Suitability for use | | For connecting Industrial Ethernet stations (e.g. SIMATIC ET200pro, SCALANCE X208PRO and SIMOTION) | |
Cable designation | 2YY (ST) CY 2x2x0,75/1,5-100 LI GN | 2YY (ST) CY 2x2x0,75/1,5-100 LI GN | 2YY(ST)CY6Y 2X2X0.75/1.55 LI VZN |
Wire length | 1 m | 10 m | 1 m |
Electrical data | | | |
Damping ratio per length | | | |
| 63 dB/km | 63 dB/km | 95 dB/km |
| 213 dB/km | 213 dB/km | 320 dB/km |
Impedance | | | |
| 100 ? | 100 ? | 100 ? |
Relative symmetrical tolerance | | | |
| 5 % | 5 % | 5 % |
Near-end crosstalk per length | | | |
| 500 dB/km | 500 dB/km | 353 dB/km |
Transfer impedance per length at 10 MHz | 20 m?/m | 20 m?/m | 80 m?/m |
Loop resistance per length maximum | 120 m?/m | 120 m?/m | 120 m?/m |
Operating voltage | | | |
| 80 V | 80 V | 80 V |
NVP value in percent | 66 % | 66 % | 63 % |
Mechanical data | | | |
Number of electrical cores | 4 | 4 | 4 |
Design of the shield | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Type of electrical connection FastConnect | | | Yes |
Core diameter | | | |
| 0.75 mm | 0.75 mm | 0.75 mm |
Outer diameter | | | |
| 0.75 mm | 0.75 mm | 0.75 mm |
| 1.5 mm | 1.5 mm | 1.56 mm |
| 3.9 mm | 3.9 mm | 4 mm |
| 6.5 mm | 6.5 mm | 6.5 mm |
Symmetrical tolerance of the outer diameter of cable sheath | 0.2 mm | 0.2 mm | 0.2 mm |
Material | | | |
| PE | PE | PE |
| PVC | PVC | PVC |
| PVC | PVC | PVC/FEP; FEP transparent |
Color | | | |
| white/yellow/blue/orange | white/yellow/blue/orange | white/yellow/blue/orange |
| green | green | green |
Bending radius | | | |
| 32.5 mm | 32.5 mm | 26 mm |
| 49 mm | 49 mm | 52 mm |
| 100 mm | 100 mm | 100 mm |
Number of bending cycles | 3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 100 mm, a speed of 4 m/s and an acceleration of 4 m/s? | 3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 100 mm, a speed of 4 m/s and an acceleration of 4 m/s? | 1 000 000; Acceleration 4 m/s? |
Number of torsion cycles with torsion by ± 180° on 1 m cable length | | | 1 000 000 |
Tensile load maximum | 150 N | 150 N | 150 N |
Weight per length | 68 kg/km | 68 kg/km | 72 kg/km |
Permitted ambient conditions | | | |
Ambient temperature | | | |
| -25 ... +75 °C | -25 ... +75 °C | -40 ... +80 °C |
| -25 ... +75 °C | -25 ... +75 °C | -40 ... +80 °C |
| -25 ... +75 °C | -25 ... +75 °C | -40 ... +80 °C |
| -10 ... +60 °C | -10 ... +60 °C | -40 ... +80 °C |
| Electrical properties measured at 20 °C, tests according to DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN VDE 0472 | Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Burning behavior | flame resistant according to UL 1685 (CSA FT 4) | flame resistant according to UL 1685 (CSA FT 4) | flame resistant according to IEC 60332-1-2 |
Chemical resistance | | | |
| conditional resistance | conditional resistance | oil resistant according to IEC 60811-404 (7x24 h / 90°C) |
| Conditional resistance | Conditional resistance | Conditional resistance |
| | conditional resistance | resistant |
Radiological resistance to UV radiation | resistant | resistant | resistant |
Protection class IP | IP65, IP67 | | IP65/67/69 |
Product properties, functions, components general | | | |
Product feature | | | |
| No | No | No |
| Yes | Yes | Yes |
Standards, specifications, approvals | | | |
UL/ETL listing 300 V Rating | Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES | Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES | No |
UL/ETL style 600 V Rating | Yes | Yes | No |
Certificate of suitability | | | |
| | | Yes |
| Yes | Yes | Yes |
Standard for structured cabling | Cat5e | Cat5e | Cat5e |
Marine classification association | | | |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |