Measurement of | Mass flow [kg/s (lb/min)], volume flow [l/s (gpm)], fraction [%], °Brix, density [kg/m3 (lbs/ft3)], temperature [°C (°F)] |
Current output | Classified Ex ia, selectable as active or passive outputs. Default setting is active mode. |
Current | 0 … 20 mA or 4 … 20 mA |
Load | < 350 ? |
Time constant | 0 … 99.9 s adjustable |
Current characteristics | |
Active mode | Uo = 24 V, Io = 82 mA, Po = 0.5 W, Co = 125 nF, Lo = 2.5 mH |
Passive mode (max input from external barrier) | Ui = 30 V, Ii = 100 mA, Pi = 0.75 W, Ci = 52 nF, Li = 100 ?H |
Digital output | |
Frequency | 0 … 10 kHz, 50 % duty cycle |
Time constant | 0.1 … 30 s adjustable |
Passive | 6 … 30 V DC, max. 110 mA, 1 k? ? Rload ? 10 k? |
Output characteristics | |
Active mode | Not available |
Passive mode (max input from external barrier) | Ui = 30 V, Ii = 100 mA, Pi = 0.75 W, Ci = 52 nF, Li = 100 ?H |
Relay | |
Type | Change-over relay |
Load | 30 V/100 mA |
Functionality | Error level, error number, limit, direction |
Output characteristics | Ui = 30 V, Ii = 100 mA, Pi = 0.75 W, Ci = 0 nF, Li = 0 mH |
Digital input | 11 … 30 V DC (Ri = 13.6 k?) |
Functionality | Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output |
Output characteristics | Ui = 30 V, Ii = 3.45 mA, Pi = 0.10 W, Ci = 0 nF, Li = 0 mH |
Galvanic isolation | All inputs and outputs are galvanically isolated. Isolation voltage: - 500 V to supply
- 50 V between outputs
|
Cut-off | |
Low-flow | 0 … 9.9 % of maximum flow |
Empty pipe | Detection of empty sensor |
Density | 0 … 2.9 g/cm3 |
Totalizer | Two eight-digit counters for forward, net or reverse flow |
Display | - Background illumination with alphanumerical text, 3 ? 20 characters to indicate flow rate, totalized values, settings and faults. Time constant as current output
- Reverse flow indicated by negative sign
|
Zero point adjustment | Via keypad or remote via digital input |
Ambient temperature | |
Operation | -20 … +50°C (-4 … +122 °F) |
Storage | -40 … +70°C (-40 … +158 °F) (Humidity max. 95 %) |
Communication | Add-on modules: HART, PROFIBUS PA, FOUNDATION Fieldbus H1 |
HART | |
Active mode | Uo = 6.88 V, Io = 330 mA, Po = 0.57 W, Co = 20 nF, Lo = 100 ?H |
Passive mode (max input from external barrier) | Ui = 10 V, Ii = 200 mA, Pi = 0.5 W, Ci = 0 nF, Li = 0 ?H |
PROFIBUS PA | |
Active mode | Not available |
Passive mode | Ui = 17.5 V, Ii = 380 mA, Pi = 5.32 W, Ci = 5 nF, Li = 10 ?H |
FOUNDATION Fieldbus H1 | |
Active mode | Not available |
Passive mode | Ui = 17.5 V, Ii = 380 mA |
Enclosure | |
Material | Stainless steel AISI 316/1.4435 |
Rating | - Compact mounted on sensor: IP67/NEMA 4X
- Remote mounted: IP65
|
Load | 18 … 1000 Hz random, 1.14 g RMS, in all directions |
Supply voltage | |
24 V AC | |
| 20 … 30 V AC |
| 6 VA IN = 250 mA, IST = 2 A (30 ms) |
| The power supply shall be from a safety isolating transformer. Maximal cable core is 1.5 mm2. |
24 V DC | |
| 18 … 30 V DC |
| 6 W IN = 250 mA, IST = 2 A (30 ms) |
| The power supply shall be from a safety isolating transformer. Maximal cable core is 1.5 mm2. |
EMC performance | |
Emission | EN 55011/CISPR-11 (Class A) |
Immunity | EN/IEC 61326-1 (Industry) |
NAMUR | Within the value limits according to "General requirements" with error criteria A in accordance with NE 21 |
Ex approval | ATEX, EAC Ex: Ex d e ib [ia Ga] IIC T4 Gb |