | 800 |
1) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions. 2) This Motor Module has been specifically designed for loads demanding a high dynamic performance. Line voltage 500 ... 690 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AH31-0AA0 | 6SL3000-2AH31-5AA0 | 6SL3000-2AH31-8AA0 | 6SL3000-2AH32-4AA0 |
|---|
Rated current | A | 85 | 100 | 120 | 150 | 175 | 215 | Power loss, max. 1) | kW | 0.257 | 0.3 | 0.318 | 0.335 | 0.4 | 0.425 | Load connection | | Flat connector for M10 screw | Flat connector for M10 screw | Flat connector for M10 screw | Flat connector for M10 screw | Flat connector for M10 screw | Flat connector for M10 screw | PE connection | | M6 screw | M6 screw | M6 screw | M6 screw | M6 screw | M6 screw | Cable length, max. between the motor reactor and motor | | | | | | | | | | | | | | (number of reactors in series) | | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | | m (ft) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | | m (ft) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | | mm (in) | 270 (10.6) | 270 (10.6) | 270 (10.6) | 270 (10.6) | 300 (11.8) | 300 (11.8) | | mm (in) | 248 (9.76) | 248 (9.76) | 248 (9.76) | 248 (9.76) | 285 (11.2) | 285 (11.2) | | mm (in) | 200 (7.87) | 200 (7.87) | 200 (7.87) | 200 (7.87) | 212 (8.35) | 212 (8.35) | Weight, approx. | kg (lb) | 25 (55) | 25 (55) | 25.8 (56.9) | 25.8 (56.9) | 34 (75) | 34 (75) | Suitable for Motor Module | | 6SL3320-1TG28-5AA3 | 6SL3320-1TG31-0AA3 6SL3325-1TG31-0AA3 | 6SL3320-1TG31-2AA3 | 6SL3320-1TG31-5AA3 6SL3325-1TG31-5AA3 | 6SL3320-1TG31-8AA3 | 6SL3320-1TG32-2AA3 6SL3325-1TG32-2AA3 | - Rated current of the Motor Module
| A | 85 | 100 | 120 | 150 | 175 | 215 | - Type rating of the Motor Module
| kW | 75 | 90 | 110 | 132 | 160 | 200 |
1) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions. Line voltage 500 ... 690 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AH32-6AA0 | 6SL3000-2AH33-6AA0 | 6SL3000-2AH34-5AA0 | 6SL3000-2AH34-7AA0 | 6SL3000-2AH35-8AA0 | 6SL3000-2AH38-1AA0 |
|---|
Rated current | A | 260 | 330 | 410 | 465 | 575 | 735 | Power loss, max. 1) | kW | 0.44 | 0.45 | 0.545 | 0.72 | 0.8 | 0.96 | Load connection | | Flat connector for M10 screw | Flat connector for M10 screw | Flat connector for M12 screw | Flat connector for M12 screw | Flat connector for M12 screw | Flat connector for M12 screw | PE connection | | M6 screw | M6 screw | M8 screw | M8 screw | M8 screw | M8 screw | Cable length, max. between the motor reactor and motor | | | | | | | | | | | | | | (number of reactors in series) | | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | | m (ft) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | | m (ft) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | | mm (in) | 300 (11.8) | 300 (11.8) | 350 (13.8) | 410 (16.1) | 410 (16.1) | 410 (16.1) | | mm (in) | 285 (11.2) | 285 (11.2) | 330 (13.0) | 392 (15.4) | 392 (15.4) | 392 (15.4) | | mm (in) | 212 (8.35) | 212 (8.35) | 215 (8.46) | 292 (11.5) | 292 (11.5) | 279 (11.0) | Weight, approx. | kg (lb) | 40 (88) | 46 (101) | 68 (150) | 80 (176) | 80 (176) | 146 (322) | Suitable for Motor Module | | 6SL3320-1TG32-6AA3 | 6SL3320-1TG33-3AA3 6SL3325-1TG33-3AA3 | 6SL3320-1TG34-1AA3 | 6SL3320-1TG34-7AA3 6SL3325-1TG34-7AA3 | 6SL3320-1TG35-8AA3 6SL3325-1TG35-8AA3 | 6SL3320-1TG37-4AA3 6SL3325-1TG37-4AA3 | - Rated current of the Motor Module
| A | 260 | 330 | 410 | 465 | 575 | 735 | - Type rating of the Motor Module
| kW | 250 | 315 | 400 | 450 | 560 | 710 |
1) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions. Line voltage 500 ... 690 V 3 AC | Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz) |
|---|
| 6SL3000-2AH38-1AA0 | 6SL3000-2AH41-0AA0 | 6SL3000-2AH41-1AA0 | 6SL3000-2AH41-3AA0 |
|---|
Rated current | A | 810 | 910 | 1025 | 1270 | Power loss, max. 1) | kW | 1.0 | 0.97 | 1.05 | 0.95 | Load connection | | Flat connector for M12 screw | Flat connector for M12 screw | Flat connector for M12 screw | Flat connector for M12 screw | PE connection | | M8 screw | M8 screw | M8 screw | M8 screw | Cable length, max. between the motor reactor and motor | | | | | | | | | | (number of reactors in series) | | (1) | (2) | (1) | (2) | (1) | (2) | (1) | (2) | | m (ft) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | 300 (984) | 525 (1723) | | m (ft) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | 450 (1476) | 787 (2582) | Degree of protection | | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | mm (in) | 410 (16.1) | 410 (16.1) | 410 (16.1) | 460 (18.1) | | mm (in) | 392 (15.4) | 392 (15.4) | 392 (15.4) | 392 (15.4) | | mm (in) | 279 (11.0) | 279 (11.0) | 317 (12.5) | 296 (11.6) | Weight, approx. | kg (lb) | 146 (322) | 150 (331) | 163 (359) | 153 (337) | Suitable for Motor Module | | 6SL3320-1TG38-1AA3 6SL3325-1TG38-0AA3 6SL3325-1TG38-1AA3 | 6SL3320-1TG38-8AA3 | 6SL3320-1TG41-0AA3 6SL3325-1TG41-0AA3 | 6SL3320-1TG41-3AA3 6SL3325-1TG41-3AA3 | - Rated current of the Motor Module
| A | 810 | 910 | 1025 | 1270 | - Type rating of the Motor Module
| kW | 800 | 900 | 1000 | 1200 |
1) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.
|
|