The drive power is provided by a 24/48 V DC supply voltage commonly applied in mechanical engineering. PROFIBUS DP provides the full range of travel functions, such as
Travel to (absolute) end position, with velocity and adjustable acceleration
Travel around (relative) one path, in direction, with velocity and adjustable acceleration
Travel with (speed-controlled) controlled velocity and adjustable acceleration
Additional links:
Travel as soon as a time condition or logical condition is satisfied
Travel as long as a time condition or logical condition is satisfied
Travel and signal a previously defined byte combination from a particular position
Set floating actual value new synchronization of the actual value system (during movement of axis) to a fast input
Further functions:
Brake management for internal holding brake (300 W)
The integral retentive actual value memory provides characteristics similar to those of an absolute encoder.