General information | | | |
Product brand name | SIDOOR |
Product designation | Door controller |
Product version | ATE530S | ATE530S with protective coating | ATE531 with protective coating and with temperature extension |
Optional product expansion | Standard mounting rail holder 6FB1144-0AT00-3AS0 |
Manufacturer's article no. of the usable motor | 6FB1203-0AT12-7DA0 |
Manufacturer's article no. of the usable power supply unit | 6FB1112-0AT20-2TR0 |
Installation type/mounting | | | |
Installation and mounting instructions | No direct exposure to the sun |
Supply voltage | | | |
Rated value (DC) | 36 V; With MED280: At 24 V DC max. door speed of 500 mm/s, at 28.8 V DC max. door speed of 800 mm/s. With MEG251: At 24 V DC max. door speed of 500 mm/s, at 28.8 V DC max. door speed of 750 mm/s |
Power | | | |
Active power input (standby mode) | 7 W |
Digital inputs | | | |
Control inputs isolated | Yes |
Control inputs p-switching | Yes |
Fuse protection at DC end (recommendation) | Use of a circuit breaker in the supply path according to 60898-1, 8A, C-characteristic type SIEMENS: 5SY4108-7 or 5SY4108-7KK11 |
Input voltage | | | |
| 10 V; Observe polarity ! |
| 28 V; Observe polarity ! |
Input current | | | |
| 3 mA |
| 15 mA |
Digital outputs | | | |
Overload-proof | Yes |
Remark | Ensure correct polarity! CAUTION: Do not supply with external voltage! |
Output current | | | |
| 400 mA |
Relay outputs | | | |
Switching capacity of contacts | | | |
| 0.01 A |
| 0.5 A |
Mechanical data | | | |
Opening width of door, min. | 0.35 m |
Opening width of door, max. | 5 m |
Weight of door, max. | 280 kg |
Operating cycle frequency of door, max. | 180 1/h |
Kinetic energy, max. | 75 J |
Interfaces | | | |
Interfaces/bus type | PROFINET according to Conformance Class A, B, C; integrated switch for linear and ring structure |
Isolation | | | |
Overvoltage category | 2 |
Degree and class of protection | | | |
IP degree of protection | IP20 |
Standards, approvals, certificates | | | |
CE mark | Yes | No |
UL approval | No |
TUV Inspectorate approval | Yes | |
Standard for EMC | EN 61000-6-2 / EN 61000-6-4 / EN 61326-3-1 / EN 50121-3-2 / EN50121-4 / EN50121-5 |
Standard for safety | EN 60950-1 / EN 60335-1 / EN 14752 / EN ISO 13849-1 Cat. 2 PL d / IEC 62061: SIL 2 |
Ambient conditions | | | |
Ambient temperature during operation | | | |
| -25 °C |
| 50 °C | 70 °C |
| Screw control device thermally conductive onto a metallic mounting surface or standard rail mounting, otherwise the maximum operating temperature is only 40 °C | To ensure compliance with MTBF value, ensure that the ambient temperature is less than 50 °C for 90 % of operating time and screw the control unit onto a metallic mounting surface in a manner that ensures thermal conductivity or use standard rail mounting. At operating temperatures above 50 °C, the maximum output current of the 24 V DC output is a maximum of 0.1 A and the maximum number of cycles is 60/h. |
Ambient temperature during storage/transportation | | | |
| -40 °C |
| 85 °C |
Air pressure acc. to IEC 60068-2-13 | | | |
| 2 000 m |
Relative humidity | | | |
| 10 % |
| 93 % |
Mechanics/material | | | |
Service life | | | |
| 13 y |
Dimensions | | | |
Width | 320 mm |
Height | 60 mm |
Depth | 80 mm |