General information | | | |
Product type designation | SIMATIC HMI KP8 PN | SIMATIC HMI KP8F PN | SIMATIC HMI KP32F PN |
Control elements | | | |
With parameterizable keys | Yes | Yes | Yes |
Keyboard fonts | | | |
| | | |
| Yes | Yes | Yes |
| | | |
| 8 | 8 | 32 |
| | | |
| 8 | 8 | 32 |
Expansions for operator control of the process | | | |
| 8; Adjustable brightness | 8; Adjustable brightness | 8; Adjustable brightness |
| 5; Red, green, blue, yellow, white | 5; Red, green, blue, yellow, white | 5; Red, green, blue, yellow, white |
| 8 | 8 | 32 |
Installation type/mounting | | | |
Mounting type | Mounting clip | Mounting clip | Mounting clip |
Mounting position | vertical | vertical | vertical |
Rack mounting | No | No | No |
Front mounting | Yes; Compatible with extension unit dimensions | Yes; Compatible with extension unit dimensions | Yes |
Rail mounting | No | No | No |
Wall mounting/direct mounting | No | No | No |
Mounting in portrait format possible | Yes | Yes | Yes |
Mounting in landscape format possible | Yes | Yes | Yes |
maximum permissible angle of inclination without external ventilation | 30°; To the front/rear | 30°; To the front/rear | 30°; To the front/rear |
Number of slots for command devices and signaling units | 0 | 0 | 0 |
Supply voltage | | | |
Type of supply voltage | DC | DC | DC |
Rated value (DC) | 24 V; 24 V can be looped through connector, interrupted when pulled | 24 V; 24 V can be looped through connector, interrupted when pulled | 24 V; 24 V looped through at connector, no interruption on pulling |
permissible range, lower limit (DC) | 20.4 V | 20.4 V | 20.4 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V |
Type of output | | | |
LED colors | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Digital inputs | | | |
Number of digital inputs | 8; Total inputs and outputs max. 8 and 1x SIL 2 or 2x SIL 3 | 8; Total inputs and outputs max. 8 and 1x SIL 2 or 2x SIL 3 | 32; Total inputs and outputs max. 32 and 2x SIL 2 or 4x SIL 3 |
Input voltage | | | |
| 24 V | 24 V | 24 V |
Digital outputs | | | |
Number of digital outputs | 8; Max. 8 inputs and outputs (total) | 8; Max. 8 inputs and outputs (total) | 16; Max. 32 inputs and outputs (total) |
Short-circuit protection | Yes | Yes | Yes |
Switching capacity of the outputs | | | |
| 100 mA | 100 mA | 100 mA |
Output voltage | | | |
| 24 V; Non-isolated | 24 V; Non-isolated | 24 V; Non-isolated |
Total current of the outputs | | | |
| 100 mA | 100 mA | 100 mA |
| 800 mA | 800 mA | 800 mA |
Interfaces | | | |
Number of industrial Ethernet interfaces | 2; For the construction of lines and rings without external switch | 2; For the construction of lines and rings without external switch | 2; For the construction of lines and rings without external switch |
Number of PROFINET interfaces | 2; Incl. switch | 2; Incl. switch | 2; Incl. switch |
Industrial Ethernet | | | |
| 2; Per port | 2; Per port | 2; Per port |
| 2; Per port | 2; Per port | 2; Per port |
Protocols | | | |
PROFINET | Yes; also 3rd party PLC | Yes; also 3rd party PLC | Yes; incl. shared device, 3rd party PLC |
PROFINET CBA | No | No | No |
IRT | Yes | Yes | Yes |
MRP | Yes | Yes | Yes |
PROFIsafe | No | Yes; 1x SIL 2 (two-channel) or 2x SIL 3 (single-channel) emergency stop sensor | Yes; 2x SIL 2 (two-channel) or 4x SIL 3 (single channel) emergency stop sensor |
PROFIBUS | No | No | No |
Test commissioning functions | | | |
Illuminant test | Yes; During switch on | Yes; During switch on | Yes; During switch on |
Key and signal lamp test | Yes; Automatically when switching on | Yes; Automatically when switching on | Yes; Automatically when switching on |
EMC | | | |
Emission of radio interference acc. to EN 55 011 | | | |
| Yes; Group 1, measured at a distance of 10 m | Yes; Group 1, measured at a distance of 10 m | Yes; Group 1, measured at a distance of 10 m |
| No | No | No |
Degree and class of protection | | | |
IP (at the front) | IP65 | IP65 | IP65 |
Enclosure Type 4 at the front | No | No | No |
Enclosure Type 4x at the front | Yes; Incl. NEMA12 | Yes; Incl. NEMA12 | Yes; Incl. NEMA12 |
IP (rear) | IP20 | IP20 | IP20 |
Standards, approvals, certificates | | | |
CE mark | Yes | Yes | Yes |
cULus | Yes | Yes | Yes |
RCM (formerly C-TICK) | Yes | Yes | Yes |
KC approval | Yes | Yes | Yes |
Suitable for safety functions | Yes | Yes | Yes |
Marine approval | | | |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
Use in hazardous areas | | | |
| Yes | Yes | No; On request |
| Yes | Yes | No; On request |
| No | No | No |
| Yes | Yes | No; On request |
| Yes | Yes | No; On request |
Ambient conditions | | | |
Ambient temperature during operation | | | |
| 0 °C | 0 °C | 0 °C |
| 55 °C | 55 °C | 55 °C |
| | | |
| 0 °C | 0 °C | 0 °C |
| 55 °C | 55 °C | 55 °C |
| | | |
| 0 °C | 0 °C | 0 °C |
| 45 °C | 45 °C | 45 °C |
| | | |
| 0 °C | 0 °C | 0 °C |
| 45 °C | 45 °C | 45 °C |
| | | |
| 0 °C | 0 °C | 0 °C |
| 45 °C | 45 °C | 45 °C |
Ambient temperature during storage/transportation | | | |
| -20 °C | -20 °C | -20 °C |
| 60 °C | 60 °C | 60 °C |
Relative humidity | | | |
| 95 %; no condensation | 95 %; no condensation | 95 %; no condensation |
Configuration | | | |
Configuration software | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Functionality under WinCC (TIA Portal) | | | |
Process coupling | | | |
| Yes; with ET 200pro CPU and ET 200S CPU | Yes; with ET 200pro CPU and ET 200S CPU | Yes; with ET 200pro CPU and ET 200S CPU |
| Yes | Yes | Yes |
| No | No | No |
| Yes; with F-CPU: STEP 7 V11 SP1 (or higher) and Safety V11 (or higher) or SIMATIC STEP 7 Basic V11 (or higher) | Yes; with F-CPU: STEP 7 V11 SP1 (or higher) and Safety V11 (or higher) or SIMATIC STEP 7 Basic V11 (or higher) | Yes; with F-CPU: STEP 7 V11 SP1 or higher and Safety V11 (or higher), without F-CPU STEP 7 or SIMATIC STEP 7 Basic V11 (or higher) |
| No | No | No |
| Yes | Yes | Yes |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
Mechanics/material | | | |
Enclosure material (front) | | | |
| Yes | Yes | No |
| No | No | Yes |
Service life | | | |
| 1 500 000 | 1 500 000 | 1 500 000 |
| 100 % | 100 % | 100 % |
Dimensions | | | |
Width of the housing front | 98 mm | 98 mm | 295 mm |
Height of housing front | 155 mm | 155 mm | 155 mm |
Mounting cutout, width | 68 mm; Max. thickness of mounting plate 2 - 6 mm | 68 mm; Max. thickness of mounting plate 2 - 6 mm | 277 mm; Max. thickness of mounting plate 2 - 6 mm |
Mounting cutout, height | 129 mm | 129 mm | 137 mm |
Overall depth | 49 mm; Incl. angled SIMATIC Ethernet connector | 49 mm; Incl. angled SIMATIC Ethernet connector | 69 mm; Incl. angled SIMATIC Ethernet connector |
Weights | | | |
Weight without packaging | 280 g | 280 g | 1 220 g |