Design Attributes | |
Display size and Type | 5.7" diagonal, color Diagonal, Digital Colour LCD (TFT) with Touch Screen Industrial grade with brightness adjustment and wide viewing angle |
Resolution | QVGA (320 x 240 pixels) |
Screen Saver | Set in minutes from 1 … 720, can be set to dim the screen or to switch off. Automatic wake-up facility in the case of an alarm |
Brightness adjustment | Adjustable between 10 and 100 %, default set to 80 % brightness |
Backlight life time | 50 000 hours to half brightness when used at 100 %. Maximum luminosity 450 cd/m? |
Touch Screen life | 1 000 000 touches |
Display Update Rate | Display values updated every second |
Status Display | A status bar, at the top of the recorder’s screen, displays the real-time icons of the recorder status, such as recording time left and alarm active. |
Communications | Ethernet 10/100 base - T with RJ45 connector supporting Modbus/TCP, FTP, Internet, DHCP or fixed IP address. |
Mathematics | Basic maths include Add, Subtract, Multiply, Divide, Modulo and power. Full Maths (option) support up to 100 character free form math expression for each pen. Like SINE, COS, TAN, Log, Parenthesis (eg. A1 + A2), comm variables, free memory, and access to any data item variable (A1, P1, D1 etc.) |
Front USB Port | Front USB host port for data and setup transfers. External devices keyboard or mouse, Barcode reader, or external mass storage device. (USB 2.0 compliant) |
Standard Screens | Fully programmable display values in engineering units. Time & date stamp on every division. Sets of Standard screens are available to display data on a chart, digital reading, bargraphs or numerous combinations thereof. Screen properties can be modified on the recorder and customised to suit. Digital values displayed include: - Alarms on bars
- Engineering units
- Pen name
- Tag, time and date
- 20 character description
- Totalised values
|
Data Storage | |
- Local Mass Storage Options
| - USB memory key - must be formatted
- USB hard drive - up to 120 GByte
|
| Non-volatile, 1 GByte (9 230 million acquisition values) and 2 GByte ( up to 650 million points) |
| Stored internally on non-volatile memory |
| Data saving by inserting USB memory stick |
| Related to log rate, number of pens, totals and alarms. Each pen is capable of its own independent storage rate (100 ms … 60 h) |
| Binary encoded format |
| Internal memory has FIFO (First In First Out) capability where the newest data over-writes the oldest data |
Power Requirements | |
| 100 V AC … 250 V AC (auto select) |
| 50/60 Hz |
| < 40 W |
- 24 V optional instrument power
| 12 ... 30 V DC / 12 ... 20 V AC Power Consumption: < 40 W |
Battery | Battery backed up for clock, replaceable lithium battery Type 6032, 3.0 V – 10 years life (Recorder powered), 4 years life, typical (Recorder unpowered). |
Password Protection | Multiple Administrator control of password setup and management with four levels of password protection for – Engineer, Supervisor, Technician, and Operator. Up to 50 different users are available. Password protection restricts user entry to the recorder set up and specific screens. |
| Highest access to all levels, Supervisor, Technician and Operator |
| 2nd highest level including Technician and Operator access |
| 3rd level including Operator access |
| 4th and lowest level of access |
Languages | - English UK & US
- French
- German
- Italian
- Spanish
- Brazilian
- Polish
- Hungarian
- Slovakian
- Czech
- Turkish
- Romanian
- Russian
- Greek
- Portuguese
- Bulgarian
- Chinese
- Japanese
- Korean
|
Temperature Units | °C, °F, K |
Recorder Identification | Status bar: Alternately displays Recorder ID and Recorder Screen Name, Displays Time and Date |
Clock | |
| ± 20 ppm (± 1 minute/month) at 25 °C Summer/Winter manual or automatic time adjustment or via communications. SNTP Client and/or Server included for synchronising over Ethernet |
Alarm Set Points | 6 per pen integral "soft" alarm set points easily set by user to announce selected out of limit conditions; user can select if an alarm triggers a change in the chart background colour |
| Alarm triggers can be set for Hi, Lo, Deviation. Latched alarms require acknowledgement from the operator |
| 1 s … 24 h |
| ± 100 % of pen scale An alarm can change the log rate on the affected pen |
Data Replay Mode | Data replay facility on chart displays at normal, fast or slow speeds with zoom and cursor. Jump facility from the alarm history list directly to the occurance on the chart |
Display Chart Speeds | |
| - 1 mm/h
- 5 mm/h
- 10 mm/h
- 20 mm/h
- 30 mm/h
- 60 mm/h
- 120 mm/h
- 600 mm/h
- 1200 mm/h
- 6000 mm/h
Combinations of rates can be mixed and chart speeds can be set independently for each chart. Display speeds are independent of logging rate |
Messages Screen | The message screen displays system information and records any setup activity that has been changed. It also provides warning and error message updates, lists alarm activity and will display user defined marks on a chart |
CE Conformity (CE Mark) | This product conforms with the protection requirements of the following European Council Directives: 2014/35/EC, the Low Voltage Directive, and 2014/30/EC, the EMC Directive. Conformity of this product with any other "CE Mark" Directive(s) shall not be assumed. |
Immunity Product Classification | Complies with EN 61326?1:2013 Class I: Cord Connected, Panel Mounted Industrial Control Equipment with protective earthing (grounding), (EN 61010?1:2010) |
Enclosure Rating | Front panel designed to NEMA 3/IP54 (Optional NEMA 4X/IP66) |
Installation Requirements | Category II: Overvoltage (EN 61010?1:2010) Pollution Degree 2 |
EMC Standards | Emissions - EN 61326?1:2013 Class A Immunity - EN 61326?1:2013 Industrial Levels |
Safety | Complies with EN 61010-1: 2010 Panel Mounted Equipment, Terminals must be enclosed within the panel |
Analog Inputs | |
Number of Inputs | 3, 6, 9 or 12 input channels |
Input Types | mV, V, mA with external shunt (provided as standard), Thermocouple, RTD and ohms |
Minimum Input Span | Range is fully configurable with span limitation of the operating range selected with 4 % under range to 4 % over-range capability (50 V Range 2 %) |
Burnout (T/C) | Active (High or Low), Passive and Health watch/maintenance (option) |
Cold Junction Compensation | Internal compensation with the ability to manually adjust values, External Input for compensation, External CJC value specified |
Input Resolution | 0.0015 % (16 Bit ADC) |
Input Impedance | |
| 10 ?, use ± 0.1 % external resistor, Volts > 1 M?, all other > 10 M? |
Source Impedance | |
| 100 ? per lead maximum (a single point cal on Slot A will improve accuracy for a lead resistance above 10 ?) |
Square Root Extraction | Available as standard on Volts and mA input types |
Sensor Compensation | Single point and Dual point for every input type |
Input Sampling Rate | Recorder has 2 available slots with up to 6 analog inputs each; first slot fixed |
- Analog Input card (standard)
| 200 ms (5 Hz), 500 ms (2 Hz) |
- Analog Input expansion card
(option)
| 100 ms (10 Hz), 200 ms (5 Hz), 500 ms (2 Hz) |
Linear Scales | - Normal and Scientific notation
- Decimal Point automatic or programmable
- Engineering units, user definable (10 characters)
|
Logarithmic Scales | |
- Logarithmic Decade limits
| ?38 min … +38 max, (recommend up to 20 decades on one screen to ensure clarity) |
Input Isolation | 300 V AC channel-to-channel, channel-to-ground (Resistance thermometers are not isolated for initial card, expansion card option RTs are isolated) |
Noise Rejection | At 50/60Hz ± 2 % |
- Analog Input card (standard)
| |
| 2 Hz = ?120 dB, 5 Hz = ?120 dB |
| 2 Hz = ?80 dB, 5 Hz = ?25 dB |
- Analog Input expansion card
(option)
| |
| 2 Hz = ?120 dB, 5 Hz = ?120 dB, 10 Hz = ?120 dB |
| 2 Hz = ?85 dB, 5 Hz = ?80 dB, 10 Hz = ?48 dB |
Input Range Performance and Accuracy | For Analog Input standard and expansion cards |
Input Actuation (Linear) | Range |
| ?1000 … +1000 |
| ?50 … +50 |
| 4 … 20, 0 … 20 |
| 0 … 200 |
| 0 … 500 |
| 0 … 1000 |
| 0 … 4000 |
Thermocouples | Temperatur range |
| 260 ... 538 °C (500 ... 1000 °F) 538 ... 1816 °C (1000 ... 3300 °F) |
| ?270 ... ?200 °C (?454 ... ?328 °F) ?200 ... ?70 °C (?328 ... ?94 °F) ?70 ... +1000 °C (?94 ... +1832 °F) |
| ?210 ... 0 °C (?346 ... +32 °F) 0 ... 1200 °C (32 ... 2192 °F) |
| ?270 ... ?70 °C (?454 ... ?94 °F) ?70 ... +1372 °C (?94 ... +2502 °F) |
| ?50 ... +260 °C (?58 ... +500 °F) 260 ... 650 °C (500 ... 1202 °F) 650 ... 1768 °C (1202 ... 3214 °F) |
| ?50 ... +260 °C (?58 ... +500 °F) 260 ... 1000 °C (500 ... 1832 °F) 1000 ... 1768 °C (1832 ... 3214 °F) |
| ?270 ... ?210 °C (?454 ... ?346 °F) ?210 ... +400 °C (?346 ... +752 °F) |
| ?200 ... 0 °C (?328 ... +32 °F) 0 ... 900 °C (32 ... 1652 °F) |
| 0 ... 100 °C (32 ... 212 °F) 100 ... 316 °C (212 ... 600 °F) 316 ... 830 °C (600 ... 1526 °F) 830 ... 1515 °C (1526 ... 2759 °F) 1515 ... 2315 °C (2759 ... 4119 °F) |
| 0 ... 180 °C (32 ... 356 °F) 180 ... 1220 °C (356 ... 2228 °F) 1220 ... 2315 °C (2228 ... 4199 °F) |
| ?50 ... +370 °C (?58 ... +698 °F) 370 ... 1410 °C (698 ... 2570 °F) |
| ?200 ... +100 °C (-328 ... +212 °F) 100 ... 1300 °C (212 ... 2372 °F) |
| ?50 ... +600 °C (?58 ... +1112 °F) |
| 0 ... 1390 °C (32 ... 2534 °F) |
| 0 ... 180 °C (32 ... 356 °F) 180 ... 1840 °C (356 ... 3344 °F) 1840 ... 2490 °C (3344 ... 4515 °F) |
Resistance thermometers | Temperatur range |
| ?200 ... +850 °C (?328 ... +1562 °F) |
| ?200 ... +850 °C (?328 ... +1562 °F) |
| ?200 ... +850 °C (?328 ... +1562 °F) |
| ?200 ... +850 °C (?328 ... +1562 °F) |
| ?60 ... +180 °C (?76 ... +356 °F) |
| ?80 ... +260 °C (?112 ... +500 °F) |
Logging | |
Logging Method | Sample, Average, Min/Max - can be set independently per pen |
Logging Types | Continuous, Fuzzy |
Logging Rate | From 100 ms … 60 h per Pen |
Fuzzy Logging | A secure data storage technique which delivers data compression ratio of 100:1 or more; self teaching, storing the data at a variable rate to match the process |
Mechanical Design | |
Enclosure/Bezel | Zinc plated steel case with high impact resistant polycarbonate bezel; scratch resistant lens (Polyethylene Terephthalate). NEMA 3/IP54 protection rating standard. Optional NEMA 4X/IP66 (Front face only) |
| Front panel designed to NEMA 3/IP54 (Optional NEMA 4X/IP66) |
| Bezel: Grey |
Mounting Panel | Unlimited mounting angle For the best view of the display the viewing angle should not exceed: - 45° from the left or right,
- 10° looking down and
- 30° looking up at the recorder display.
Mounting adjustable for panel thickness of 2 mm … 20 mm. Adapter kits available for covering existing panel cutouts. |
Dimensions (W x H x D) in mm | 144 x 144 x 200 (5.67 x 5.67 x 7.87") Additional 80 mm (3.15") clearance recommended for a straight type power cable and signal connectors |
Cutout (W x H) in mm | 138 x 138 mm (5.43 x 5.43") |
Weight | Max. 2.4 kg (5.3lb) |
Wiring Connections | IEC Power Plug. Removable terminal strip for input and alarm connections |
Environmental and Operating Conditions | |
Ambient Temperature | 0 °C … 50 °C (32 °F ... 122 °F) |
Relative Humidity (%RH) | 10 ... 90 |
Vibration | |
| 0 ... 70 |
| 0.1 |
Mechanical Shock | |
| 1 |
| 30 |
Mounting Position from Vertical | |
| 40° |
| 65° |
| 65° |
Power Requirements | |
| 100 … 250 |
| 20 … 25 |
| 20 … 30 |
| 47 … 63 |
Power Consumption | AC: < 40 W (max), DC: <40 W (max), typical 20 W |
Warm Up | 30 minutes minimum |
Options | |
Alarm Outputs | Programmable alarm set points (6 per pen) can be configured to activate up to 8 outputs |
| 200 ms for all alarms |
| - 4 or 8 relay contacts SPDT,
3 A 240 V AC, 3 A 24 V AC/DC, 0.2 A 240 V DC (non-inductive, internally suppressed) - 8 I/O - SPNO 1 A 24 V DC
(non-inductive, internally suppressed)
|
| Fully programmable internal alarm levels. Assignable to any relay output |
Digital Input/Output | |
| All channels may be selected freely as either digital inputs or outputs. The Digital I/O card also has 4 channels that can be set as pulse inputs (channels 1 … 4). The operating frequency for pulse inputs on the Digital I/O card is 1kHz max. |
| Voltage free, isolated |
| 4 relay outputs, all four channels are relay outputs only |
| 2 outputs can be configured for use as digital inputs: A digital input is provided by a volt free contact between the normally open (NO) and the common (C) terminals of an output relay. If the 2 Digital inputs are used only 6 relay outputs are available. Closed < 500 ?, Open > 300 k? |
E-mail | Setup email accounts to send the following: When an Alarm is triggered or an Email can be sent as a part of an Event occurring, such as: Alarms - In/Out/Ack, Totaliser – Start, Stop or Reset, Digital Inputs – On, Off or State change, TC Burnout – on a specific Analog Input channel, Scheduled Events – Once, Interval, Specific days, Month End |
Events | User defined process events are recorded and can be set to cause particular recorder actions. Events can consist of recording start/stop, digital inputs, alarms, totalising actions, timers, barcode, etc. Once an event has been caused it can produce a definable set of effects on the recorder which can include, mark on chart, relay outputs, recording control, acknowledge alarm, trigger an Event, set/clear Relay, Screen change, E-mail a message and Reset max/mins. Each event marker can be recorded for analysis using the SIREC D application software. |
Health Watch/Maintenance Capability | The recorder keeps track of important "life actions" for improved diagnostics and preventative maintenance notification. Including - Powered On
- Last powered On
- Time On since power up
- Total On time
- Total Off time
- Longest Off time
- Lithium cell life
- Backlight life left at 100 % brightness
- Hi/Lo CJC value (Hi & Lo temps),
- Analog In last factory/user calibration
- Relay operations
- Last configuration change
|
Transmitter Power | 130 mA at 24 V DC ± 3 V DC |
Extended Security System (ESS) | Provides full support for 21 CFR Part 11. Includes features for entry of unique User ID’s and associated passwords: - Timeout on inactivity (1 … 10 min)
- Password expiration (1 … 365 days)
- Up to 50 users
- Password re-entry lock out for incorrect entry of password more than 3 times, no re-use of passwords (programmable 4 … 12 times)
- Traceability by user name
|
Totaliser/Sterilisation | One totaliser per input. Totaliser value must be assigned to a pen for display and storage. Multiple totalisations (Maths option) are possible with the use of extra pens (option). Reset may be manual or programmed. Totalisation values are 10 digits plus exponent. Each pen can be totalised according to the Fo or Po sterilisation* function at 121.11 °C (250 °F). The Standard Reference Temperature and Thermal Resistance (Z Value) are fully adjustable values of X, Y, W and V. Start temp, Reference temp and Z factor are all user defined, allowing support for many different types of sterilisation applications. Specification table for Sterilisation The definition of Fo/Po is the sterilisation/pasteurisation time in minutes required to destroy a stated number of organisms with a known z at temperature T. |
Batch | The Batch function allows the user to segment portions of data for further analysis. Batch controls include: - Start
- Stop
- Pause
- For viewing
- Resume and Abort
|
Print Support | Network printing from status, message and replay screens. Plus screen capture facility of process screens instantly using a basic USB standard PCL printer. |
Math Algorithms | All analog input channels have a math expression block. This is a fully user programmable 100 character free form math expression for each pen. Math calculations are available on all pens, one per input plus 12 extra pens for the SIREC D200 recorder. |
Miscellaneous | Optional customer ID Tagging (3 lines of up to 22 characters each line) |