Transmission rate | |
Transfer rate | 10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s |
Interfaces | |
Number of electrical connections | |
| 2 |
| 1 |
Type of electrical connection | |
| RJ45 port |
| 2-pole terminal block |
Supply voltage, current consumption, power loss | |
Type of voltage of the supply voltage | DC |
Type of voltage supply optional external supply | Yes |
Supply voltage | |
| 3.3 V |
| 12 V |
| 24 V |
| 10.5 ... 32 V |
Relative symmetrical tolerance at DC | |
| 9 % |
| 5 % |
| 8 % |
| 33 % |
Consumed current | |
| 0.85 A |
| 0.4 A |
| 0.55 A |
| 0.3 A |
Power loss [W] | 7.6 W |
Power loss [W] in switch mode maximum | 7.2 W |
Permitted ambient conditions | |
Ambient temperature | |
| 5 ... 55 °C |
| -20 ... +60 °C |
| -20 ... +60 °C |
Relative humidity at 25 °C without condensation during operation maximum | 95 % |
Protection class IP | IP00 |
Design, dimensions and weight | |
Module format | PCI Express x1 (half length) |
Width | 18 mm |
Height | 111 mm |
Depth | 167 mm |
Net weight | 124 g |
Number of plug-in cards of same design plug-in per PC station | 4 |
Number of units Note | - |
Performance data | |
Performance data open communication | |
Software for open communication by means of SEND/RECEIVE required | Yes, HARDNET-IE S7 (S7-1613) |
Number of possible connections for open communication by means of SEND/RECEIVE maximum | 120 |
Performance data S7 communication | |
Software for S7 communication required | Yes, HARDNET-IE S7 (S7-1613) |
Number of possible connections for S7/PG communication maximum | 120 |
Number of possible connections for optimized S7 communication maximum | 64 |
Performance data multi-protocol mode | |
Number of active connections with multi-protocol mode | 120 |
Number of configurable connections per PC station | 207 |
Performance data PROFINET CBA | |
Software for PROFINET CBA communication required | Yes, PN CBA OPC server |
Number of remote connection partners with PROFINET CBA | 228 |
Number of connections with PROFINET CBA total | 10 000 |
Product functions management, configuration | |
Product function MIB support | Yes |
Protocol is supported | |
| Yes |
| Yes |
| Yes |
| No |
Configuration software required | Included in the scope of delivery of the required software product |
Configuration software for PROFINET CBA required | Yes, SIMATIC iMAP |
Identification & maintenance function | |
| Yes |
| Yes |
| No |
| No |
| No |
| No |
Product functions switch | |
Product feature Switch | Yes |
Product function switch-managed | No |
Product function with IRT PROFINET IO switch | No |
Product functions Redundancy | |
Software for redundancy function required | Yes, HARDNET-IE S7-REDCONNECT for communication with SIMATIC S7 H systems |
Product functions Security | |
Firewall version | stateful inspection |
Product function with VPN connection | IPSec |
Type of encryption algorithms with VPN connection | AES-256, AES-192, AES-128, 3DES-168, DES-56 |
Type of authentication procedure with VPN connection | Preshared key (PSK), X.509v3 certificates |
Type of hashing algorithms with VPN connection | MD5, SHA-1 |
Number of possible VPN tunnels | 64 |
Number of possible connections for S7 communication | |
| 64 |
| 120 |
Number of available IP addresses with VPN connection maximum | 16 |
Product functions Time | |
Product function SICLOCK support | Yes |
Protocol is supported NTP | Yes |
Standards, specifications, approvals | |
Standard | |
| 2004/108/EC |
| CAN/CSA C22.2 & UL 60950-1, UL 1950 |
| EN 61000-6-3, EN 61000-6-4 |
| EN 61000-6-1, EN 61000-6-2 |
Certificate of suitability | |
| Yes |
| Yes |