Meter | |
Accuracy | ± 0.8 % ± 2.5 mm/s |
± 0.4 % ± 2.5 mm/s |
NMI (class 2.5) |
Low flow cut-off (default) | 1.0 % |
Media conductivity | Clean water > 20 µs/cm |
Temperature | |
Ambient | -20 … +60 °C (-4 … +140 °F) |
Media | 0 … 70 °C (32 … 158 °F) |
Storage | -40 … +70 °C (-40 … +158 °F) |
Enclosure rating | |
Remote sensor | IP68 to EN 60529/NEMA 6P, 10 mH2O cont. |
Compact version | IP68 to EN 60529/NEMA 6P, 3 mH2O for six months |
Approvals | |
Drinking water approvals | - ANSI/NSF 611) (cold water) USA
|
- WRAS (BS 6920 cold water) UK
|
Custody transfer approval | NMI M 10 Australia (DN 50 ... DN 1200) |
Sensor material | Carbon steel ASTM A 105, with corrosion resistant two-component epoxy coating (150 ?m/300 ?m) Corrosivity category C4M, according to ISO 12944 |
Conformity | IEC/EN 61326 |
Flanges | |
EN 1092-1 (DIN 2501) PN 10 drilled pattern | DN 50 … 600 (2" ... 24") (max. pressure 7 bar (101.5 psi)) |
ANSI 16.5 Class 150 drilled pattern | 2" … 24" (max. pressure 7 bar (101.5 psi)) |
AS 2091-1 Table D drilled pattern | DN 50 ... 600 (2" ... 24") (max. pressure 7 bar (101.5 psi)) |
AS 2129 Table E | DN 25, DN 40, DN 125 (1", 1?", 5") |
AS 4087 PN 16 | DN 50 ... DN 1200 (2" ... 48") |
Excitation frequency | |
| DN 50 … 600 (2” … 24”): 1/15 Hz |
DN 700 … 1200 (28" … 48"): 1/60 Hz |
| DN 50 … 600 (2” … 24”): 3.125 Hz |
DN 700 … 1200 (28" … 48"):1.5625 Hz |
Liner | Ebonite |
Electrodes | Stainless steel AISI 316Ti/1.4571 |