The liquid-cooled Power Modules have the following interfaces as standard:
1 line supply connection
1 motor connection
1 connection for the 24 V DC electronics power supply
1 DC link connection
3 DRIVE?CLiQ sockets
1 temperature sensor input for KTY84?130, Pt1000, PTC or Pt100 (Pt1000 can be used from firmware V4.7 HF17)
1 connection for Safe Brake Adapter
1 connection for Safety Integrated
2 PE connections
2 coolant connections
The CU310-2 Control Unit can be integrated into the liquid-cooled Power Modules.
The status of the Power Modules is indicated via three LEDs.
The scope of supply of the Power Modules includes:
1 DRIVE?CLiQ cable for connection to the Control Unit
2 seals for coolant connections
1 set of warning labels in 30 languages (BG, CN, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, IE, IS, IT, JP, KR, LT, LV, MT, NL, NO, PL, PT, RO, RU, SE, SI, SK, TR)