Push-through and wall mounting – side-by-side possible for both
Compact installation allows smaller cabinets to be used
Push-through mounting allows the cabinet to be cooled more easily
Can be run “out-of-the-box” without other options
Basic operator actions at a built-in BOP (Basic Operator Panel)
Frame sizes FSAA and FSAB (230 V 1 AC) 24 % smaller compared to frame size FSA within the same power range
One cable to connect SINAMICS V20 with USS and Modbus RTU at terminals
Easy integration into existing systems
Easy integration into micro automation systems
Easier commissioning through standard libraries and connection macros
Full flexibility of Modbus RTU settings widen to communicate with controller
Simple connection to a control system (SIMATIC PLC)
Possible to use dynamic braking to increase braking performance
Converters ? 7.5 kW (frame sizes FSD and FSE) have an integrated braking module. In this case, the braking resistor can be directly connected. The dynamic energy is dissipated as heat in a braking resistor with an adjustable duty cycle of between 5 % and 100 %.
SINAMICS V20 in frame sizes FSAA and FSAB, 230 V 1 AC with integrated category C1 EMC filter can be operated in residential or commercial areas in accordance with EN 61800-3. FSAA and FSAB devices are suitable for industrial applications and for industrial use in residential and commercial sectors, such as refrigerated counters, fitness equipment, ventilation systems, industrial washing machines
Easy to use
Parameter loading without power supply Parameter settings can be easily transferred from one unit to another even without power supply by using the parameter loader.
Less technical support required
Short commissioning time
The product is delivered to the customer already preset
Integrated application and connection macros to simplify I/O configuration and make the appropriate settings
Shorter training and commissioning time
Integrated and optimized application setting
Simple connection and application macros can be selected instead of configuring long complicated parameter lists
Errors caused by wrong parameter settings can be avoided
Keep Running Mode for uninterrupted operation The function provides higher productivity in production by automatic adaptation in the case of unstable line supplies.
Stable operation under difficult line supply conditions
Higher productivity through prevention of interruptions of the production line
Adaptation to application-relevant reactions through flexible definition in case of fault/alarm
Wide voltage range, advanced cooling design and coated PCBs increase robustness of the drive in difficult environments
Operation possible when the line supply voltage fluctuates
Reliable operation for line voltages: 200 V ... 240 V 1 AC (-10 %/+10 %) 1) 380 V ... 480 V 3 AC (-15%/ +10 %)
Operation at ambient temperature between -10 °C and +40 °C (max. +60 °C with derating)
Easy to save money
Energy reduction during operation and standby
ECO mode for V/f, V2/f Integrated ECO mode for V/f, V2/f automatically adapts the flux to save energy. The energy consumption can be shown in kWh, CO2 or even in the local currency.
Energy saving during low dynamic load cycles
Tells end users the actual energy that has been saved
Hibernation mode Converter and motor are only activated when used by the plant or machine
Smart hibernation saves energy
Extended lifetime of motor
Reduced pump wear at low speed
Less time to program PLC code for pump/fan applications (PLC)
DC coupling Applications that use SINAMICS V20 drives with the same power rating can share a common DC bus to reuse the regenerative energy.
Generate and save energy in applications that use coupled motors
Pairs of identical converters can optimally share resources
Reduce the need for dynamic braking and external components
Integrated energy flow monitoring
Energy consumption and savings are monitored without the need for power measurement equipment.
Intuitive values of power consumption and savings without additional investments for measurement equipment
Values can be shown as kWh, CO? or as a currency
Cost saving for low overload application for SINAMICS V20 frame size FSE
SINAMICS V20 frame size FSE features two different load cycles:
Low overload (LO): 110 % IL 2) for 60 s (cycle time: 300 s)
High overload (HO): 150 % IH 3) for 60 s (cycle time: 300 s)
With the low overload cycle, the converter can reach a higher output current and power. A smaller converter can be used.
Optimally designed for variable applications:
Low overload for applications with a low dynamic response (continuous duty)
High overload for applications with a high dynamic response (cyclic duty)
Complete motion control solutions from Siemens – SINAMICS V20 and SIMATIC
Siemens offers comprehensive solutions from a single source for general motion control applications. Through the optimized interaction between SIMATIC control and SINAMICS drive technology, as shown in our “SINAMICS Application Examples,” we can provide you with highly efficient systems.
Ready-to-run application examples, including wiring diagrams, parameter descriptions
Sample configurations for connecting SINAMICS with SIMATIC, including hardware, software and wiring examples, installation instructions for the supplied SIMATIC S7 project, drive parameterization, and HMI sample projects