The Basic Line Modules have the following interfaces as standard:
The status of the Basic Line Modules is indicated via three LEDs. The scope of supply of the Basic Line Modules includes:
Pre-charging circuit for the Basic Line Modules, frame size GDUnlike Basic Line Modules in frame sizes FB and GB, a Basic Line Module in frame size GD requires a separate precharging circuit. The pre-charging circuit components must be ordered separately. During startup, the pre-charging circuit ensures that the DC link capacitors of the Basic Line Module and the connected Motor Modules are pre-charged with current limiting. After pre-charging has been completed, the circuit breaker is closed and the pre-charging circuit bypassed; the Basic Line Module is then directly connected to the line supply. The pre-charging circuit comprises a pre-charging contactor and pre-charging resistors; the circuit must be protected against overcurrent using suitable protection measures. To increase the permissible DC link capacitance, the pre-charging resistors can also be connected in parallel in each phase. More information on the pre-charging circuit is to be found in the SINAMICS Low Voltage Engineering Manual. For components for the pre-charging circuit and for recommended line-side system components, see System components. |