Recommended continuous duty range of the complete fitting
? 30 m/s? (98.4 ft/s?) without resonance sharpness
Climatic class
In accordance with IEC EN 60721-3
Storage
1K5, but -40 ... +80 °C (1K5, but -40 ... +176 °F)
Transport
2K4, but -40 ... +80 °C (2K4, but -40 ... +176 °F)
Pneumatic data
Auxiliary power (air supply)
Compressed air, carbon dioxide (CO2), nitrogen (N), noble gases or cleaned natural gas
Pressure4)
1.4 ... 7 bar (20.3 ... 101.5 psi):
Air quality to ISO 8573-1
Solid particulate size and density
Class 2
Pressure dew point
Class 2 (min. 20 K (36 °F) below ambient temperature)
Oil content
Class 2
Unrestricted flow (DIN 1945)
Inlet air valve (ventilate actuator) 5)
2 bar (29 psi)
4.1 Nm?/h (18.1 USgpm)
4 bar (58 psi)
7.1 Nm?/h (31.3 USgpm)
6 bar (87 psi)
9.8 Nm?/h (43.1 USgpm)
Outlet air valve (deaerate actuator for all versions except fail in place)5)
2 bar (29 psi)
8.2 Nm?/h (36.1 USgpm)
4 bar (58 psi)
13.7 Nm?/h (60.3 USgpm)
6 bar (87 psi)
19.2 Nm?/h (84.5 USgpm)
Outlet air valve (deaerate actuator for fail in place version)
2 bar (29 psi)
4.3 Nm?/h (19.0 USgpm)
4 bar (58 psi)
7.3 Nm?/h (32.2 USgpm)
6 bar (87 psi)
9.8 Nm?/h (43.3 USgpm)
Throttle ratio
Adjustable up to ? : 1
Auxiliary power consumption in the controlled state
< 3.6 ·10-2 Nm?/h (0.158 USgpm)
Sound pressure
LAeq < 75 dB LAmax < 80 dB
Design
Mode of operation
Range of stroke (linear actuators)
3 ... 130 mm (0.12 ... 5.12 inch) (angle of rotation of positioner axis 16 ... 90°) Larger range of stroke on request.
Angle of rotation range (part-turn actuators)
30 ... 100°
Mounting type
On linear actuators
Using mounting kit 6DR4004-8V and where necessary with an additional lever arm 6DR4004-8L on actuators according to IEC 60534-6-1 (NAMUR) with ribs, bars or flat face.
On part-turn actuators
Using mounting kit 6DR4004-8D or TGX:16300-1556 on actuators with mounting plane according to VDI/VDE 3845 and IEC 60534-6-2. The actuator-specific mounting console can be ordered separately, see the selection and ordering data.
Weight, positioner without option modules or accessories
Einteilung nach Druckgeraterichtlinie (DGRL 2014/68/EU)
For gases of fluid group 1, complies with requirements of article 3, paragraph 3 (sound engineering practice SEP)
CE conformity
You can find the appropriate directives and standards, including the relevant versions, in the EC Declaration of Conformity on the Internet.
UL conformity
You can find the appropriate directives and standards, including the relevant versions, in the UL-CERTIFICATE OF COMPLIANCE on the Internet.
Explosion protection
Explosion protection according to ATEX/IECEx
Intrinsic safety "i"
For enclosure 6DR5..1-0D; 6DR5..2/3/6
II 2 D Ex ia IIIC T110°C Db
For enclosure 6DR5..0/1/2/3
II 2 G Ex ia IIC T6/T4 Gb
II 3 G Ex ic IIC T6/T4 Gc
Dust, protection with "t" enclosure
For enclosure 6DR5..1-0D/K; 6DR5..2/3/6
II 2 D Ex tb IIIC T100°C Db
Non-sparking "nA"
For enclosure 6DR5..1-0D; 6DR5..2/3
II 3 G Ex nA IIC T6/T4 Gc
Flameproof enclosure "d"
For enclosure 6DR5..5/6
II 2 G Ex d IIC T6/T4 Gb
Explosion protection in accordance with FM/CSA Suitable for installations according to NEC 500/NEC 505
Intrinsic safety "IS"
For enclosure 6DR5..0/1/2/3
IS / I, II / 1 / A-D
IS / 1 / (A)Ex / Ex ib / IIC, Gb
For enclosure 6DR5..1/2/3
IS / III / 1 / E-G
IS / 21 / (A)Ex / Ex ib / IIIC, Db, T110°C
Dust, protection with "DIP" enclosure
For enclosure 6DR5..1-0D/K; 6DR5..2/3/6
DIP / II, III / 1 / EFG / T6/T4
DIP / 21 / (A)Ex tb / IIIC / T100°C / Ta=85°C
Non-sparking "NI"
For enclosure 6DR5..1/2/3
NI / I / 2 / A-D
NI / 2 / (A)Ex nA / Ex ic / IIC, Gc
Flameproof enclosure "XP"
For enclosure 6DR5..5/6
FM
XP, CL.I, DIV.1, GP.ABCD
XP, CL.I, ZN. 1, (A)Ex d IIC
CSA
XP, CL.I, DIV.1, GP.CD
XP, CL.I, ZN. 1, Ex d IIC
Natural gas as driving medium
For technical specifications using natural gas as driving medium, see operating instructions.
1) Max. impact energy 1 Joule for enclosure with inspection window 6DR5..0 and 6DR5..1 or max. 2 Joule for 6DR5..3.
2) At ? -10 °C (? 14 °F) the display refresh rate of the display is limited. When using position feedback module, only T4 is permitted.
3) The following applies to order suffix (order code) -Z M40: -40 ... +80 °C (-40 ... +176 °F).
4) The following applies to fail in place: 3 ... 7 bar (43.5 ... 101.5 psi).
5) With Ex d version (6DR5..5-…) values are reduced by approximately 20%.
SIPART PS2 with and without HART
Basic electronics without explosion protection
Basic electronics with explosion protection Ex d
Basic electronics with explosion protection "ia"
Basic electronics with explosion protection "ic", "nA", "t"
Electrical specifications
Current input IW
Rated signal range
0/4 ... 20 mA
Test voltage
840 V DC, 1 s
Binary input BIN1 (terminals 9/10; electrically connected to the basic device)
Suitable only for floating contact; max. contact load < 5 ?A at 3 V
2-wire connection (terminals 6/8) 6DR50.. and 6DR53.. without HART 6DR51.. and 6DR52.. with HART
Current to maintain the auxiliary power supply
? 3.6 mA
Required load voltage UB (corresponds to ? at 20mA)
Without HART (6DR50..)
Typical
6.36 V (= 318 ?)
6.36 V (= 318 ?)
7.8 V (= 390 ?)
7.8 V (= 390 ?)
Max.
6.48 V (= 324 ?)
6.48 V (= 324 ?)
8.3 V (= 415 ?)
8.3 V (= 415 ?)
Without HART (6DR53..)
Typical
7.9 V (= 395 ?)
-
-
-
Max.
8.4 V (= 420 ?)
-
-
-
With HART (6DR51..)
Typical
6.6 V (= 330 ?)
6.6 V (= 330 ?)
-
-
Max.
6.72 V (= 336 ?)
6.72 V (= 336 ?)
-
-
With HART (6DR52..)
Typical
-
8.4 V (= 420 ?)
8.4 V (= 420 ?)
8.4 V (= 420 ?)
Max.
-
8.8 V (= 440 ?)
8.8 V (= 440 ?)
8.8 V (= 440 ?)
Static destruction limit
± 40 mA
± 40 mA
-
-
Effective internal capacitance Ci
Without HART
-
-
11 nF
"ic": 11 nF
With HART
-
-
11 nF
"ic": 11 nF
Effective internal inductance Li
Without HART
-
-
207 µH
"ic": 207 µH
With HART
-
-
310 µH
"ic": 310 µH
For connecting to circuits with the following peak values
-
-
Ui = 30 V Ii = 100 mA Pi = 1 W
"ic": Ui = 30 V Ii = 100 mA
"nA"/"t": Un ? 30 V In ? 100 mA
3-/4-wire connection (terminals 2/4 and 6/8) 6DR52.. with HART, explosion-protected 6DR53.. without HART, not explosion-protected)
Load voltage at 20 mA
? 0.2 V (= 10 ?)
? 0.2 V (= 10 ?)
? 1 V (= 50 ?)
? 1 V (= 50 ?)
Power supply UH
18 ... 35 V DC
18 ... 35 V DC
18 ... 30 V DC
18 ... 30 V DC
Current consumption IH
(UH -7.5 V)/2.4 k? [mA]
Effective internal capacitance Ci
-
-
22 nF
"ic": 22 nF
Effective internal inductance Li
-
-
0.12 mH
"ic": 0.12 mH
For connecting to circuits with the following peak values
-
-
Ui = 30 V Ii = 100 mA Pi = 1 W
"ic": Ui = 30 V Ii = 100 mA
"nA"/"t": Un ? 30 V In ? 100 mA
Electrical isolation
between UH and IW
between UH and IW
between UH und IW (2 intrinsically safe circuits)
between UH and IW
HART communication
HART version
7
PC parameter assignment software
SIMATIC PDM; supports all device objects. The software is not included in the scope of delivery.
SIPART PS2 with PROFIBUS PA/with FOUNDATION Fieldbus
Basic electronics without explosion protection
Basic electronics with explosion protection Ex d
Basic electronics with explosion protection "ia"
Basic electronics with explosion protection "ic", "nA", "t"
Electrical specifications
Auxiliary power supply bus circuit
Bus-powered
Bus voltage
9 ... 32 V
9 ... 32 V
9 ... 24 V
9 ... 32 V
For connecting to circuits with the following peak values
Bus connection with FISCO supply unit
Ui = 17.5 V Ii = 380 mA Pi = 5.32 W
"ic": Ui = 17.5 V Ii = 570 mA
"nA"/"t": Un ? 32 V
Bus connection with barrier
Ui = 24 V Ii = 250 mA Pi = 1.2 W
"ic": Ui = 32 V
"nA"/"t": Un ? 32 V
Effective internal capacitance Ci
-
-
Negligible
Negligible
Effective internal inductance Li
-
-
8 µH
"ic": 8 µH
Current consumption
11.5 mA ± 10 %
Additional error signal
0 mA
Safety shutdown can be activated with "jumper" (terminals 81/82)
electrically isolated from bus circuit and binary input
Input resistance
> 20 k?
Signal state "0" (shutdown active)
0 ... 4.5 V or unused
Signal state "1" (shutdown not active)
13 ... 30 V
For connecting to power supply with the following peak values
Ui = 30 V Ii = 100 mA Pi = 1 W
"nA": Un ? 30 V In ? 100 mA
"ic": Ui = 30 V Ii = 100 mA
Effective internal capacitance and inductance
-
-
Negligible
Negligible
Binary input BE1 for PROFIBUS (terminals 9/10); electrically connected to the bus circuit)
Bridged or connection to switching contact. Suitable only for floating contact; max. contact load < 5 µA at 3 V
Electrical isolation
For basic device without Ex protection and for basic device with Ex d
Electrical isolation between basic device and the input for safety shutdown, as well as the outputs of the option modules
For basic device Ex "ia"
The basic device and the input to the safety shutdown, as well as the outputs of the option modules, are separate, intrinsically safe circuits.
For basic device with explosion protection "ic", "nA", "t"
Electrical isolation between basic device and the input for safety shutdown, as well as the outputs of the option modules
Test voltage
840 V DC, 1 s
PROFIBUS PA communication
Communication
Layers 1 and +2 according to PROFIBUS PA, transmission technology according to IEC 61158-2; slave function; layer 7 (protocol layer) according to PROFIBUS DP, EN 50170 standard with the extended PROFIBUS functions (all data acyclic, manipulated variable, feedbacks and status also cyclic)
C2 connections
Four connections to master class 2 are supported; automatic connection setup 60 s after break in communication
Device profile
PROFIBUS PA profile B, version 3.02, more than 150 objects
Response time to master message
Typ. 10 ms
Device address
126 (when delivered)
PC parameter assignment software
SIMATIC PDM; supports all device objects. The software is not included in the scope of delivery.
FOUNDATION Fieldbus communication
Communications group and class
According to technical specification of the Fieldbus Foundation for H1 communication
Function blocks/functions
Group 3, Class 31PS (Publisher Subscriber) 1 Resource Block (RB2) 1 Analog Output Function Block (AO) 1 PID Function Block (PID) 1 Transducer Block (Standard Advanced Positioner Valve) Link Active Scheduler (LAS) function
Execution times of the blocks
AO: 30 ms PID: 40 ms
Physical layer profile
123, 511
FF registration
Tested with ITK 6.0
Device address
22 (when delivered)
Option modules
Without Ex protection/ with Ex protection Ex d
With explosion protection "ia"
With explosion protection "ic", "nA", "t"
Alarm unit
6DR4004-8A
6DR4004-6A
6DR4004-6A
3 binary output circuits
Alarm output A1: Terminals 41 and 42
Alarm output A2: Terminals 51 and 52
Alarm output: Terminals 31 and 32
Power supply UH
? 35 V
-
-
Signal state
High (not activated)
Conductive, R = 1 k?, +3/-1 % *)
? 2.1 mA
? 2.1 mA
Low *) (activated)
Blocked, IR < 60 µA
? 1.2 mA
? 1.2 mA
*) Low is also the status when the basic device is faulty or is without additional electrical power supply.
*) When used in the flameproof enclosure the current consumption must be limited to 10 mA per output.
Switching threshold with supply to EN 60947-5-6: UH = 8.2 V, Ri = 1 k?
Switching threshold with supply to EN 60947-5-6: UH = 8.2 V, Ri = 1 k?
For connecting to circuits with the following peak values
-
Ui = 15 V Ii = 25 mA Pi = 64 mW
"ic": Ui = 15 V Ii = 25 mA
"nA"/"t": Un ? 15 V
Effective internal capacitance Ci
-
5.2 nF
5.2 nF
Effective internal inductance Li
-
Negligible
Negligible
1 binary input circuit
Binary input BE2: Terminals 11 and 12, terminals 21 and 22 (bridge)
Electrically connected to the basic device
Signal state 0
Floating contact, open
Signal state 1
Floating contact, closed
Contact load
3 V, 5 ?A
Electrically isolated from the basic device
Signal state 0
? 4.5 V or open
Signal state 1
? 13 V
Natural resistance
? 25 k?
Static destruction limit
± 35 V
-
-
Connecting to circuits with the following peak values
-
Ui = 25.2 V
"ic": Ui = 25.2 V
"nA"/"t": Un ? 25.5 V
Effective internal capacitance Ci
-
Negligible
Negligible
Effective internal inductance Li
-
Negligible
Negligible
Electrical isolation
The 3 outputs, the input BE2 and the basic device are electrically isolated from each other
Test voltage
840 V DC, 1 s
Position feedback module
6DR4004-8J
6DR4004-6J
6DR4004-6J
DC output for position feedback
1 current output: Terminals 61 and 62
2-wire connection
Rated signal range
4 ... 20 mA, short-circuit proof
Total operating range
3.6 … 20.5 mA
Power supply UH
+12 … +35 V
+12 … +30 V
+12 … +30 V
External loads RB [k?]
? (UH [V] – 12 V)/I [mA]
Transmission error
? 0.3 %
Temperature influence effect
? 0.1 %/10 K (? 0.1 %/18 °F)
Resolution
? 0.1 %
Residual ripple
? 1 %
For connecting to circuits with the following peak values
-
Ui = 30 V Ii = 100 mA Pi = 1 W
"ic": Ui = 30 V Ii = 100 mA
"nA"/"t": Un ? 30 V In ? 100 mA Pn ? 1 W
Effective internal capacitance Ci
-
11 nF
11 nF
Effective internal inductance Li
-
Negligible
Negligible
Electrical isolation
Electrically isolated from the alarm option and safely isolated from the basic device
Test voltage
840 V DC, 1 s
Without Ex protection
With explosion protection "ia"
With explosion protection "ic", "nA", "t"
SIA module
Limit transmitter with slot-type initiators and alarm output
6DR4004-8G
6DR4004-6G
6DR4004-6G
2 slot-type initiators
Binary output (limit transmitter) A1: Terminals 41 and 42
Binary output (limit transmitter) A2: Terminals 51 and 52
Connection
2-wire system to EN 60947-5-6 (NAMUR), for switching amplifier to be connected on load side
Signal state High (not activated)
> 2.1 mA
Signal state Low (activated)
< 1.2 mA
2 slot-type initiators
Type SJ2-SN
Function
NC (normally closed)
Connecting to circuits with the following peak values
Rated voltage 8 V power consumption: ? 3 mA (limit not activated), ? 1 mA (limit activated)
Ui = 15 V Ii = 25 mA Pi = 64 mW
"ic": Ui = 15 V Ii = 25 mA
"nA": Un ? 15 V Pn ? 64 mW
Effective internal capacitance Ci
-
41 nF
41 nF
Effective internal inductance Li
-
100 µH
100 µH
1 alarm output
Binary output: Terminals 31 and 32
Connection
On switching amplifier according to EN 60947-5-6: (NAMUR), UH = 8.2 V, Ri = 1 k?).
Signal state High (not activated)
R = 1.1 k?
> 2.1 mA
> 2.1 mA
Signal state Low (activated)
R = 10 k?
< 1.2 mA
< 1.2 mA
Power supply UH
UH ? 35 V DC I ? 20 mA
-
-
Connecting to circuits with the following peak values
-
Ui = 15 V Ii = 25 mA Pi = 64 mW
"ic"/"nL": Ui = 15 V Ii = 25 mA
"nA": Un ? 15 V Pn ? 64 mW
Effective internal capacitance Ci
-
5.2 nF
5.2 nF
Effective internal inductance Li
-
Negligible
Negligible
Electrical isolation
The 3 outputs are electrically isolated from the basic device.
Test voltage
840 V DC, 1 s
Without Ex protection
With explosion protection "ia"
With explosion protection "ic", "t"
Limit value contact module
6DR4004-8K
6DR4004-6K
6DR4004-6K
Limit transmitter with mechanical switching contacts
2 limit value contacts
Binary output A1: Terminals 41 and 42
Binary output A2: Terminals 51 and 52
Max. switching current AC/DC
4 A
-
-
For connecting to circuits with the following peak values
-
Ui = 30 V Ii = 100 mA Pi = 750 mW
"ic": Ui = 30 V Ii = 100 mA
"t": Un = 30 V In = 100 mA
Effective internal capacitance Ci
-
Negligible
Negligible
Effective internal inductance Li
-
Negligible
Negligible
Max. switching voltage AC/DC
250 V/24 V
30 V DC
30 V DC
1 alarm output
Binary output: Terminals 31 and 32
Connection
On switching amplifier according to EN 60947-5-6: (NAMUR), UH = 8.2 V, Ri = 1 k?)
-
Signal state High (not activated)
R = 1.1 k?
> 2.1 mA
> 2.1 mA
Signal state Low (activated)
R = 10 k?
< 1.2 mA
< 1.2 mA
Auxiliary power
UH ? 35 V DC I ? 20 mA
-
-
Connecting to circuits with the following peak values
-
Ui = 15 V Ii = 25 mA Pi = 64 mW
"ic": Ui = 15 V Ii = 25 mA
"t": Un = 15 V In = 25 mA
Effective internal capacitance Ci
-
5.2 nF
5.2 nF
Effective internal inductance Li
-
Negligible
Negligible
Electrical isolation
The 3 outputs are electrically isolated from the basic device
Test voltage
3150 V DC, 2 s
Rated conditions altitude
Max. 2 000 m NN At altitudes over 2 000 m NN, use a suitable power supply
-
-
Without Ex protection
With explosion protection "ia"
With explosion protection "ic", "nA", "t"
EMC filter module
EMC filter module type C73451-A430-D23 is required for NCS sensor or an external potentiometer. External position sensor (potentiometer or NCS; as option) with the following peak values
Resistance of external potentiometer
10 k?
Peak values when supplied via the PROFIBUS basic device
-
Uo = 5 V Io = 75 mA static Io = 160 mA transient Po = 120 mW
Uo = 5 V Io = 75 mA Po = 120 mW
Peak values when supplied by other basic devices
-
Uo = 5 V Io = 100 mA Po = 33 mW Co = 1 ?F Lo = 1 mH
Uo = 5 V Io = 75 mA Po = 120 mW Co = 1 ?F Lo = 1 mH
Electrical isolation
Electrically connected to the basic device
Without Ex protection
With explosion protection "ia"
With explosion protection "ic", "nA"
NCS sensor
Position range
Linear actuator 6DR4004-.N.20
3 ... 14 mm (0.12 ... 0.55")
Linear actuator 6DR4004-.N.30
10 ... 130 mm (0.39 ... 5.12"); up to 200 mm (7.87") on request
Part-turn actuator
30° ... 100°
Linearity (after correction by positioner)
Linear actuator
± 1 %
Part-turn actuator
± 1 %
Hysteresis
± 0.2 %
Temperature influence (range: Rotation angle 120° or stroke 14 mm)
? 0.1 %/10 K (? 0.1 %/18 °F) for -20 ... +90 °C (-4 ... +194 °F) ? 0.2 %/10 K (? 0.2 %/18 °F) for -40 ... -20 °C (-40 ... -4 °F)
Climatic class
In accordance with IEC EN 60721-3
Storage
1K5, but -40 ... +90 °C (1K5, but -40 ... +194 °F)
Transport
2K4, but -40 ... +90 °C (2K4, but -40 ... +194 °F)
Continuous working temperature
-40 °C ... +90 °C (-40 °F ... +194 °F)
-
-
Vibration resistance
Harmonic oscillations (sine) according to IEC 60068-2-6
IP68 according to IEC EN 60529; NEMA 4X / Encl. Type 4X
For connecting to circuits with the following peak values
-
Ui = 5 V Ii = 160 mA Pi = 120 mW
Ui = 5 V
Effective internal capacitance Ci
-
180 nF
180 nF
Effective internal inductance Li
-
922 µH
922 µH
Explosion protection according to ATEX/IECEx
-
Intrinsic safety "ia": II 2 G Ex ia IIC T6/T4 Gb
Intrinsic safety "ic": II 3 G Ex ic IIC T6/T4 Gc
Non-sparking "nA": II 3 G Ex nA IIC T6/T4 Gc
Explosion protection acc. to FM
-
Intrinsic safety "ia": IS, Class I, Division 1, ABCD IS, Class I, Zone 1, AEx ib, IIC
Non-sparking "nA": NI, Class I, Division 2, ABCD NI, Class I, Zone 2, AEx nA, IIC
Permissible ambient temperature
ATEX/IECEx
-
T4: -40 ... +90 °C (-40 ... +194 °F) T6: -40 ... +70 °C (-40 ... +158 °F)
FM/CSA
-
T4: -40 ... +85 °C (-40 ... +185 °F) T6: -40 ... +70 °C (-40 ... +158 °F)
skener.ru
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ