Transmission rate | |
Transfer rate | |
| 10 ... 100 Mbit/s |
| 0.3 ... 115.2 kbit/s |
Interfaces | |
Number of interfaces acc. to Industrial Ethernet | 1 |
Number of electrical connections | |
| 1 |
| 1 |
Type of electrical connection | |
| RJ45 port |
| Interface to the TS Module |
| 3-pole terminal block |
Supply voltage, current consumption, power loss | |
Type of voltage of the supply voltage | DC |
Supply voltage 1 from backplane bus | 5 V |
Supply voltage external | 24 V |
Supply voltage external | 19.2 ... 28.8 V |
Supply voltage external at DC Rated value | 24 V |
Supply voltage external at DC rated value | 19.2 ... 28.8 V |
Consumed current | |
| 0.25 A |
| 0.1 A |
Power loss [W] Note | 1.25 W from S7-1200 backplane without TS module. 2.4 W from 24 V DC external with TS module |
Power loss [W] | 2.4 W |
Permitted ambient conditions | |
Ambient temperature | |
| -20 ... +60 °C |
| -20 ... +70 °C |
| -40 ... -70 °C |
| -40 ... +70 °C |
Relative humidity at 25 °C without condensation during operation maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight | |
Module format | Compact module S7-1200 single width |
Width | 30 mm |
Height | 110 mm |
Depth | 75 mm |
Net weight | 0.122 kg |
Mounting type | |
| Yes |
| No |
| Yes |
Product properties, functions, components general | |
Number of units | |
| 1 |
| One CP pluggable on left side of CPU, one TS Module pluggable left side of CP. |
Performance data open communication | |
Number of possible connections for open communication | |
| like CPU |
Performance data S7 communication | |
Number of possible connections for S7 communication | |
| 2 |
| 1 |
| Configured S7-Connection for ST7-Communication |
Service | |
| Yes |
Performance data IT functions | |
Number of possible connections | |
| 1 |
Performance data telecontrol | |
Suitability for use | |
| No |
| Yes |
| No |
| Ethernet and TS Module can be operated in parallel |
Control center connection | control center with ST7 function |
| supported |
Protocol is supported | |
| Yes |
Product function data buffering if connection is aborted | Yes; 16,000 data messages |
Number of data points per station maximum | 200 |
Transmission format | |
| Yes |
| Yes |
Operating mode for scanning of data transmission | |
| Polling |
| spontaneous |
Hamming distance | |
| 4 |
Performance data Teleservice | |
Diagnostics function online diagnostics with SIMATIC STEP 7 | Yes |
Product function | |
| Yes |
| Yes |
Protocol is supported | |
| Yes |
| Yes |
Configuration software | |
| SINAUT ES V5.5 and STEP7 V13 SP1 or higher |
| Yes |
Product functions Diagnosis | |
Product function Web-based diagnostics | Yes |
Product functions Security | |
Firewall version | stateful inspection |
Suitability for operation Virtual Private Network | Yes |
Product function with VPN connection | IPSec |
Type of encryption algorithms with VPN connection | AES-256, AES-192, AES-128, 3DES-168, DES-56 |
Type of authentication procedure with VPN connection | Preshared key (PSK), X.509v3 certificates |
Type of hashing algorithms with VPN connection | MD5, SHA-1 |
Number of possible connections with VPN connection | 8 |
Product function | |
| No |
| Yes |
| Yes |
Protocol | |
| Yes |
| TCP/IP |
Key length for MSC with Virtual Private Network | 128 bit |
Number of possible connections | |
| 1 |
| 0 |
Product functions Time | |
Protocol is supported | |
| Yes |
time synchronization | |
| Yes |
| Yes |
Accessories | |
accessories | TS Module RS232 or TS Module MODEM or TS Module ISDN or TS Module GSM pluggable |