SINAMICS DC MASTER Cabinet, size CC (shown with options) The basic version of the standard cabinet system is ready to connect up and, based on the TS8 cabinet system from Rittal, offers standard components such as:
All of the auxiliary and supplementary components are supplied from the auxiliary supply (400 V 3 AC) as well as the field circuit and feeders for the DC motor fan. For straightforward operation and diagnostics, the AOP30 is mounted in the cabinet door, and the detailed documentation, including circuit manual with circuit diagram and terminal diagram, provide a well-founded technical overview of the drive cabinet. In addition to the basic version, a wide range of options allow the drive cabinet to be optimally adapted to the plant or system requirements. Note: All of the connections are established at the lower part of the cabinet. Line connectionLine connections for the armature supply (3 AC) and auxiliary power supply (400 V 3 AC) including the field supply. Main switch for the armature circuit and auxiliary power supplyFor drive cabinets from 15 up to 850 A rated DC current, the armature circuit is switched in using a manually actuated fuse load disconnector and a main contactor; from 950 A the drive cabinets are equipped with an electrically operated circuit breaker. Cable and semiconductor protectionSITOR semiconductor fuses, type 3NE are used. Line contactor for armature and fieldFor drive cabinets with a rated current from 950 A and higher, implemented as circuit breaker. The commutating reactor in the armature and field circuit is designed for the rated current of the unit. If the rated motor current is significantly lower then the rated current of the unit, then on request, a cost-optimized solution can be offered with adapted current carrying capability of the power components. DC converter including field moduleA detailed description of the DC converter can be found in the operating instructions and Catalog D 23.1. Motor connectionsIn addition to the motor connections for the field and armature, the basic version also includes the power supply for the motor fan. The setting range of the motor protection circuit breaker must be specified when placing the order. For drive cabinets for four-quadrant operation up to 850 A, the armature circuit has a DC fuse. A detailed diagram showing the electrically relevant individual components is provided in the Section, Block diagrams. Degrees of protection of drive cabinetsStandard EN 60529 addresses the protection of electrical equipment using housings, covers or equivalent, and includes:
The degrees of protection are specified by abbreviations, which comprise the code letters IP and two digits.
|
| Каталог 2018 | Каталог 2017 | Каталог 2016 | Каталог 2015 | Каталог 2014 | Каталог 2013 | Каталог 2012 | Сертификат | Контакты | Карта сайта | Поиск |