SCALANCE X-200 managed

Order number

6GK5204-2BB10-2AA3

6GK5204-2BB11-2AA3

6GK5204-2BB10-2CA2

Product type designation

SCALANCE X204-2

SCALANCE X204-2FM

SCALANCE X204-2TS

Transmission rate

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces for communication integrated

 

 

 

Number of electrical connections

 

 

 

  • ? for network components or terminal equipment

4

4

4

Number of 100 Mbit/s ST(BFOC) ports

 

 

 

  • ? for multimode

2

2

2

Number of 100 Mbit/s SC ports

 

 

 

  • ? for multimode

0

0

0

Number of 1000 Mbit/s LC ports

 

 

 

  • ? for multimode

0

0

0

  • ? for single mode (LD)

0

0

0

Interfaces others

 

 

 

Number of electrical connections

 

 

 

  • ? for signaling contact

1

1

1

  • ? for power supply

1

1

1

  • ? for redundant voltage supply

1

1

1

Type of electrical connection

 

 

 

  • ? for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

design of the removable storage

 

 

 

  • ? C-PLUG

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

Operating voltage of the signaling contacts

 

 

 

  • ? at DC Rated value

24 V

24 V

24 V

Operating current of the signaling contacts

 

 

 

  • ? at DC maximum

0.1 A

0.1 A

0.05 A

Supply voltage, current consumption, power loss

 

 

 

Type of voltage of the supply voltage

DC

DC

DC

Supply voltage

 

 

 

  • ? external

24 V

24 V

12 V

  • ? external

18 ... 32 V

18 ... 32 V

10 ... 30 V

Supply voltage at DC

24 V

  • ? rated value

10 ... 30 V

Product component fusing at power supply input

Yes

Yes

Yes

Fuse protection type at input for supply voltage

0.6 A / 60 V

0.6 A / 60 V

3 A / 32 V

Consumed current maximum

0.265 A

0.265 A

0.6 A

Power loss [W]

 

 

 

  • ? at DC at 24 V

6.36 W

6.36 W

6.6 W

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

-40 ... +60 °C

-40 ... +60 °C

-40 ... +70 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? Note

If the IE switch X-204-2TS is installed horizontally, a maximum ambient temperature of +40 °C is permitted

Relative humidity

 

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Protection class IP

IP30

IP30

IP20

Design, dimensions and weight

 

 

 

Design

compact

compact

compact

Width

60 mm

60 mm

60 mm

Height

125 mm

125 mm

125 mm

Depth

124 mm

124 mm

124 mm

Net weight

0.78 kg

0.78 kg

0.78 kg

Product feature conformal coating

Yes

Mounting type

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

  • ? S7-300 rail mounting

Yes

Yes

Yes

  • ? S7-1500 rail mounting

No

No

No

Product properties, functions, components general

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

Product function

 

 

 

  • ? CLI

Yes

Yes

Yes

  • ? web-based management

Yes

Yes

Yes

  • ? MIB support

Yes

Yes

Yes

  • ? TRAPs via email

Yes

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

Yes

  • ? Port mirroring

Yes

Yes

Yes

  • ? multiport mirroring

No

No

No

  • ? with IRT PROFINET IO switch

No

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

Yes

  • ? switch-managed

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? Telnet

Yes

Yes

Yes

  • ? HTTP

Yes

Yes

Yes

  • ? HTTPS

Yes

Yes

Yes

  • ? TFTP

Yes

Yes

Yes

  • ? FTP

Yes

Yes

Yes

  • ? BOOTP

No

No

No

  • ? DCP

Yes

Yes

Yes

  • ? LLDP

Yes

Yes

Yes

Identification & maintenance function

 

 

 

  • ? I&M0 - device-specific information

Yes

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? SNMP v1

Yes

Yes

Yes

  • ? SNMP v2

Yes

Yes

Yes

  • ? SNMP v3

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

Product function

 

 

 

  • ? Port diagnostics

Yes

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

Yes

  • ? Statistics packet type

Yes

Yes

Yes

  • ? Error statistics

Yes

Yes

Yes

Product functions DHCP

 

 

 

Product function

 

 

 

  • ? DHCP client

Yes

Yes

Yes

Product functions Redundancy

 

 

 

Product function

 

 

 

  • ? Ring redundancy

Yes

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

No

No

No

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Product function

 

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

  • ? Parallel Redundancy Protocol (PRP)/operation in the PRP-network

Yes

Yes

  • ? Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)

No

No

  • ? Passive listening

Yes

Yes

Yes

Product functions Security

 

 

 

Protocol is supported

 

 

 

  • ? SSH

Yes

Yes

Yes

Product functions Time

 

 

 

Product function

 

 

 

  • ? SICLOCK support

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? NTP

No

No

No

  • ? SNTP

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X

EN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • ? for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-4:2001

EN 61000-6-4:2001

EN 61000-6-2

Certificate of suitability CE marking

Yes

Yes

Yes

Certificate of suitability

EN 61000-6-4:2001

EN 61000-6-4:2001

EN 61000-6-2, EN 61000-6-4

  • ? C-Tick

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

Yes

  • ? Railway application in accordance with EN 50121-4

Yes

  • ? Railway application in accordance with EN 50124-1

No

No

No

  • ? KC approval

Yes

Yes

Yes

Marine classification association

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

Yes

No

  • ? Bureau Veritas (BV)

Yes

No

  • ? Det Norske Veritas (DNV)

Yes

Yes

  • ? Germanische Lloyd (GL)

Yes

No

  • ? Lloyds Register of Shipping (LRS)

Yes

Yes

  • ? Nippon Kaiji Kyokai (NK)

Yes

Yes

  • ? Polski Rejestr Statkow (PRS)

Yes

Yes

  • ? Royal Institution of Naval Architects (RINA)

No

Yes

MTBF at 40 °C

74.64 y

87.19 y

72.99 y


Order number

6GK5204-2BC10-2AA3

6GK5204-2BC10-2CA2

Product type designation

SCALANCE X204-2LD

SCALANCE X204-2LD TS

Transmission rate

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces for communication integrated

 

 

Number of electrical connections

 

 

  • ? for network components or terminal equipment

4

4

Number of 100 Mbit/s ST(BFOC) ports

 

 

  • ? for single mode (LD)

2

2

Number of 100 Mbit/s SC ports

 

 

  • ? for multimode

0

0

Number of 1000 Mbit/s LC ports

 

 

  • ? for multimode

0

0

  • ? for single mode (LD)

0

0

Interfaces others

 

 

Number of electrical connections

 

 

  • ? for signaling contact

1

1

  • ? for power supply

1

1

  • ? for redundant voltage supply

1

1

Type of electrical connection

 

 

  • ? for signaling contact

2-pole terminal block

2-pole terminal block

  • ? for power supply

4-pole terminal block

4-pole terminal block

design of the removable storage

 

 

  • ? C-PLUG

Yes

Yes

Signal-Inputs/outputs

 

 

Operating voltage of the signaling contacts

 

 

  • ? at DC Rated value

24 V

24 V

Operating current of the signaling contacts

 

 

  • ? at DC maximum

0.1 A

0.05 A

Supply voltage, current consumption, power loss

 

 

Type of voltage of the supply voltage

DC

DC

Supply voltage

 

 

  • ? external

24 V

12 V

  • ? external

18 ... 32 V

10 ... 30 V

Supply voltage at DC

24 V

  • ? rated value

10 ... 30 V

Product component fusing at power supply input

Yes

Yes

Fuse protection type at input for supply voltage

0.6 A / 60 V

3 A / 32 V

Consumed current maximum

0.265 A

0.6 A

Power loss [W]

 

 

  • ? at DC at 24 V

6.36 W

6.6 W

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • ? during operation

-40 ... +60 °C

-40 ... +70 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

  • ? Note

If the IE switch X-204-2LD TS is installed horizontally a maximum ambient temperature of +40 °C is permitted

Relative humidity

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

Protection class IP

IP30

IP20

Design, dimensions and weight

 

 

Design

compact

compact

Width

60 mm

60 mm

Height

125 mm

125 mm

Depth

124 mm

124 mm

Net weight

0.78 kg

0.78 kg

Product feature conformal coating

Yes

Mounting type

  • ? 35 mm DIN rail mounting

Yes

Yes

  • ? wall mounting

Yes

Yes

  • ? S7-300 rail mounting

Yes

Yes

  • ? S7-1500 rail mounting

No

No

Product properties, functions, components general

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

 

 

Product function

 

 

  • ? CLI

Yes

Yes

  • ? web-based management

Yes

Yes

  • ? MIB support

Yes

Yes

  • ? TRAPs via email

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

  • ? Port mirroring

Yes

Yes

  • ? multiport mirroring

No

No

  • ? with IRT PROFINET IO switch

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

  • ? switch-managed

Yes

Yes

Protocol is supported

 

 

  • ? Telnet

Yes

Yes

  • ? HTTP

Yes

Yes

  • ? HTTPS

Yes

Yes

  • ? TFTP

Yes

Yes

  • ? FTP

Yes

Yes

  • ? BOOTP

No

No

  • ? DCP

Yes

Yes

  • ? LLDP

Yes

Yes

Identification & maintenance function

 

 

  • ? I&M0 - device-specific information

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Protocol is supported

 

 

  • ? SNMP v1

Yes

Yes

  • ? SNMP v2

Yes

Yes

  • ? SNMP v3

Yes

Yes

Product functions Diagnosis

 

 

Product function

 

 

  • ? Port diagnostics

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

  • ? Statistics packet type

Yes

Yes

  • ? Error statistics

Yes

Yes

Product functions DHCP

 

 

Product function

 

 

  • ? DHCP client

Yes

Yes

Product functions Redundancy

 

 

Product function

 

 

  • ? Ring redundancy

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

No

No

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Product function

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

  • ? Parallel Redundancy Protocol (PRP)/operation in the PRP-network

Yes

  • ? Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)

No

  • ? Passive listening

Yes

Yes

Product functions Security

 

 

Protocol is supported

 

 

  • ? SSH

Yes

Yes

Product functions Time

 

 

Product function

 

 

  • ? SICLOCK support

Yes

Yes

Protocol is supported

 

 

  • ? NTP

No

No

  • ? SNTP

Yes

Yes

Standards, specifications, approvals

 

 

Standard

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • ? for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • ? for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-2

EN 61000-6-2

Certificate of suitability CE marking

Yes

Yes

Certificate of suitability

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

  • ? C-Tick

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

Yes

  • ? Railway application in accordance with EN 50121-4

Yes

  • ? Railway application in accordance with EN 50124-1

No

No

  • ? KC approval

Yes

Yes

Marine classification association

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

No

No

  • ? Bureau Veritas (BV)

Yes

No

  • ? Det Norske Veritas (DNV)

Yes

Yes

  • ? Germanische Lloyd (GL)

Yes

No

  • ? Lloyds Register of Shipping (LRS)

Yes

Yes

  • ? Nippon Kaiji Kyokai (NK)

Yes

Yes

  • ? Polski Rejestr Statkow (PRS)

Yes

Yes

  • ? Royal Institution of Naval Architects (RINA)

No

Yes

MTBF at 40 °C

74.64 y

85.01 y


Order number

6GK5206-1BB10-2AA3

6GK5206-1BC10-2AA3

6GK5208-0BA10-2AA3

Product type designation

SCALANCE X206-1

SCALANCE X206-1LD

SCALANCE X208

Transmission rate

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces for communication integrated

 

 

 

Number of electrical connections

 

 

 

  • ? for network components or terminal equipment

6

6

8

Number of 100 Mbit/s ST(BFOC) ports

 

 

 

  • ? for multimode

1

  • ? for single mode (LD)

1

Number of 100 Mbit/s SC ports

 

 

 

  • ? for multimode

0

0

0

Number of 1000 Mbit/s LC ports

 

 

 

  • ? for multimode

0

0

0

  • ? for single mode (LD)

0

0

0

Interfaces others

 

 

 

Number of electrical connections

 

 

 

  • ? for signaling contact

1

1

1

  • ? for power supply

1

1

1

  • ? for redundant voltage supply

1

1

1

Type of electrical connection

 

 

 

  • ? for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

design of the removable storage

 

 

 

  • ? C-PLUG

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

Operating voltage of the signaling contacts

 

 

 

  • ? at DC Rated value

24 V

24 V

24 V

Operating current of the signaling contacts

 

 

 

  • ? at DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

Type of voltage of the supply voltage

DC

DC

DC

Supply voltage

 

 

 

  • ? external

24 V

24 V

24 V

  • ? external

18 ... 32 V

18 ... 32 V

18 ... 32 V

Product component fusing at power supply input

Yes

Yes

Yes

Fuse protection type at input for supply voltage

0.6 A / 60 V

0.6 A / 60 V

0.6 A / 60 V

Consumed current maximum

0.22 A

0.2 A

0.185 A

Power loss [W]

 

 

 

  • ? at DC at 24 V

5.28 W

5.28 W

3.84 W

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • ? during operation

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

Relative humidity

 

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

95 %

Protection class IP

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

Design

compact

compact

compact

Width

60 mm

60 mm

60 mm

Height

125 mm

125 mm

125 mm

Depth

124 mm

124 mm

124 mm

Net weight

0.78 kg

0.78 kg

0.78 kg

Mounting type

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

  • ? S7-300 rail mounting

Yes

Yes

Yes

  • ? S7-1500 rail mounting

No

No

No

Product properties, functions, components general

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

Product function

 

 

 

  • ? CLI

Yes

Yes

Yes

  • ? web-based management

Yes

Yes

Yes

  • ? MIB support

Yes

Yes

Yes

  • ? TRAPs via email

Yes

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

Yes

  • ? Port mirroring

Yes

Yes

Yes

  • ? multiport mirroring

No

No

No

  • ? with IRT PROFINET IO switch

No

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

Yes

  • ? switch-managed

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? Telnet

Yes

Yes

Yes

  • ? HTTP

Yes

Yes

Yes

  • ? HTTPS

Yes

Yes

Yes

  • ? TFTP

Yes

Yes

Yes

  • ? FTP

Yes

Yes

Yes

  • ? BOOTP

No

No

No

  • ? DCP

Yes

Yes

Yes

  • ? LLDP

Yes

Yes

Yes

Identification & maintenance function

 

 

 

  • ? I&M0 - device-specific information

Yes

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? SNMP v1

Yes

Yes

Yes

  • ? SNMP v2

Yes

Yes

Yes

  • ? SNMP v3

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

Product function

 

 

 

  • ? Port diagnostics

Yes

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

Yes

  • ? Statistics packet type

Yes

Yes

Yes

  • ? Error statistics

Yes

Yes

Yes

Product functions DHCP

 

 

 

Product function

 

 

 

  • ? DHCP client

Yes

Yes

Yes

Product functions Redundancy

 

 

 

Product function

 

 

 

  • ? Ring redundancy

Yes

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

No

No

No

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Product function

 

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

  • ? Parallel Redundancy Protocol (PRP)/operation in the PRP-network

Yes

Yes

Yes

  • ? Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)

No

No

No

  • ? Passive listening

Yes

Yes

Yes

Product functions Security

 

 

 

Protocol is supported

 

 

 

  • ? SSH

Yes

Yes

Yes

Product functions Time

 

 

 

Product function

 

 

 

  • ? SICLOCK support

Yes

Yes

Yes

Protocol is supported

 

 

 

  • ? NTP

No

No

No

  • ? SNTP

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • ? for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • ? for interference immunity

EN 61000-6-2:2001

EN 61000-6-2

EN 61000-6-2

Certificate of suitability CE marking

Yes

Yes

Yes

Certificate of suitability

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

  • ? C-Tick

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

No

  • ? KC approval

Yes

Yes

Yes

Marine classification association

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

Yes

No

Yes

  • ? Bureau Veritas (BV)

Yes

Yes

Yes

  • ? Det Norske Veritas (DNV)

Yes

Yes

Yes

  • ? Germanische Lloyd (GL)

Yes

Yes

Yes

  • ? Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

  • ? Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

  • ? Polski Rejestr Statkow (PRS)

Yes

Yes

Yes

  • ? Royal Institution of Naval Architects (RINA)

No

No

No

MTBF at 40 °C

78.71 y

78.71 y

83.71 y


Order number

6GK5212-2BB00-2AA3

6GK5212-2BC00-2AA3

6GK5216-0BA00-2AA3

6GK5224-0BA00-2AA3

Product type designation

SCALANCE X212-2

SCALANCE X212-2LD

SCALANCE X216

SCALANCE X224

Transmission rate

 

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces for communication integrated

 

 

 

 

Number of electrical connections

 

 

 

 

  • ? for network components or terminal equipment

12

12

16

24

Number of 100 Mbit/s ST(BFOC) ports

 

 

 

 

  • ? for multimode

2

  • ? for single mode (LD)

2

Number of 100 Mbit/s SC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Number of 1000 Mbit/s LC ports

 

 

 

 

  • ? for multimode

0

0

0

0

  • ? for single mode (LD)

0

0

0

0

Interfaces others

 

 

 

 

Number of electrical connections

 

 

 

 

  • ? for signaling contact

1

1

1

1

  • ? for power supply

1

1

1

1

  • ? for redundant voltage supply

1

1

1

1

Type of electrical connection

 

 

 

 

  • ? for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

design of the removable storage

 

 

 

 

  • ? C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

 

Operating voltage of the signaling contacts

 

 

 

 

  • ? at DC Rated value

24 V

24 V

24 V

24 V

Operating current of the signaling contacts

 

 

 

 

  • ? at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of voltage of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • ? external

24 V

24 V

24 V

24 V

  • ? external

18 ... 32 V

18 ... 32 V

18 ... 32 V

18 ... 32 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Fuse protection type at input for supply voltage

1.1 A / 33 V

1.1 A / 33 V

1.1 A / 33 V

1.1 A / 33 V

Consumed current maximum

0.33 A

0.33 A

0.24 A

0.35 A

Power loss [W]

 

 

 

 

  • ? at DC at 24 V

7.92 W

7.92 W

5.76 W

8.4 W

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

-40 ... +60 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

Relative humidity

 

 

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

 

Design

compact

compact

compact

compact

Width

120 mm

120 mm

120 mm

180 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

124 mm

124 mm

124 mm

124 mm

Net weight

1.2 kg

1.2 kg

1.2 kg

1.6 kg

Mounting type

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

Yes

  • ? S7-300 rail mounting

Yes

Yes

Yes

Yes

  • ? S7-1500 rail mounting

No

No

No

No

Product properties, functions, components general

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

100

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

 

Product function

 

 

 

 

  • ? CLI

Yes

Yes

Yes

Yes

  • ? web-based management

Yes

Yes

Yes

Yes

  • ? MIB support

Yes

Yes

Yes

Yes

  • ? TRAPs via email

Yes

Yes

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

Yes

Yes

  • ? Port mirroring

Yes

Yes

Yes

Yes

  • ? multiport mirroring

No

No

No

No

  • ? with IRT PROFINET IO switch

No

No

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • ? switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? Telnet

Yes

Yes

Yes

Yes

  • ? HTTP

Yes

Yes

Yes

Yes

  • ? HTTPS

Yes

Yes

Yes

Yes

  • ? TFTP

Yes

Yes

Yes

Yes

  • ? FTP

Yes

Yes

Yes

Yes

  • ? BOOTP

No

No

No

No

  • ? DCP

Yes

Yes

Yes

Yes

  • ? LLDP

Yes

Yes

Yes

Yes

Identification & maintenance function

 

 

 

 

  • ? I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SNMP v1

Yes

Yes

Yes

Yes

  • ? SNMP v2

Yes

Yes

Yes

Yes

  • ? SNMP v3

Yes

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

 

Product function

 

 

 

 

  • ? Port diagnostics

Yes

Yes

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

Yes

Yes

  • ? Statistics packet type

Yes

Yes

Yes

Yes

  • ? Error statistics

Yes

Yes

Yes

Yes

Product functions DHCP

 

 

 

 

Product function

 

 

 

 

  • ? DHCP client

Yes

Yes

Yes

Yes

Product functions Redundancy

 

 

 

 

Product function

 

 

 

 

  • ? Ring redundancy

Yes

Yes

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

No

No

No

No

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

 

 

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? Parallel Redundancy Protocol (PRP)/operation in the PRP-network

Yes

Yes

Yes

Yes

  • ? Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)

No

No

No

No

  • ? Passive listening

Yes

Yes

Yes

Yes

Product functions Security

 

 

 

 

Protocol is supported

 

 

 

 

  • ? SSH

Yes

Yes

Yes

Yes

Product functions Time

 

 

 

 

Product function

 

 

 

 

  • ? SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? NTP

No

No

No

No

  • ? SNTP

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • ? for hazardous zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • ? for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • ? for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

  • ? for interference immunity

EN 61000-6-2:2001

EN 61000-6-2:2001

EN 61000-6-2:2001

EN 61000-6-2:2001

Certificate of suitability CE marking

Yes

Yes

Yes

Yes

Certificate of suitability

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

  • ? C-Tick

Yes

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

No

No

  • ? KC approval

Yes

Yes

Yes

Yes

Marine classification association

 

 

 

 

  • ? American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

  • ? Bureau Veritas (BV)

Yes

Yes

Yes

Yes

  • ? Det Norske Veritas (DNV)

Yes

Yes

Yes

Yes

  • ? Germanische Lloyd (GL)

No

No

No

No

  • ? Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

  • ? Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes

  • ? Polski Rejestr Statkow (PRS)

Yes

Yes

Yes

Yes

  • ? Royal Institution of Naval Architects (RINA)

Yes

Yes

Yes

Yes

MTBF at 40 °C

51.18 y

51.18 y

52.07 y

45.87 y


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Introduction Industrial Ethernet Introduction Data communication Communication overview Topologies Network selection criteria Cabling Technology Media Converters Layer 2 Switches Overview Compact Switch Modules SCALANCE X-000 unmanaged SCALANCE X-100 unmanaged SCALANCE X-200 managed SCALANCE X-200 managed SIPLUS SCALANCE X-200 managed SCALANCE X-200PRO managed SCALANCE XB-200 managed SCALANCE XC-200 managed SCALANCE XP-200 managed SCALANCE XF-200 managed SCALANCE X200RNA managed SCALANCE X-200IRT managed SCALANCE X-300 managed RUGGEDCOM i800 unmanaged or managed RUGGEDCOM RS900 / M900 managed RUGGEDCOM RS950 RNA managed RUGGEDCOM RSG2100 / M2100 managed RUGGEDCOM RSG2200 / M2200 managed RUGGEDCOM RSG2300 managed RUGGEDCOM RSG2488 managed RUGGEDCOM RS8000 managed RUGGEDCOM Accessories RUGGEDCOM Technology Modules Layer 3 switches / routers Serial Device Servers Power over Ethernet Injector Industrial Ethernet Security System Interfaces SCALANCE Accessories RUGGEDCOM Accessories Network management and diagnostics Network Transitions Industrial Network Services Partner Solutions PROFINET PROFIBUS AS-Interface IO-Link Industrial Wireless Communication Industrial Remote Communication Industrial Security Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика