Power Modules in chassis format are controlled from the CU310-2 Control Unit via the DRIVE-CLiQ interface. Sensor Modules and Terminal Modules must be connected to the free DRIVE?CLiQ sockets of the Power Module. Parameter settings can be changed directly via the BOP20 Basic Operator Panel. The BOP20 Basic Operator Panel can also be snapped onto the CU310?2 Control Unit during operation to perform diagnostics. The CU310?2 Control Unit and other connected components are commissioned and diagnosed with the STARTER commissioning tool. A CU310-2 DP Control Unit communicates with the higher-level control system using PROFIBUS and the PROFIdrive V4 profile. A CU310?2 PN Control Unit communicates with the higher-level control system using PROFINET IO and the PROFIdrive V4 profile. The SINAMICS S120 drive system with the CU310?2 PN Control Unit then assumes the function of a PROFINET IO device and can perform the following functions:
A 24 V supply voltage must be connected to terminal X124 for the digital outputs to be used. The CU310-2 DP Control Unit requires a CompactFlash card with firmware V4.5 or higher. Connection example of CU310-2 Control Unit |